2800799
SKU
PHX2800799
MPN
PT-IQ-5-HF-12DC-UT
Weight
0.123 kg
Series PT-IQ
PT-IQ-5-HF-12DC-UT - Surge protection device
Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for five signal wires. For HF applications and telecommunications interfaces without supply voltage (up to 90 Mbps).
- Predictive monitoring with 3-stage LED display
- Integration of the status message into the system controller via group remote signaling
- Install quickly and error-free with DIN rail connectors
- Maximum ease of maintenance, thanks to the 2-piece design
- Maximum protection for MCR applications with high discharge capacity
Technical Specifications
General
| Note | Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector. |
Product properties
| Product family | PLUGTRAB IQ |
| IEC test classification | C1 |
| IEC test classification | C2 |
| IEC test classification | C3 |
| IEC test classification | D1 |
| Type | DIN rail module, two-section, divisible |
| Surge protection fault message | Optical, multi-stage |
Insulation characteristics
| Overvoltage category | III |
| Pollution degree | 2 |
Electrical properties
| Nominal voltage UN | 12 V DC |
Connection data
| Connection Method | Screw connection |
| Screw thread | M3 |
| Tightening torque | 0.5 Nm |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section rigid | 0.2 mm² ... 4 mm² |
| Conductor cross section AWG | 24 ... 12 |
Interfaces
| Transmission Speed | 90 Mpbs |
Dimensions
| Width | 17.7 mm |
| Height | 91 mm |
| Depth | 77.5 mm (incl. DIN rail 7.5 mm) |
| Horizontal pitch | 1 Div. |
Material specifications
| Flammability rating according to UL 94 | V-0 |
| Housing Material | PA 6.6 |
Mechanical data
| Open side panel | No |
Protective circuit
| Direction of action | Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground |
| Maximum continuous voltage UC | 15 V DC |
| Maximum continuous voltage UC | 10 V AC |
| Rated current | 600 mA (40 °C) |
| Operating effective current IC at UC | ≤ 100 µA (per path) |
| Residual current IPE | ≤ 100 µA (per path) |
| Nominal discharge current In (8/20) µs (line-line) | 10 kA |
| Nominal discharge current In (8/20) µs (line-ground) | 10 kA |
| Pulse discharge current Iimp (10/350) µs (line-earth) | 2.5 kA |
| Total discharge current Itotal (8/20) µs | 20 kA |
| Voltage protection level Up (line-line) | ≤ 90 V (C1 - 1 kV / 500 A) |
| Voltage protection level Up (line-line) | ≤ 145 V (C2 - 10 kV / 5 kA) |
| Voltage protection level Up (line-line) | ≤ 40 V (C3 - 25 A) |
| Voltage protection level Up (line-line) | ≤ 40 V (C3 - 50 A) |
| Voltage protection level Up (line-earth) | ≤ 90 V (C1 - 1 kV / 500 A) |
| Voltage protection level Up (line-earth) | ≤ 145 V (C2 - 10 kV / 5 kA) |
| Voltage protection level Up (line-earth) | ≤ 40 V (C3 - 25 A) |
| Voltage protection level Up (line-earth) | ≤ 40 V (C3 - 50 A) |
| Voltage protection level Up static (line-line) | ≤ 55 V (C1 - 1 kV / 500 A) |
| Voltage protection level Up static (line-earth) | ≤ 55 V (C1 - 1 kV / 500 A) |
| Response time tA (line-line) | ≤ 1 ns |
| Response time tA (line-earth) | ≤ 1 ns |
| Input attenuation aE, sym. | typ. 0.3 dB (≤ 10 MHz/150 Ω) |
| Input attenuation aE, asym. | typ. 0.3 dB (≤ 10 MHz/150 Ω) |
| Cut-off frequency fg (3 dB), sym. in 150 Ω system | typ. 60 MHz |
| Cut-off frequency fg (3 dB), asym. (signal ground) in 150 Ω system | typ. 60 MHz |
| Capacity (core-core) | typ. 30 pF |
| Capacity (line-signalground) | typ. 30 pF |
| Resistance per path | 1.2 Ω ±5 % |
| Surge protection fault message | Optical, multi-stage |
| Max. required back-up fuse | 600 mA (FF) |
| Impulse durability (line-line) | C1 - 1 kV / 500 A |
| Impulse durability (line-line) | C2 - 10 kV / 5 kA |
| Impulse durability (line-line) | C2 - 10 kA |
| Impulse durability (line-line) | C3 - 50 A |
| Impulse durability (line-earth) | C1 - 1 kV / 500 A |
| Impulse durability (line-earth) | C2 - 10 kV / 5 kA |
| Impulse durability (line-earth) | C2 - 10 kA |
| Impulse durability (line-earth) | C3 - 50 A |
| Impulse durability (line-earth) | D1 - 2.5 kA |
| Impulse durability (line-signalground) | C1 - 1 kV / 500 A |
| Impulse durability (line-signalground) | C2 - 10 kV / 5 kA |
| Impulse durability (line-signalground) | C2 - 10 kA |
| Impulse durability (line-signalground) | C3 - 50 A |
| Pulse reset time (line-line) | ≤ 15 ms |
| Pulse reset time (line-earth) | ≤ 15 ms |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | ≤ 4000 m (amsl) |
| Permissible humidity (operation) | 5 % ... 95 % |
Air clearances and creepage distances
| Standards/regulations | IEC 60664-1 |
| Standards/specifications | IEC 61643-21 |
| Note | 2000 + A1:2008 + A2:2012 |
| Standards/specifications | EN 61643-21 |
| Note | 2001 + A1:2009 + A2:2013 |
| Standards/specifications | EN 61000-6-2 |
| Note | 2005 |
| Standards/specifications | EN 61000-6-3 |
| Note | 2007 + A1:2011 |
Mounting
| Mounting Type | DIN rail: 35 mm |
Accessories
FK-MC 0,5/ 5-ST-2,5 - PCB connector, nominal cross section: 0.5 mm2, color: green, nominal current: 4 A, rated voltage (III/2): 160 V, contact surface: Tin, contact connection type: Socket, number of potentials: 5, number of rows: 1, number of positions: 5, number of connections: 5, product range: FK-MC 0,5/..-ST, pitch: 2.5 mm, connection method: Push-in spring connection, conductor/PCB connection direction: 0 °, plug-in system: COMBICON FK-MC 0,5, locking: without, mounting: without, type of packaging: packed in cardboard
Why Proax for Phoenix Contact 2800799?
Proax is an authorized distributor of Phoenix Contact 2800799 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |