CADEN
Cart

2800799

Official Distributor

By Phoenix Contact

SKU
PHX2800799
MPN
PT-IQ-5-HF-12DC-UT
Weight
0.123 kg
This product has been discontinued and replaced with 2801293
Series PT-IQ

PT-IQ-5-HF-12DC-UT - Surge protection device

Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for five signal wires. For HF applications and telecommunications interfaces without supply voltage (up to 90 Mbps).

  • Predictive monitoring with 3-stage LED display
  • Integration of the status message into the system controller via group remote signaling
  • Install quickly and error-free with DIN rail connectors
  • Maximum ease of maintenance, thanks to the 2-piece design
  • Maximum protection for MCR applications with high discharge capacity
Technical Specifications

General

NoteRemote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.

Product properties

Product familyPLUGTRAB IQ
IEC test classificationC1
IEC test classificationC2
IEC test classificationC3
IEC test classificationD1
TypeDIN rail module, two-section, divisible
Surge protection fault messageOptical, multi-stage

Insulation characteristics

Overvoltage categoryIII
Pollution degree2

Electrical properties

Nominal voltage UN12 V DC

Connection data

Connection MethodScrew connection
Screw threadM3
Tightening torque0.5 Nm
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section rigid0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 12

Interfaces

Transmission Speed90 Mpbs

Dimensions

Width17.7 mm
Height91 mm
Depth77.5 mm (incl. DIN rail 7.5 mm)
Horizontal pitch1 Div.

Material specifications

Flammability rating according to UL 94V-0
Housing MaterialPA 6.6

Mechanical data

Open side panelNo

Protective circuit

Direction of actionLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Maximum continuous voltage UC15 V DC
Maximum continuous voltage UC10 V AC
Rated current600 mA (40 °C)
Operating effective current IC at UC≤ 100 µA (per path)
Residual current IPE≤ 100 µA (per path)
Nominal discharge current In (8/20) µs (line-line)10 kA
Nominal discharge current In (8/20) µs (line-ground)10 kA
Pulse discharge current Iimp (10/350) µs (line-earth)2.5 kA
Total discharge current Itotal (8/20) µs20 kA
Voltage protection level Up (line-line)≤ 90 V (C1 - 1 kV / 500 A)
Voltage protection level Up (line-line)≤ 145 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-line)≤ 40 V (C3 - 25 A)
Voltage protection level Up (line-line)≤ 40 V (C3 - 50 A)
Voltage protection level Up (line-earth)≤ 90 V (C1 - 1 kV / 500 A)
Voltage protection level Up (line-earth)≤ 145 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-earth)≤ 40 V (C3 - 25 A)
Voltage protection level Up (line-earth)≤ 40 V (C3 - 50 A)
Voltage protection level Up static (line-line)≤ 55 V (C1 - 1 kV / 500 A)
Voltage protection level Up static (line-earth)≤ 55 V (C1 - 1 kV / 500 A)
Response time tA (line-line)≤ 1 ns
Response time tA (line-earth)≤ 1 ns
Input attenuation aE, sym.typ. 0.3 dB (≤ 10 MHz/150 Ω)
Input attenuation aE, asym.typ. 0.3 dB (≤ 10 MHz/150 Ω)
Cut-off frequency fg (3 dB), sym. in 150 Ω systemtyp. 60 MHz
Cut-off frequency fg (3 dB), asym. (signal ground) in 150 Ω systemtyp. 60 MHz
Capacity (core-core)typ. 30 pF
Capacity (line-signalground)typ. 30 pF
Resistance per path1.2 Ω ±5 %
Surge protection fault messageOptical, multi-stage
Max. required back-up fuse600 mA (FF)
Impulse durability (line-line)C1 - 1 kV / 500 A
Impulse durability (line-line)C2 - 10 kV / 5 kA
Impulse durability (line-line)C2 - 10 kA
Impulse durability (line-line)C3 - 50 A
Impulse durability (line-earth)C1 - 1 kV / 500 A
Impulse durability (line-earth)C2 - 10 kV / 5 kA
Impulse durability (line-earth)C2 - 10 kA
Impulse durability (line-earth)C3 - 50 A
Impulse durability (line-earth)D1 - 2.5 kA
Impulse durability (line-signalground)C1 - 1 kV / 500 A
Impulse durability (line-signalground)C2 - 10 kV / 5 kA
Impulse durability (line-signalground)C2 - 10 kA
Impulse durability (line-signalground)C3 - 50 A
Pulse reset time (line-line)≤ 15 ms
Pulse reset time (line-earth)≤ 15 ms

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 4000 m (amsl)
Permissible humidity (operation)5 % ... 95 %

Air clearances and creepage distances

Standards/regulationsIEC 60664-1
Standards/specificationsIEC 61643-21
Note2000 + A1:2008 + A2:2012
Standards/specificationsEN 61643-21
Note2001 + A1:2009 + A2:2013
Standards/specificationsEN 61000-6-2
Note2005
Standards/specificationsEN 61000-6-3
Note2007 + A1:2011

Mounting

Mounting TypeDIN rail: 35 mm
Accessories

Why Proax for Phoenix Contact 2800799?

Proax is an authorized distributor of Phoenix Contact 2800799 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size1
Recommended

Price N/A

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability