Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
1227575
Weight
0.07 kg
Series NBC-R

NBC-R4OC/1,0-BC6A/R4OC - Patch cable

Patch cable, degree of protection: IP20, cable length: 1 m, number of positions: 8, 10 Gbps, CAT6A, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet

  • Perfect for office, building, and protected industrial applications (e.g., in control cabinets)
  • Worldwide approval with CE, UL, WEEE, and EAC
  • Secure connection and disconnection with reliable locking clip protection
  • Ideal EMC properties, thanks to 360° shielding
  • Simultaneous power transmission with PoE++
  • Future-proof high-speed data transmission with up to 10 Gbps (CAT6A)
Technical Specifications

Product properties

Sensor TypeEthernet
Number of Positions8
Shieldedyes
Cable outletstraight

Insulation characteristics

Overvoltage categoryI
Degree of pollution2

Electrical properties

Rated voltage (III/2)72 V
Transmission Speed10 Gbps
Power transmissionPoE++

Mechanical data

Insertion force per signal contact30.00 N
Extraction force per signal contact50 N

Material specifications

Flammability rating according to UL 94V0
Contact MaterialBrass
Contact surface materialAu
Contact carrier materialPC
Outer sheath, materialLSZH

Dimensions

Width11.6 mm
Height14.8 mm
Length40 mm

Connection technology

Connection MethodPierce connection

Conductor connection

Connection MethodPierce connection

Connection 1

TypePlug straight RJ45
Shieldedyes
Handle colorgray
Insertion/withdrawal cycles≥ 750
Degree of ProtectionIP20
Ambient Temperature (Operation)-20 °C ... 80 °C

Connection 2

TypePlug straight RJ45
Shieldedyes
Handle colorgray
Insertion/withdrawal cycles≥ 750
Degree of ProtectionIP20
Ambient Temperature (Operation)-20 °C ... 80 °C

Cable/line

Cable Length1.00 m

Ethernet, Type B, 8-pos., CAT6A, LSZH [BC6A]

Shieldedyes
Cable TypeEthernet, Type B, 8-pos., CAT6A, LSZH
Cable type (abbreviation)BC6A
Cable structure4x2xAWG26/7; S/FTP
External Cable Diameter6.50 mm ±0.3 mm
Outer sheath, materialLSZH
External sheath, colorgray
Thickness, outer sheathapprox. 0.70 mm
Conductor materialBare Cu litz wires
Conductor structure signal line7x 0.16 mm
AWG Signal Line26
Material wire insulationPE
Single wire, number of litz wires8
Wire diameter incl. insulation1 mm
Single wire, cross section [AWG]26
ShieldingS/FTP
Optical shield covering70 %
Cable insulation resistance≥ 5000 MΩ*km
Wave impedance100 Ω
Loop resistance≤ 148.00 Ω/km
Minimum bending radius, fixed installation8 x D
Near end crosstalk attenuation (NEXT)75 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)66.3 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)60.3 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)57.2 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)55.8 dB (at 20 МHz)
Near end crosstalk attenuation (NEXT)52.9 dB (at 31.25 МHz)
Near end crosstalk attenuation (NEXT)48.4 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)45.3 dB (at 100 MHz)
Near end crosstalk attenuation (NEXT)40.8 dB (at 200 MHz)
Near end crosstalk attenuation (NEXT)38.1 dB (at 300 MHz)
Near end crosstalk attenuation (NEXT)36.3 dB (at 400 MHz)
Near end crosstalk attenuation (NEXT)34.8 dB (at 500 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)72.3 dB (with 1 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)63.3 dB (at 4 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)58.8 dB (at 8 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)57.3 dB (at 10 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)54.2 dB (at 16 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)52.8 dB (at 20 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)51.3 dB (at 25 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)49.9 dB (at 31.25 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)45.4 dB (at 62.5 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)42.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)37.8 dB (at 200 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)35.1 dB (at 300 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)33.3 dB (at 400 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)31.8 dB (at 500 MHz)
Return attenuation (RL)20 dB (with 1 MHz)
Return attenuation (RL)23 dB (at 4 МHz)
Return attenuation (RL)24.5 dB (at 8 МHz)
Return attenuation (RL)25 dB (at 10 MHz)
Return attenuation (RL)25 dB (at 16 MHz)
Return attenuation (RL)25 dB (at 20 МHz)
Return attenuation (RL)24.2 dB (at 25 MHz)
Return attenuation (RL)23.3 dB (at 31.25 МHz)
Return attenuation (RL)20.7 dB (at 62.5 МHz)
Return attenuation (RL)19 dB (at 100 MHz)
Return attenuation (RL)16.4 dB (at 200 MHz)
Return attenuation (RL)15.6 dB (at 300 MHz)
Return attenuation (RL)15.6 dB (at 400 MHz)
Return attenuation (RL)15.6 dB (at 500 MHz)
Halogen-freecomplying with IEC 60754-1/2
Flame resistanceIEC 60332-1-2/IEC 60332-3-24/CM
Ambient Temperature (Operation)-20 °C ... 80 °C (Cable, flexible installation)
Ambient Temperature (Operation)-20 °C ... 80 °C (cable, fixed installation)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-20 °C ... 80 °C
Ambient temperature (storage/transport)0 °C ... 40 °C

Standards and Regulations

Flame resistanceIEC 60332-1-2

Why Proax for Phoenix Contact NBC-R4OC/1,0-BC6A/R4OC?

Proax is an authorized distributor of Phoenix Contact NBC-R4OC/1,0-BC6A/R4OC and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesNBCR4OC10BC6AR4OC
Pack Size1
Recommended

Available for order

Phoenix Contact Availability