Select values from the drop down lists or make appropriate selections to configure the part number.
Manifold with Stainless Steel Plate
-- Pick an Option --
S
Model
-- Pick an Option --
51S (EX260)
SI Unit
-- Pick an Option --
0 (without SI Unit)
QA (Positive Common, NPN; DeviceNet®; 32 Outputs; M12 Connector)
QAN (Negative Common, PNP; DeviceNet®; 32 Outputs; M12 Connector)
QB (Positive Common, NPN; DeviceNet®; 16 Outputs; M12 Connector)
QBN (Negative Common, PNP; DeviceNet®; 16 Outputs; M12 Connector)
NA (Positive Common, NPN; PROFIBUS DP; 32 Outputs; M12 Connector)
NAN (Negative Common, PNP; PROFIBUS DP; 32 Outputs; M12 Connector)
NB (Positive Common, NPN; PROFIBUS DP; 16 Outputs; M12 Connector)
NBN (Negative Common, PNP; PROFIBUS DP; 16 Outputs; M12 Connector)
NC (Positive Common, NPN; PROFIBUS DP; 32 Outputs; D-sub Connector)
NCN (Negative Common, PNP; PROFIBUS DP; 32 Outputs; D-sub Connector)
ND (Positive Common, NPN; PROFIBUS DP; 16 Outputs; D-sub Connector)
NDN (Negative Common, PNP; PROFIBUS DP; 16 Outputs; D-sub Connector)
VA (Positive Common, NPN; CC-Link; 32 Outputs; M12 Connector)
VAN Negative Common, PNP; CC-Link; 32 Outputs; M12 Connector)
VB (Positive Common, NPN; CC-Link; 16 Outputs; M12 Connector)
VBN (Negative Common, PNP; CC-Link; 16 Outputs; M12 Connector)
DA (Positive Common, NPN; EtherCAT®; 32 Outputs; M12 Connector)
DAN (Negative Common, PNP; EtherCAT®; 32 Outputs; M12 Connector)
DB (Positive Common, NPN; EtherCAT®; 16 Outputs; M12 Connector)
DBN (Negative Common, PNP; EtherCAT®; 16 Outputs; M12 Connector)
FA (Positive Common, NPN; PROFINET; 32 Outputs; M12 Connector)
FAN (Negative Common, PNP; PROFINET; 32 Outputs; M12 Connector)
FB (Positive Common, NPN; PROFINET; 16 Outputs; M12 Connector)
FBN (Negative Common, PNP; PROFINET; 16 Outputs; M12 Connector)
EA (Positive Common, NPN; EtherNet/IP™; 32 Outputs; M12 Connector)
EAN (Negative Common, PNP; EtherNet/IP™; 32 Outputs; M12 Connector)
EB (Positive Common, NPN; EtherNet/IP™; 16 Outputs; M12 Connector)
EBN (Negative Common, PNP; EtherNet/IP™; 16 Outputs; M12 Connector)
GAN (Negative Common, PNP; EtherNet POWERLINK; 32 Outputs; M12 Connector)
GBN (Negative Common, PNP; EtherNet POWERLINK; 16 Outputs; M12 Connector)
KAN (Negative Common, PNP; IO/Link; 32 Outputs; M12 Connector)
Wiring Type
-- Pick an Option --
All Double Wiring
S (All Single Wiring)
Valve Stations
-- Pick an Option --
08 (8 Stations, All Double Wiring)
12 (12 Stations, All Double Wiring)
16 (16 Stations, All Double Wiring)
20 (20 Stations, All Single Wiring)
24 (24 Stations, All Single Wiring)
Port Size
-- Pick an Option --
01 [4(A)/2(B) Port: 1/8; 1(P)/3(EB), 5(EA) Port: 1/4]
C6 [4(A)/2(B) Port: ø6; 1(P)/3(EB), 5(EA) Port: ø10]
C8 [4(A)/2(B) Port: ø8; 1(P)/3(EB), 5(EA) Port: ø10]
N7 [4(A)/2(B) Port: ø1/4"; 1(P)/3(EB), 5(EA) Port: ø3/8"]
Thread Type
-- Pick an Option --
One-touch: None; Thread Piping: Rc
F (G)
N (NPT)
Option
-- Pick an Option --
None
P (Trim Plate)