Official Distributor
SKU
MPN
SAC-4P-M12MS SH BK/.../...
Series SAC-4P
SAC-4P-M12MS SH BK/.../... - Sensor/actuator cable
Sensor/actuator cable, 4-position, Plug straight M12, coding: A, on free cable end, cable length: Free input (0.2 ... 40.0 m)
Technical Specifications
Product properties
Application | Standard, U.S. cables |
Number of Positions | 4 |
No. of cable outlets | 1 |
Shielded | yes |
Coding | A |
Insulation characteristics
Overvoltage category | II |
Degree of pollution | 3 |
Material specifications
Flammability rating according to UL 94 | HB |
Material of grip body | TPU, hardly inflammable, self-extinguishing |
Contact Material | CuSn |
Contact surface material | Ni/Au |
Contact carrier material | TPU GF |
Material for screw connection | Zinc die-cast, nickel-plated |
Electrical properties
Insulation resistance | ≥ 100 MΩ |
Nominal voltage UN | 48 V AC |
Nominal voltage UN | 60 V DC |
Nominal current IN | 4 A |
Mechanical data
Insertion/withdrawal cycles | ≥ 100 |
Signaling
Status display | No |
Status display present | No |
Conductor connection
Tightening torque | 0.4 Nm (M12 connector) |
Connection 1
Type | Plug straight M12 |
Coding type | A |
Connection 2
Type | free cable end |
Cable/line
Cable Length | Free input (0.2 ... 40.0 m) |
PUR halogen-free black [PUR]
Cable weight | 36 kg/km |
UL AWM style | 20549 / 10493 (80°C/300 V) |
Number of Positions | 4 |
Shielded | yes |
Cable Type | PUR halogen-free black [PUR] |
Cable Type | PUR halogen-free black PUR |
Conductor structure signal line | 42x 0.10 mm |
AWG Signal Line | 22 |
Conductor Cross Section | 4x 0.34 mm² (Signal line) |
Wire diameter incl. insulation | 1.27 mm ±0.02 mm (Signal line) |
External Cable Diameter | 4.95 mm ±0.2 mm |
Outer sheath, material | PUR |
External sheath, color | black-gray RAL 7021 |
Conductor material | Bare Cu litz wires |
Material wire insulation | PP |
Single wire, color | brown, white, blue, black |
Thickness, insulation | ≥ 0.21 mm |
Thickness, outer sheath | approx. 0.50 mm |
Overall twist | 4 wires, twisted |
Shielding | Tinned copper braided shield |
Optical shield covering | 80 % |
Max. conductor resistance | max. 58 Ω/km (at 20 °C) |
Insulation resistance | ≥ 100 GΩ*km (at 20 °C) |
Wave impedance | ≥ 62 Ω (f = 10 MHz) |
Cable capacity | ≤ 80 pF/m (Conductor-Conductor) |
Cable capacity | ≤ 135 pF/m (Wire/shield) |
Nominal voltage, cable | ≤ 300 V |
Test voltage | ≥ 3000 V |
Minimum bending radius, fixed installation | 5 x D |
Minimum bending radius, flexible installation | 10 x D |
Smallest bending radius, fixed installation | 25 mm |
Smallest bending radius, movable installation | 50 mm |
Max. bending cycles | 10000000 |
Halogen-free | in accordance with DIN VDE 0472 part 815 |
Halogen-free | in accordance with DIN EN 50267-2-1 |
Flame resistance | in accordance with UL 758/1581 FT2 |
Flame resistance | DIN EN 60332-2-2 (20 s) |
Resistance to Oil | in accordance with DIN EN 60811-2-1 |
Other resistance | Highly resistant to acids, alkaline solutions and solvents |
Other resistance | hydrolysis and microbe resistant |
Other resistance | Resistant to salt water |
Other resistance | partly UV-resistant (in accordance with DIN EN ISO 4892-2-A) |
Other resistance | abrasion-resistant |
Special Properties | Flexible cable conduit capable |
Special Properties | Silicone-free |
Special Properties | Free of substances which would hinder coating with paint or varnish |
Special Properties | Low adhesion surface |
Ambient Temperature (Operation) | -40 °C ... 80 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -25 °C ... 80 °C (Cable, flexible installation) |
PUR halogen-free yellow [240]
Cable weight | 46 kg/km |
UL AWM style | 20549 |
Number of Positions | 4 |
Shielded | yes |
Cable Type | PUR halogen-free yellow [240] |
Cable Type | PUR halogen-free yellow 240 |
Conductor structure signal line | 42x 0.10 mm |
AWG Signal Line | 22 |
Conductor Cross Section | 4x 0.34 mm² |
Wire diameter incl. insulation | 1.27 mm ±0.02 mm |
External Cable Diameter | 5.90 mm ±0.2 mm |
Outer sheath, material | PUR |
External sheath, color | yellow |
Conductor material | Bare Cu litz wires |
Material wire insulation | PP |
Single wire, color | brown, white, blue, black |
Thickness, insulation | ≥ 0.21 mm |
Thickness, outer sheath | approx. 1.00 mm |
Overall twist | 4 wires, twisted |
Length of twist, overall twist | 50 mm |
Shielding | Braided copper wires |
Optical shield covering | 85 % |
Max. conductor resistance | 58 Ω/km (at 20 °C) |
Insulation resistance | ≥ 1 GΩ*km (at 20 °C) |
Nominal voltage, cable | ≤ 300 V AC |
Test voltage | ≥ 3000 V AC (Spark test) |
Test voltage Core/Shield | ≥ 2000.00 V AC (for 60 s) |
Minimum bending radius, fixed installation | 5 x D |
Minimum bending radius, flexible installation | 10 x D |
Smallest bending radius, fixed installation | 30 mm |
Smallest bending radius, movable installation | 59 mm |
Max. bending cycles | 2000000 |
Halogen-free | in accordance with DIN VDE 0472 part 815 |
Halogen-free | in accordance with EN 50267-2-1 |
Flame resistance | in accordance with UL 758/1581 FT2 |
Resistance to Oil | According to DIN EN 60811-2-1, 168 h at 100°C |
Resistance to Oil | According to UL 758, 168 h at 60°C |
Other resistance | hydrolysis and microbe resistant |
Other resistance | Resistant to salt water |
Other resistance | abrasion-resistant |
Other resistance | Low adhesion |
Ambient Temperature (Operation) | -40 °C ... 80 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -25 °C ... 80 °C (Cable, flexible installation) |
Black PVC 105°C [535]
Cable weight | 48 kg/km |
UL AWM style | 2517 (105 °C / 300 V) |
Number of Positions | 4 |
Shielded | yes |
Cable Type | Black PVC 105°C [535] |
Cable Type | Black PVC 105°C 535 |
Conductor structure signal line | 30x 1.30 mm |
AWG Signal Line | 22 |
Wire diameter incl. insulation | 1.27 mm ±0.03 mm |
External Cable Diameter | 5.50 mm ±0.2 mm |
Outer sheath, material | PVC |
External sheath, color | black |
Conductor material | Tin-plated Cu litz wires |
Material wire insulation | PVC |
Single wire, color | brown, blue, black, white |
Overall twist | 4 wires, twisted |
Shielding | Tinned copper braided shield |
Optical shield covering | 85 % |
Nominal voltage, cable | 300 V |
Minimum bending radius, flexible installation | 12 x D |
Smallest bending radius, movable installation | 66 mm |
Flame resistance | FT4 |
Other resistance | UV resistant |
Special Properties | UL standards PLTC and ITC |
Ambient Temperature (Operation) | -30 °C ... 105 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -5 °C ... 105 °C (Cable, flexible installation) |
PVC yellow 105 °C [542]
Cable weight | 48 kg/km |
UL AWM style | 2517 (105 °C / 300 V) |
Number of Positions | 4 |
Shielded | yes |
Cable Type | PVC yellow 105 °C [542] |
Cable Type | PVC yellow 105 °C 542 |
Conductor structure signal line | 30x 1.30 mm |
AWG Signal Line | 22 |
Wire diameter incl. insulation | 1.27 mm ±0.03 mm |
External Cable Diameter | 5.50 mm ±0.2 mm |
Outer sheath, material | PVC |
External sheath, color | yellow |
Conductor material | Tin-plated Cu litz wires |
Material wire insulation | PVC |
Single wire, color | brown, blue, black, white |
Overall twist | 4 wires, twisted |
Shielding | Tinned copper braided shield |
Optical shield covering | 85 % |
Max. conductor resistance | max. 50.5 Ω/km (20 °C) |
Insulation resistance | ≥ (550 M Ohms/m @ 500V) |
Nominal voltage, cable | 300 V |
Minimum bending radius, flexible installation | 12 x D |
Smallest bending radius, movable installation | 66 mm |
Flame resistance | FT4 |
Other resistance | UV resistant |
Special Properties | UL standards PLTC and ITC |
Ambient Temperature (Operation) | -30 °C ... 105 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -5 °C ... 105 °C (Cable, flexible installation) |
PVC gray 105 °C [544]
Cable weight | 40 kg/km |
UL AWM style | 2517 (105 °C / 300 V) |
Number of Positions | 4 |
Shielded | yes |
Cable Type | PVC gray 105 °C [544] |
Cable Type | PVC gray 105 °C 544 |
Conductor structure signal line | 30x 1.30 mm |
AWG Signal Line | 22 |
Wire diameter incl. insulation | 1.27 mm ±0.03 mm |
External Cable Diameter | 5.50 mm ±0.2 mm |
Outer sheath, material | PVC |
External sheath, color | gray |
Conductor material | Tin-plated Cu litz wires |
Material wire insulation | PVC |
Single wire, color | brown, white, blue, black |
Overall twist | 4 wires, twisted |
Shielding | Tinned copper braided shield |
Optical shield covering | 85 % |
Max. conductor resistance | max. 50.5 Ω/km (20 °C) |
Insulation resistance | ≥ (550 M Ohms/m @ 500V) |
Nominal voltage, cable | 300 V |
Minimum bending radius, flexible installation | 12 x D |
Smallest bending radius, movable installation | 66 mm |
Flame resistance | FT4 |
Other resistance | UV resistant |
Special Properties | UL standards PLTC and ITC |
Ambient Temperature (Operation) | -30 °C ... 105 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -5 °C ... 105 °C (Cable, flexible installation) |
Ambient conditions
Degree of Protection | IP65 |
Degree of Protection | IP67 |
Ambient Temperature (Operation) | -25 °C ... 90 °C (Plug / socket) |
M12
Standard designation | M12 connector |
Standards/specifications | IEC 61076-2-101 |
Why Proax for Phoenix Contact 1405896?
Proax is an authorized distributor of Phoenix Contact 1405896 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended