1078433
SKU
PHX1078433
MPN
BLT-T2-1S-305-UT
Weight
0.042 kg
Series BLT-T2
BLT-T2-1S-305-UT - Type 2 surge arrester
Type 2 surge arrester for universal mounting in lights, cable connection boxes, installation boxes, sill-type trunking, underfloor installations or direct installation in the end device. Specifically for insulation class I with optical fault indication. Installation in branch or through wiring. Version: 230 V AC
- Optimal additional protection of the building installation for longer service life and increased availability of the end devices
- Optimal protection of the power supply for longer service life and increased availability of the LED lighting
- Excellent level of information provided, thanks to shutdown function for the load circuit in the event of an error
- Simple condition monitoring without voltage on the device with a mechanical/visual status indicator
- Flexible installation, thanks to mounting via integrated elongated holes
- Stub or through-wiring connection
- Flexible installation
- Fixed via integrated elongated holes
- Compact design
- Optical, mechanical status indicator
- Compact design
- Universal use for street, tunnel or object lighting
- L' signalizes the failure of the surge protective device due to disconnection of the power supply to the lights
Technical Specifications
Product properties
| IEC test classification | II / III |
| EN type | T2 / T3 |
| IEC power supply system | TN-S |
| IEC power supply system | TT |
| Distance between live and grounded parts | 3 mm |
| Installation location of the disconnect device | Internal |
| Accessibility | Accessible |
| SPD failure behavior | OCM |
| Surge protection fault message | optical |
Insulation characteristics
| Protection class | I |
| Overvoltage category | III |
| Pollution degree | 2 |
Electrical properties
| Nominal frequency fN | 50 Hz (60 Hz) |
| Nominal voltage UN | 100 V AC ... 230 V AC (TN-S) |
| Nominal voltage UN | 100 V AC ... 230 V AC (TT) |
| Dielectric strength | < 2.2 kV (1 min) |
Connection data
| Connection Method | Screw terminal blocks |
| Screw thread | M3 |
| Tightening torque | 0.6 Nm |
| Stripping length | 8 mm |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section rigid | 0.2 mm² ... 4 mm² |
Dimensions
| Width | 36.5 mm |
| Height | 56 mm |
| Depth | 34 mm |
Material specifications
| Color | light grey (RAL 7035) |
| Flammability rating according to UL 94 | V-0 |
| CTI value of material | 600 |
| Insulating material | PA 6.6 |
| Material group | I |
| Housing Material | PA 6.6 |
Protective circuit
| Mode of protection | L-N |
| Mode of protection | L-PE |
| Mode of protection | N-PE |
| Nominal voltage UN | 100 V AC ... 230 V AC (TN-S) |
| Nominal voltage UN | 100 V AC ... 230 V AC (TT) |
| Nominal frequency fN | 50 Hz (60 Hz) |
| Maximum continuous operating voltage UC (L-N) | 305 V AC |
| Maximum continuous operating voltage UC (L-PE) | 265 V AC |
| Maximum continuous operating voltage UC (N-PE) | 265 V AC |
| Rated load current IL | 16 A |
| Residual current IPE | ≤ 5 µA |
| Nominal discharge current In (8/20) µs (L-N) | 5 kA |
| Nominal discharge current In (8/20) µs (L-PE) | 5 kA |
| Nominal discharge current In (8/20) µs (N-PE) | 10 kA |
| Maximum discharge current Imax (8/20) µs (L-N) | 10 kA |
| Maximum discharge current Imax (8/20) µs (L-PE) | 10 kA |
| Maximum discharge current Imax (8/20) µs (N-PE) | 20 kA |
| Combination wave UOC (L-N) | 10 kV |
| Combination wave UOC (L-PE) | 10 kV |
| Combination wave UOC (N-PE) | 20 kV |
| Total discharge current Itotal (8/20) µs | 20 kA |
| Follow current interrupt rating Ifi (N-PE) | 100 A () |
| Short-circuit current rating ISCCR | 10 kA (6 A gG backup fuse) |
| Short-circuit current rating ISCCR | 3 kA (16 A MCB B/C backup fuse) |
| Voltage protection level Up (L-N) | ≤ 1.3 kV |
| Voltage protection level Up (L-PE) | ≤ 1.5 kV |
| Voltage protection level Up (N-PE) | ≤ 1.5 kV |
| TOV behavior at UT (L-N) | 336 V AC (5 s / withstand mode) |
| TOV behavior at UT (L-N) | 440 V AC (120 min / safe failure mode) |
| TOV behavior at UT (L-PE) | 440 V AC (5 s / withstand mode) |
| TOV behavior at UT (L-PE) | 440 V AC (120 min / safe failure mode) |
| TOV behavior at UT (N-PE) | 1200 V AC (200 ms / safe failure mode) |
| Response time tA (L-N) | ≤ 25 ns |
| Response time tA (L-PE) | ≤ 100 ns |
| Response time tA (N-PE) | ≤ 100 ns |
| Max. backup fuse with V-type through wiring | 16 A (MCB B/C) |
| Max. backup fuse with branch wiring | 16 A (MCB B/C) |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -40 °C ... 80 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m (amsl) |
| Permissible humidity (operation) | 5 % ... 95 % |
| Shock (operation) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Vibration (Operation) | 5g (5 ... 500 Hz / 2.5 h / X, Y, Z) |
Standards and Regulations
| Standards/specifications | IEC 61643-11 |
| Note | 2011 |
EN 61643-11
| Standards/specifications | EN 61643-11 |
| Note | 2012 |
Mounting
| Mounting Type | 4 mm screw |
| Mounting Position | Internal |
Why Proax for Phoenix Contact 1078433?
Proax is an authorized distributor of Phoenix Contact 1078433 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 10 |