Proax
CADEN
proax logo
Cart

OT100FT4N2

ABBOfficial Distributor

By ABB

SKU
ABBOT100FT4N2
MPN
1SCA105031R1001
Weight
0.5 kg
This product is Not Cancellable/Not Returnable
4-pole, front operated, door mounted, switch-diconnector / non-fusible diconnect switch with front protected clamp terminals, handle and shaft are not included
Technical Specifications

ABB EcoSolutions

Environmental Information1SCC301264D0201
Environmental Product Declaration - EPD1SCC301280D0201

Dimensions

Product Net Width100 mm
Product Net Height96.5 mm
Product Net Depth / Length66.5 mm
Product Net Weight0.5 kg

Technical

Cable Cross-SectionCu 10 ... 70 mm²
Connecting Capacity Main CircuitFlexible 1x Cu 10…70 mm²
Connecting Capacity Main CircuitStranded 1x Cu 10…70 mm²
Conventional Free-air Thermal Current (Ith)Θ = 40 °C 115 A
Conventional Thermal Current (Ithe)Fully Enclosed 115 A
Degree of ProtectionFront IP20
Distance Between PhasesStandard
Fourth Pole PositionRight Side
Fourth Pole TypeSwitched - Simultaneous Function
Handle TypeHandle and shaft not included
Mechanical Durability20000
Mounting TypeDoor mounting
Number of Poles4P
Operating modeFront
Pollution degree3
Position of Line TerminalsTop In - Bottom Out
Position of Line TerminalsBottom In - Top Out
Power Lossat Rated Operating Conditions per Pole 4.0 W
Rated Conditional Short-Circuit Current (Inc)(125 A fuse, 415 V) 50 kA
Rated Conditional Short-Circuit Current (Inc)(125 A fuse, 690 V) 10 kA
Rated Conditional Short-Circuit Current (Inc)(63 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie)(380 ... 415 V) 100 A
Rated Operational Current AC-21A (Ie)(500 V) 100 A
Rated Operational Current AC-21A (Ie)(690 V) 100 A
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 100 A
Rated Operational Current AC-22A (Ie)(500 V) 100 A
Rated Operational Current AC-22A (Ie)(690 V) 100 A
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 80 A
Rated Operational Current AC-23A (Ie)(500 V) 60 A
Rated Operational Current AC-23A (Ie)(690 V) 40 A
Rated Operational Power AC-23A (Pe)(220 ... 240 V) 22 kW
Rated Operational Power AC-23A (Pe)(400 ... 415 V) 37 kW
Rated Operational Power AC-23A (Pe)(500 V) 37 kW
Rated Operational Power AC-23A (Pe)(690 V) 37 kW
Rated Operational VoltageMain Circuit 750 V
Rated Short-Circuit Making Capacity (Icm)(690 V) 3.6 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 2.5 kA
Recommended Screw DriverMain Circuit Hexagon 4
Special FunctionsNo
StandardsIEC 60947-3 / UL 98 / CSA C22.2 NO.4
Switches Operating MechanismMechanism on Top of the Switch
Terminal TypeScrew Terminals
Tightening torqueacc. IEC 60947-1 6 N·m
Wire Stripping LengthMain Circuit 18-21 mm

Technical UL/CSA

Maximum Operating Voltage UL/CSA600 V
Ampere Rating100 A
Horsepower Rating UL/CSA(110 ... 120 V AC) Single Phase 5 Hp
Horsepower Rating UL/CSA(240 V AC) Single Phase 15 Hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Single Phase 25 Hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Single Phase 20 Hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 30 Hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 50 Hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 50 Hp
Wire Stripping LengthMain Circuit 18-21 mm
Recommended Screw DriverMain Circuit Hexagon 4
Tightening torqueacc. IEC 60947-1 6 N·m
Tightening Torque UL/CSA55 in·lb

Why Proax for ABB OT100FT4N2?

Proax is an authorized distributor of ABB OT100FT4N2 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability