By ABB
SKU
MPN
1SBX209321R1222
Weight
1 kg
AF52R-30-22-12 48-130V50/60HZ-DC Reversing Contactor
Technical Specifications
Dimensions
Product Net Width | 110 mm |
Product Net Depth / Length | 144 mm |
Product Net Height | 151 mm |
Product Net Weight | 2.386 kg |
Technical
Number of Main Contacts NO | 3 |
Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 2 |
Number of Auxiliary Contacts NC | 2 |
Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22 |
Rated Operational Voltage | Auxiliary Circuit 690 V |
Rated Operational Voltage | Main Circuit 690 V |
Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
Rated Frequency (f) | Control Circuit 50 / 60 Hz |
Rated Frequency (f) | Main Circuit 50 / 60 Hz |
Rated Operational Current AC-1 (Ie) | (1000 V) 60 °C 80 A |
Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 100 A |
Rated Operational Current AC-1 (Ie) | (690 V) 70 °C 70 A |
Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 53 A |
Rated Operational Current AC-3 (Ie) | (440 V) 60 °C 53 A |
Rated Operational Current AC-3 (Ie) | (500 V) 60 °C 45 A |
Rated Operational Current AC-3 (Ie) | (690 V) 60 °C 35 A |
Rated Operational Current AC-3 (Ie) | (380 / 400 V) 60 °C 53 A |
Rated Operational Current AC-3 (Ie) | (220 / 230 / 240 V) 60 °C 53 A |
Rated Operational Current AC-3e (Ie) | (415 V) 60 °C 53 A |
Rated Operational Current AC-3e (Ie) | (440 V) 60 °C 53 A |
Rated Operational Current AC-3e (Ie) | (500 V) 60 °C 45 A |
Rated Operational Current AC-3e (Ie) | (690 V) 60 °C 35 A |
Rated Operational Current AC-3e (Ie) | (380 / 400 V) 60 °C 53 A |
Rated Operational Current AC-3e (Ie) | (220 / 230 / 240 V) 60 °C 53 A |
Rated Operational Power AC-3 (Pe) | (415 V) 30 kW |
Rated Operational Power AC-3 (Pe) | (440 V) 30 kW |
Rated Operational Power AC-3 (Pe) | (500 V) 30 kW |
Rated Operational Power AC-3 (Pe) | (690 V) 30 kW |
Rated Operational Power AC-3 (Pe) | (380 / 400 V) 22 kW |
Rated Operational Power AC-3 (Pe) | (220 / 230 / 240 V) 15 kW |
Rated Operational Power AC-3e (Pe) | (415 V) 30 kW |
Rated Operational Power AC-3e (Pe) | (440 V) 30 kW |
Rated Operational Power AC-3e (Pe) | (500 V) 30 kW |
Rated Operational Power AC-3e (Pe) | (690 V) 30 kW |
Rated Operational Power AC-3e (Pe) | (380 / 400 V) 22 kW |
Rated Operational Power AC-3e (Pe) | (220 / 230 / 240 V) 15 kW |
Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
Rated Operational Current AC-15 (Ie) | (690 V) 2 A |
Rated Operational Current AC-15 (Ie) | (24 / 127 V) 6 A |
Rated Operational Current AC-15 (Ie) | (220 / 240 V) 4 A |
Rated Operational Current AC-15 (Ie) | (400 / 440 V) 3 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A |
Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 140 A |
Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A |
Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour |
Maximum Electrical Switching Frequency | (DC-13) 900 cycles per hour |
Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W |
Rated Operational Current DC-13 (Ie) | (48 V) 2.8 A / 134 W |
Rated Operational Current DC-13 (Ie) | (72 V) 1 A / 72 W |
Rated Operational Current DC-13 (Ie) | (110 V) 0.55 A / 60 W |
Rated Operational Current DC-13 (Ie) | (125 V) 0.55 A / 69 W |
Rated Operational Current DC-13 (Ie) | (220 V) 0.27 A / 60 W |
Rated Operational Current DC-13 (Ie) | (250 V) 0.27 A / 68 W |
Rated Operational Current DC-13 (Ie) | (400 V) 0.15 A / 60 W |
Rated Operational Current DC-13 (Ie) | (500 V) 0.13 A / 65 W |
Rated Operational Current DC-13 (Ie) | (600 V) 0.1 A / 60 W |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 690 V |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-5-1 690 V |
Rated Insulation Voltage (Ui) | acc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | 6 kV |
Rated Control Circuit Voltage (Uc) | 50 Hz 48 ... 130 V |
Rated Control Circuit Voltage (Uc) | 60 Hz 48 ... 130 V |
Rated Control Circuit Voltage (Uc) | DC Operation 48 ... 130 V |
Coil Consumption | Average Holding Value 50 / 60 Hz 4 V·A |
Coil Consumption | Average Holding Value 50 Hz 4 V·A |
Coil Consumption | Average Holding Value 60 Hz 4 V·A |
Coil Consumption | Average Holding Value DC 2 W |
Coil Consumption | Average Holding Value, from Warm State 2 W |
Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Mounting by Screws (not supplied) | 2 x M4 or 2 x M6 screws placed diagonally |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 4 ... 35 mm² |
Connecting Capacity Main Circuit | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² |
Connecting Capacity Main Circuit | Rigid Stranded 1/2x 6 ... 35 mm² |
Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² |
Connecting Capacity Control Circuit | Rigid Solid 1/2x 1 ... 2.5 mm² |
Connecting Capacity Control Circuit | Rigid Stranded 1/2x 1 ... 2.5 mm² |
Wire Stripping Length | Auxiliary Circuit 10 mm |
Wire Stripping Length | Control Circuit 10 mm |
Wire Stripping Length | Main Circuit 16 mm |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
Terminal Type | Screw Terminals |
Technical UL/CSA
Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
Connecting Capacity Main Circuit UL/CSA | Rigid Stranded 1/2x 10-2 AWG |
Connecting Capacity Control Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
Connecting Capacity Control Circuit UL/CSA | Rigid Stranded 1/2x 18-14 AWG |
Tightening Torque UL/CSA | Auxiliary Circuit 11 in·lb |
Tightening Torque UL/CSA | Control Circuit 11 in·lb |
Tightening Torque UL/CSA | Main Circuit 35 in·lb |
Why Proax for ABB AF52R-30-22-12?
Proax is an authorized distributor of ABB AF52R-30-22-12 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | AF52R302212 |
Pack Size | 1 |