Official Distributor
SKU
MPN
VS-M12MSD-M12FSD-936-LI/1,5
Weight
0.153 kg
Series VS-M
VS-M12MSD-M12FSD-936-LI/1,5 - Network cable
Assembled PROFINET cable, CAT5e, shielded, star quad, AWG 22 (7-wire), black, M12 plug to M12 socket, length 1.5 m
Technical Specifications
Product properties
Number of Positions | 4 |
Shielded | yes |
Insulation characteristics
Overvoltage category | II |
Degree of pollution | 3 |
Electrical properties
Nominal voltage UN | 48 V AC |
Nominal voltage UN | 60 V DC |
Nominal current IN | 4 A |
Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
Material specifications
Flammability rating according to UL 94 | V0 |
Cable/line
Cable Length | 1.5 m |
PROFINET RADOX® railway application CAT5 reinforced [936]
Cable weight | 81 g/m |
Number of Positions | 4 |
Shielded | yes |
Cable Type | PROFINET RADOX® railway application CAT5 reinforced [936] |
Conductor structure | 1x4xAWG22/7, SF/TQ |
Signal speed | 66 c |
Conductor structure signal line | 7x 0.25 mm |
AWG Signal Line | 22 |
Conductor Cross Section | 4x 0.34 mm² |
Wire diameter incl. insulation | 1.95 mm |
External Cable Diameter | 7.25 mm ±0.3 mm |
Outer sheath, material | PE-X |
External sheath, color | black RAL 9005 |
Conductor material | silver-plated Cu litz wires |
Material wire insulation | PE-X |
Single wire, color | white-blue, orange-yellow |
Thickness, outer sheath | ≥ 0.80 mm |
Overall twist | Star quad |
Optical shield covering | 100 % |
Max. conductor resistance | ≤ 54.4 Ω/km |
Coupling resistance | 200.00 mΩ/m (f ≤ 30 MHz) |
Wave impedance | 100 Ω ±5 Ω (f = 100 MHz) |
Working capacitance | ≤ 65 pF (Line-line) |
Working capacitance | ≤ 100 pF (Line-shield) |
Nominal voltage, cable | 300 V AC |
Test voltage | 2000 V AC (50 Hz, 5 minutes) |
Minimum bending radius, fixed installation | 6 x D |
Minimum bending radius, flexible installation | 10 x D |
Smallest bending radius, fixed installation | 44 mm |
Smallest bending radius, movable installation | 73 mm |
Near end crosstalk attenuation (NEXT) | 80 dB (with 1 MHz) |
Near end crosstalk attenuation (NEXT) | 76 dB (at 4 МHz) |
Near end crosstalk attenuation (NEXT) | 67 dB (at 10 MHz) |
Near end crosstalk attenuation (NEXT) | 60 dB (at 31.5 МHz) |
Near end crosstalk attenuation (NEXT) | 56 dB (at 62.5 МHz) |
Near end crosstalk attenuation (NEXT) | 53 dB (at 100 MHz) |
Return attenuation (RL) | 35 dB (at 4 МHz) |
Return attenuation (RL) | 35 dB (at 10 MHz) |
Return attenuation (RL) | 35 dB (at 31.5 МHz) |
Return attenuation (RL) | 33 dB (at 62.5 МHz) |
Return attenuation (RL) | 33 dB (at 100 MHz) |
Remote crosstalk attenuation (FEXT) | 80 dB (with 1 MHz) |
Remote crosstalk attenuation (FEXT) | 70 dB (at 4 МHz) |
Remote crosstalk attenuation (FEXT) | 65 dB (at 10 MHz) |
Remote crosstalk attenuation (FEXT) | 58 dB (at 31.5 МHz) |
Remote crosstalk attenuation (FEXT) | 59 dB (at 62.5 МHz) |
Remote crosstalk attenuation (FEXT) | 67 dB (at 100 MHz) |
Shield attenuation | 2 dB (with 1 MHz) |
Shield attenuation | 4 dB (at 4 МHz) |
Shield attenuation | 6.5 dB (at 10 MHz) |
Shield attenuation | 10.5 dB (at 31.5 МHz) |
Shield attenuation | 14 dB (at 62.5 МHz) |
Shield attenuation | 18 dB (at 100 MHz) |
Shield attenuation | 40.00 dB (30 MHz ≤ f ≤ 100 MHz) |
Halogen-free | in accordance with EN 50267-2-1 |
Flame resistance | EN 60332-1-2 |
Flame resistance | EN 50266 |
Flame resistance | EN 60332-3-25 |
Flame resistance | NF C32-070, 2.1 |
Flame resistance | NF C32-070, 2.2 |
Flame resistance | UL 1685, 12 (FT4) |
Flame resistance | in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01) |
Fume corrosiveness | EN 50267-2-2 |
Fume toxicity | BS 6853 B.1 |
Fume toxicity | EN 50305, 9.2 |
Concentration of fumes | BS 6853 D.8.7 |
Concentration of fumes | EN 61034-2 |
Concentration of fumes | UL 1685, 12 (FT4) |
Resistance to Oil | according to IRM 902, 72 h at 100 °C |
Fire protection in rail vehicles | BS 6853 (Category Ia, Ib, II) |
Fire protection in rail vehicles | GM/RT 2130 (Category Ia, Ib, II) |
Fire protection in rail vehicles | EN 45545 (Risk level HL1 - HL3) |
Fire protection in rail vehicles | DIN 5510 (Fire protection level 1, 2, 3, 4) |
Fire protection in rail vehicles | NF F16-101 (Category A1, A2, B) |
Fire protection in rail vehicles | NF F16-101 (Class C/F0) |
Fire protection in rail vehicles | NFPA 130 |
Fire protection in rail vehicles | UNI CEI 11170 (Risk level LR1 - LR4) |
Other resistance | Resistance to fuels (according to IRM 903, 168 h at 70 °C) |
Ambient Temperature (Operation) | -50 °C ... 90 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -40 °C ... 90 °C (Cable, flexible installation) |
Why Proax for Phoenix Contact 1403370?
Proax is an authorized distributor of Phoenix Contact 1403370 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- 1454244 - Network cable, PROFINET CAT5 (100 Mbps), Ethernet CAT5 (100 Mbps), 4-position, PE-X halogen-free, black RAL 9005, shielded (Plastic-coated aluminum foil, tinned copper braided shield), Plug straight M12, coding: D / IP69K, on Plug straight M12, coding: D / IP69K, cable length: 5 m, for outdoor applications, with high-grade steel knurl
- 1454231 - Network cable, Ethernet CAT5 (100 Mbps), PROFINET CAT5 (100 Mbps), 4-position, PE-X halogen-free, black RAL 9005, shielded (Plastic-coated aluminum foil, tinned copper braided shield), Plug straight M12, coding: D / IP69K, on Plug straight M12, coding: D / IP69K, cable length: 2 m, for outdoor applications, with high-grade steel knurl