MPN
2CCS862001R0401
Weight
0.508 kg
The S802S-D40 is a 2-pole High Performance Circuit breaker with D-Dharacteristic, with cage terminal and a rated current of 40 A. It is a current limiting device with a maximum breaking capacity of 50kA at 240/415V. It can be used for voltages up to 400/690V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S802S-D40 complies with IEC/EN 60898-1 and IEC/EN 60947-2 and allows the use for residential, commercial and industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S802S-D40 more comfortable. Due to the fast arc extinction of S802S-D40 your application will be secured.
Technical Specifications

Technical

StandardsIEC/EN 60947-2
StandardsIEC/EN 60898-1
StandardsUL 1077
Tripping characteristicD
Type of Residual CurrentStandard Version
Rated Operational Voltageacc. to IEC 60898-1 400 V AC
Rated Operational Voltageacc. to IEC 60947-2 690 V AC
Operational VoltageMaximum 230/400 V AC
Operational VoltageMinimum 12 V AC
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 690 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Input Voltage TypeAC/DC
Rated Current (In)40 A
Rated Short-Circuit Capacity(400 V AC) 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(415 V AC) 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(440 V AC) 30 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(500 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(690 V AC) 6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(250 V DC) 30 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(415 V AC) 40 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(440 V AC) 22.5 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(500 V AC) 11 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(690 V AC) 4 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(250 V DC) 30 kA
Frequency (f)50 ... 60 Hz
Rated Frequency (f)50/60 Hz
Power Loss8.6 W
Power Lossat Rated Operating Conditions per Pole 4.3 W
Contact Position IndicationON / OFF / TRIP
Energy Limiting Class3
Electrical Endurance6000 cycle
Mechanical Endurance6000 cycle
Number of Protected Poles2
Number of Poles2
Overvoltage categoryIV
Tightening torque3.5 N·m
Tightening torque31 in·lb
Release TypeD
Actuator MarkingI / O
Housing MaterialInsulation group I, RAL 7035
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting PositionAny
Recommended Screw DriverPozidriv 2
Accessories AvailableYes
RemarksConnection from top and bottom Connecting with CU only IP40 in enclosure with cover Cage terminal with captive screw
Connecting CapacityFlexible 0 … 50 mm²
Connecting CapacityRigid 0 … 70 mm²
Terminal TypeScrew Terminals

Technical UL/CSA

Interrupting Rating acc. to UL1077(480Y / 277 V AC) 14 kA
Interrupting Rating acc. to UL1077(600Y / 347 V AC) 6 kA

Dimensions

Width in Number of Modular Spacings3
Product Net Width54 mm
Product Net Height95 mm
Product Net Depth / Length82.5 mm
Product Net Weight490 g
Size2 modules
Built-In Depth (t2)82.5 mm
Dimension Diagram2CCC413003C0201

Installation

Instructions and Manuals2CCC413016M0008

Why Proax for ABB S802S-D40?

Proax is an authorized distributor of ABB S802S-D40 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesS802SD40
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability