SKU
MPN
NBC-MSD/25,2-939/MSD SCO SI
Weight
0.022 kg
Series NBC-MSD
NBC-MSD/25,2-939/MSD SCO SI - Network cable
Network cable, PROFINET CAT5 (100 Mbps), 4-position, PE-X halogen-free, black, shielded (Aluminum-lined polyester foil, tinned copper braided shield), Plug straight M12 SPEEDCON / IP65, on Plug straight M12 SPEEDCON / IP65, cable length: 25.2 m, Product tested according to customer specification/rail application
Technical Specifications
Notes
General | The cable is 100% electrically tested for continuity. |
Product properties
Sensor Type | PROFINET |
Number of Positions | 4 |
No. of cable outlets | 1 |
Shielded | yes |
Coding | D |
Insulation characteristics
Overvoltage category | II |
Degree of pollution | 3 |
Interfaces
Bus system | PROFINET |
Signal type/category | PROFINET CAT5 (IEC 11801), 100 Mbps |
Signaling
Status display | No |
Status display present | No |
Electrical properties
Nominal voltage UN | 48 V AC |
Nominal voltage UN | 60 V DC |
Nominal current IN | 4 A |
Transmission medium | Copper |
Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
Material specifications
Flammability rating according to UL 94 | V0 |
Connection 1
Type | Plug straight M12 SPEEDCON / IP65 |
Number of Positions | 4 |
Locking Type | SPEEDCON |
Shielded | yes |
Handle color | black |
Material | CuSn (Contact) |
Material | Ni/Au (Contact surface) |
Material | PA (Contact carriers) |
Material | TPU, hardly inflammable, self-extinguishing (Grip) |
Material | Zinc die-cast, nickel-plated (Screw connection) |
Degree of Protection | IP65 |
Connection 2
Type | Plug straight M12 SPEEDCON / IP65 |
Locking Type | SPEEDCON |
Degree of Protection | IP65 |
Cable/line
Cable Length | 25.2 m |
PROFINET BETAtrans® railway application CAT5 [939]
Cable weight | 71 kg/km |
Number of Positions | 4 |
Shielded | yes |
Cable Type | PROFINET BETAtrans® railway application CAT5 [939] |
Conductor structure | 1x4xAWG22/7, SF/TQ |
Signal runtime | 4.4 ns/m |
Signal speed | 0.75 c |
Conductor structure signal line | 7x 0.25 mm |
AWG Signal Line | 22 |
Conductor Cross Section | 4x 0.34 mm² |
Wire diameter incl. insulation | 1.4 mm ±0.1 mm |
External Cable Diameter | 6.60 mm ±0.2 mm |
Outer sheath, material | PE-X |
External sheath, color | black |
Conductor material | Tin-plated Cu litz wires |
Material wire insulation | Cell PE |
Single wire, color | white-blue, orange-yellow |
Thickness, outer sheath | 1.00 mm |
Overall twist | Star quad |
Max. conductor resistance | ≤ 54.4 Ω/km |
Insulation resistance | ≥ 5 GΩ*km |
Coupling resistance | < 13.00 mΩ/m (f = 1 MHz) |
Coupling resistance | < 8.00 mΩ/m (f = 10 MHz ... 100 MHz) |
Wave impedance | 100 Ω ±5 Ω (f = 100 MHz) |
Cable capacity | 44 nF/km (Line-line) |
Cable impedance | 100 Ω ±15 Ω (f = 0.5 MHz ... 3 MHz) |
Nominal voltage, cable | 125 V |
Test voltage Core/Core | 1000 V AC (50 Hz, 1 min.) |
Test voltage Core/Shield | 1000.00 V AC (50 Hz, 1 min.) |
Minimum bending radius, fixed installation | 5 x D |
Minimum bending radius, flexible installation | 6 x D |
Smallest bending radius, fixed installation | 33 mm |
Smallest bending radius, movable installation | 40 mm |
Tensile strength | ≤ 60 N (temporary) |
Tensile strength | ≤ 15 N (Permanent) |
Near end crosstalk attenuation (NEXT) | 76 dB (with 1 MHz) |
Near end crosstalk attenuation (NEXT) | 71 dB (at 4 МHz) |
Near end crosstalk attenuation (NEXT) | 64 dB (at 10 MHz) |
Near end crosstalk attenuation (NEXT) | 60 dB (at 16 MHz) |
Near end crosstalk attenuation (NEXT) | 56 dB (at 31.25 МHz) |
Near end crosstalk attenuation (NEXT) | 52 dB (at 62.5 МHz) |
Near end crosstalk attenuation (NEXT) | 48 dB (at 100 MHz) |
Near end crosstalk attenuation (NEXT) | 45 dB (at 155 MHz) |
Near end crosstalk attenuation (NEXT) | 42 dB (at 200 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 73 dB (with 1 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 68 dB (at 4 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 61 dB (at 10 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 57 dB (at 16 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 53 dB (at 31.25 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 49 dB (at 62.5 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 45 dB (at 100 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 42 dB (at 155 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 39 dB (at 200 MHz) |
Return attenuation (RL) | 25 dB (with 1 MHz) |
Return attenuation (RL) | 25 dB (at 4 МHz) |
Return attenuation (RL) | 28 dB (at 10 MHz) |
Return attenuation (RL) | 28 dB (at 16 MHz) |
Return attenuation (RL) | 27 dB (at 31.25 МHz) |
Return attenuation (RL) | 26 dB (at 62.5 МHz) |
Return attenuation (RL) | 25 dB (at 100 MHz) |
Return attenuation (RL) | 25 dB (at 155 MHz) |
Return attenuation (RL) | 23 dB (at 200 MHz) |
Shield attenuation | 1.5 dB (with 1 MHz) |
Shield attenuation | 3.3 dB (at 4 МHz) |
Shield attenuation | 5.3 dB (at 10 MHz) |
Shield attenuation | 6.9 dB (at 16 MHz) |
Shield attenuation | 9.9 dB (at 31.25 МHz) |
Shield attenuation | 14.5 dB (at 62.5 МHz) |
Shield attenuation | 18.8 dB (at 100 MHz) |
Shield attenuation | 23.6 dB (at 155 MHz) |
Shield attenuation | 27.3 dB (at 200 MHz) |
Shield attenuation | 60.00 dB (up to 1000 MHz) |
Halogen-free | in accordance with EN 50267-2-1 |
Halogen-free | in accordance with EN 60684-2 |
Flame resistance | in accordance with EN 60332-1-2 |
Flame resistance | in accordance with EN 50266-2-5 |
Flame resistance | in accordance with ISO 14572 5.21 (UN ECE-R 118.01) |
Concentration of fumes | EN 61034-2 |
Resistance to Oil | in accordance with EN 50306-4, 72 hours at 100°C, IRM 902 |
Fire protection in rail vehicles | BS 6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II) |
Fire protection in rail vehicles | DIN 5510-2 (Fire protection level 1, 2, 3, 4) |
Fire protection in rail vehicles | EN 45545-2 (Risk level HL1 - HL3) |
Fire protection in rail vehicles | EN 50306-4 |
Fire protection in rail vehicles | NF F16-101 (Classification C/F1) |
Fire protection in rail vehicles | NF F16-101 (Internal cable A1, A2, B/external cable A1, A2, B) |
Fire protection in rail vehicles | NFPA 130 |
Fire protection in rail vehicles | PN-K-02511 |
Fire protection in rail vehicles | UIC 564-2 (Class A) |
Other resistance | Resistant to fuel (in accordance with EN 50306-4, 168 hours at 70°C, IRM 903) |
Other resistance | Resistant to ozone (in accordance with EN 50306-4, 72 hours at 40°C, method B, volumetric concentration of 200 x 10-6) |
Ambient Temperature (Operation) | -40 °C ... 85 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -25 °C ... 70 °C (Cable, flexible installation) |
Ambient Temperature (Operation) | 160 °C (Short circuit) |
Standards and Regulations
Standard designation | M12 connector |
Standards/specifications | IEC 61076-2-101 |
Why Proax for Phoenix Contact 1425179?
Proax is an authorized distributor of Phoenix Contact 1425179 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- NBC-MSD/10,0-937 SCO RAIL - Network cable, PROFINET CAT5 (100 Mbps), Ethernet CAT5 (100 Mbps), 4-position, PE-X halogen-free, black RAL 9005, shielded (Plastic-coated aluminum foil, tinned copper braided shield), Plug straight M12 SPEEDCON, coding: D / IP65, on free cable end, cable length: 10 m, For railway applications
- NBC-MSD/1,0-937/MSD RX-TX - Network cable, PROFINET CAT5, PROFINET CAT5e, 4-pos., RADOX® GKW S, RAL 9005 (black), shielded, straight M12-SPEEDCON plug/IP65, coding: D to straight M12-SPEEDCON plug/IP65, coding D, cable length: 1 m, product checked according to customer specification/railway application
- NBC-MSD/65,0-93B/MSD SCO - Network cable, PROFINET CAT5 (100 Mbps), EtherCAT® CAT5 (100 Mbps), 4-position, PVC/PVC, green RAL 6018, shielded (Aluminum-coated foil, tinned copper braided shield), Plug straight M12 SPEEDCON, coding: D / IP67, on Plug straight M12 SPEEDCON, coding: D / IP67, cable length: 65 m