Proax

Currency
0 Items
proax logo
Cart
ABBOfficial Distributor

By ABB

SKU
MPN
1SFA898212R7000
Weight
15.569 kg
The softstarter PSTX210-690-70 has a rated maximum operational current of 210 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard.To interact with PSTX, it has a detachable full graphic display with IP66 and 4x outdoor rating. There are four ways to communicate with PSTX. It can be done by hardwire inputs Start/Stop/Reset of fault, and by three programmable digital inputs. Another popular option is the built-in Fieldbus communication Modbus RTU and incl optional ANYBUS modules with every major protocol such as for example Profinet, Profibus, Modbus TCP, Ethernet IP and others. Another way to communicate with PSTX is to use an external adaptor and a Fieldbus plug. PSTX is the complete alternative for any motor starting application. It’s suitable for medium to large-sized three-phase motors with nominal currents from 30...1250 A inline connection or 52...2160 A inside delta connection. Typical applications are, for example, pumps, fans, compressors, and conveyors.
Technical Specifications

Dimensions

Product Net Width258 mm
Product Net Height470 mm
Product Net Depth / Length279 mm
Product Net Weight13.3 kg

Technical

Rated Operational Voltage208 ... 690 V AC
Rated Control Supply Voltage (Us)100 ... 250 V AC
Rated Control Circuit Voltage (Uc)24 V DC
Rated Frequency (f)50/60 Hz
Rated Frequency (f)Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe)(230 V) 59 kW
Rated Operational Power - In-Line Connection (Pe)(400 V) 110 kW
Rated Operational Power - In-Line Connection (Pe)(500 V) 132 kW
Rated Operational Power - In-Line Connection (Pe)(690 V) 184 kW
Rated Operational Current - In-Line Connection (Ie)210 A
Rated Operational Power - Inside Delta Connectionat 230 V 102 kW
Rated Operational Power - Inside Delta Connectionat 400 V 184 kW
Rated Operational Power - Inside Delta Connectionat 500 V 250 kW
Rated Operational Power - Inside Delta Connectionat 690 V 315 kW
Rated Operational Current - Inside Delta Connection360 A
Service Factor Percentage100 %
Overload ProtectionBuilt-in electronic overload protection
Integrated Electronic OverloadYes
Adjustable Rated Motor Current Ie30 ... 100 %
Starting Capacity at Maximum Rated Current Ie4xIe for 10s
Ramp Time1 ... 120 second [unit of time]
Initial Voltage During Start10 ... 99 %
Step Down Voltage Special Ramp100 ... 10 %
Current Limit Function1.5 ... 7.5 xle
Switch for Inside Delta ConnectionYes
Run Signal RelayYes
By-pass Signal RelayYes
Fault Signal RelayYes
Overload Signal RelayYes
Analog Outputs0…10 V, 0…20 mA, 4…20 mA
Signal indication ready to start/standby ON (LED)Green
Signal indication running R (LED)Green
Signal indication protection (LED)Yellow
Signal indication fault (LED)Red
CommunicationModbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of ProtectionIP00
Terminal TypeMain Circuit: Bars
Connecting Capacity Main CircuitHole Diameter 10.2 mm
Connecting Capacity Control CircuitRigid 1 x 2.5 mm²
Connecting Capacity Supply CircuitRigid 1 x 2.5 mm²
Tightening torqueMain Circuit 25 N·m
Product Main TypePSTX210
FunctionAuto phase sequence detection
FunctionAutomatic restart
FunctionCurrent limit
FunctionCurrent limit ramp
FunctionDual current limit
FunctionDynamic brake
FunctionElectricity metering
FunctionElectronic overload Time-to-cool
FunctionEmergency mode
FunctionEvent log
FunctionFull voltage start
FunctionJog with slow speed, forward and reverse
FunctionKeypad password
FunctionKick start
FunctionLimp mode with two-phase motor control if one set of thyristors is shorted
FunctionMotor heating
FunctionPre-start function
FunctionPump cleaning
FunctionReal time clock
FunctionSequence start
FunctionSoft start with torque control
FunctionSoft start with voltage ramp
FunctionSoft stop with torque control
FunctionSoft stop with voltage ramp
FunctionStand still brake
FunctionStart reverse (external contactors)
FunctionThyristor runtime measurement
FunctionTorque limit
FunctionVoltage sags detection
Protection FunctionBypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning DetailsCurrent imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Technical UL/CSA

Maximum Operating Voltage UL/CSAMain Circuit 690 V
Tightening Torque UL/CSAMain Circuit 221.3

Why Proax for ABB PSTX210-690-70?

Proax is an authorized distributor of ABB PSTX210-690-70 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesPSTX21069070
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability