MO165-65

ABBOfficial Distributor

By ABB

SKU
ABBMO16565
MPN
1SAM461000R1017
Weight
1.066 kg
The MO165 manual motor starter magnetic only is a compact and powerful range for motor protection up to 45 kW (400 V) in width of 55 mm. The devices are used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity up to 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starters magnetic only are suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars and power in-feed blocks are available as accessory.
Technical Specifications

Dimensions

Product Net Width55 mm
Product Net Height142.65 mm
Product Net Depth / Length122.1 mm
Product Net Weight0.98 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 30 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(250 V DC) 3 Poles in Series 100 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(400 V AC) 30 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(440 V AC) 30 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(500 V AC) 20 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(690 V AC) 6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(250 V DC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(440 V AC) 45 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(500 V AC) 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(690 V AC) 8 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)975 A
Setting rangeNone
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 30 kW
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 30 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational VoltageMain Circuit 250 V DC
Rated Operational Current (Ie)65 A
Rated Operational Current AC-3 (Ie)65 A
Rated Operational Current AC-3e (Ie)65 A
Rated Operational Current DC-5 (Ie)65 A
Rated Frequency (f)Main Circuit 50 Hz
Rated Frequency (f)Main Circuit 60 Hz
Operating Frequency (fsw)0 ... 415 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Rated Insulation Voltage (Ui)1000 V
Power Loss8.03 W
Number of Poles3
Conventional Free-air Thermal Current (Ith)Main Circuit 65 A
Degree of ProtectionHousing IP20
Degree of ProtectionMain Circuit Terminals IP10
Pollution degree3
Electrical Durability25000 cycle
Mechanical Durability50000 cycle
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 1 ... 35 mm²
Connecting Capacity Main CircuitFlexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Connecting Capacity Main CircuitFlexible 1/2x 1 ... 35 mm²
Connecting Capacity Main CircuitRigid 1/2x 1 ... 4 mm²
Connecting Capacity Main CircuitSolid 1/2x 1 ... 4 mm²
Connecting Capacity Main CircuitStranded 1/2x 1 ... 50 mm²
Tightening torqueMain Circuit 4 N·m
Wire Stripping LengthMain Circuit 16 mm
Recommended Screw DriverPozidriv 2
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 400 V 0 mm
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Minimum Mounting DistanceElectrical Conductive Board, Vertical 75 mm
Minimum Mounting DistanceOther Device Same Type, Horizontal 0 mm
Minimum Mounting DistanceOther Device Same Type, Vertical 150 mm
Actuator TypeRotary Handle
Contact Position IndicationON / OFF / TRIP
StandardsCSA 22.2 No. 14
StandardsIEC/EN 60947-1
StandardsIEC/EN 60947-2
StandardsIEC/EN 60947-4-1
StandardsUL 60947-4-1
RemarksFor overload protection of the motors, an appropriate thermal or electronic overload relays must be used

Technical UL/CSA

Short-circuit current rating (SCCR)Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Short-circuit current rating (SCCR)Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Horsepower Rating UL/CSA(200 V AC) Three Phase 20 Hp
Horsepower Rating UL/CSA(208 V AC) Three Phase 20 Hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 20 Hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 50 Hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 60 Hp
Full Load Amps Motor Use(200 V AC) Three Phase 62.1 A
Full Load Amps Motor Use(208 V AC) Three Phase 59.4 A
Full Load Amps Motor Use(220 ... 240 V AC) Three Phase 54 A
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 65 A
Full Load Amps Motor Use(550 ... 600 V AC) Three Phase 62 A
Locked Rotor Amps(200 V AC) Three Phase 334 A
Locked Rotor Amps(208 V AC) Three Phase 321 A
Locked Rotor Amps(220 ... 240 V AC) Three Phase 290 A
Locked Rotor Amps(440 ... 480 V AC) Three Phase 363 A
Locked Rotor Amps(550 ... 600 V AC) Three Phase 348 A
General Use Rating UL/CSA(600 V AC) 65 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-0 AWG
Connecting Capacity Main Circuit UL/CSAStranded 1/2x 16-0 AWG
Tightening Torque UL/CSAMain Circuit 35 in·lb

Why Proax for ABB MO165-65?

Proax is an authorized distributor of ABB MO165-65 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesMO16565
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability