CADEN
Cart

Hybrid Motor Starters

150 Items
2903902
ELR H5-IES-PT- 24DC/500AC-0,6 - Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and push-in connection
Not in stock
2903908
ELR H5-I-PT- 24DC/500AC-0,6 - Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
Not in stock
2903910
ELR H5-I-PT- 24DC/500AC-2 - Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
Not in stock
2903914
ELR H3-IES-PT- 24DC/500AC-0,6 - Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.
Not in stock
2903916
ELR H3-IES-PT- 24DC/500AC-2 - Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.
Not in stock
2903920
ELR H3-I-PT- 24DC/500AC-0,6 - Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
Not in stock
2903922
ELR H3-I-PT- 24DC/500AC-2 - Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
Not in stock
2904473
EM-D-8/4-24DC-IFS - For more complex applications with Interface system devices (IFS), the extension module offers digital inputs and outputs for processing additional signals in the field. Easy connection to IFS gateway via the DIN rail connector as the slave.
Not in stock
2904494
BRIDGE-PT 6 - 3-phase loop bridge for 6 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m
Not in stock
2904495
BRIDGE-PT 7 - 3-phase loop bridge for 7 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m
Not in stock
2904496
BRIDGE-PT 8 - 3-phase loop bridge for 8 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m
10 Manufacturer stock
Canada
10
2904497
BRIDGE-PT 9 - 3-phase loop bridge for 9 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m
Not in stock
2904498
BRIDGE-PT 10 - 3-phase loop bridge for 10 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m
Not in stock
2905138
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.
Not in stock
2905139
ELR H5-IES-PT/500AC-3-IFS - Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.
50 Manufacturer stock
Canada
50
2905140
ELR H5-IES-PT/500AC-9-IFS - Networkable hybrid motor starter for reversing of 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.
Not in stock
2905143
Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 9 A, emergency stop function, adjustable overload shutdown, and Push-in connection, DIN rail connector provided.
Not in stock
2905513
ELR H5-I-SC-24DC/500AC-2-L - Hybrid motor starter, for reversing 3~ AC motors up to 550 V AC/2.4 A, 24 V DC input, class 10 tripping characteristic, overload function, without symmetry monitoring, and without phase failure and underload detection. 1-phase motors can be switched.
Not in stock
2906058
ELR H5-IES-PT-24DC/500AC-06-T - Hybrid motor starter; functions: Start motor, Reverse motor, Motor protection, Emergency stop, Higher resistance to transient voltages; input: 24 V DC; output: 3~, 500 V AC, 600 mA; connection method: Push-in connection
Not in stock
2906061
ELR H3-IES-PT-24DC/500AC-06-T - Hybrid motor starter; functions: Start motor, Motor protection, Emergency stop, Higher resistance to transient voltages; input: 24 V DC; output: 3~, 500 V AC, 600 mA; connection method: Push-in connection
Not in stock