Official Distributor
SKU
MPN
SAC-4P-M12MS/2,0-28R/M12FR SH
Weight
0.138 kg
Series SAC-4P
SAC-4P-M12MS/2,0-28R/M12FR SH - Sensor/actuator cable
Sensor/actuator cable, 4-position, PE-X halogen-free, black RAL 9005, shielded (Tinned copper braided shield), Plug straight M12, coding: A, on Socket angled M12, coding: A, cable length: 2 m
Technical Specifications
Product properties
Number of Positions | 4 |
Shielded | yes |
Electrical properties
Nominal voltage UN | 48 V AC |
Nominal voltage UN | 60 V DC |
Connection 1
Type | Plug straight M12 |
Number of Positions | 4 |
Coding type | A |
Connection 2
Type | Socket angled M12 |
Number of Positions | 4 |
Coding type | A |
Cable/line
Cable Length | 2 m |
Shielded black RADOX® [28R]
Cable weight | 56 kg/km |
Number of Positions | 4 |
Shielded | yes |
Cable Type | Shielded black RADOX® [28R] |
Conductor structure signal line | 19x 0.18 mm |
AWG Signal Line | 20 |
Conductor Cross Section | 4x 0.5 mm² |
Wire diameter incl. insulation | 1.43 mm |
External Cable Diameter | 5.40 mm ±0.3 mm |
Outer sheath, material | PE-X |
External sheath, color | black RAL 9005 |
Conductor material | Tin-plated Cu litz wires |
Material wire insulation | PE-X |
Single wire, color | white 1, white 2, white 3, white 4 |
Overall twist | 4 wires, twisted |
Optical shield covering | 85 % |
Max. conductor resistance | ≤ 40.1 Ω/km |
Nominal voltage, cable | 600 V AC (Core-ground, U0) |
Nominal voltage, cable | 1000 V AC (Core-ground, U) |
Nominal voltage, cable | ≤ 720 V AC (core-ground) |
Nominal voltage, cable | ≤ 1200 V AC (Core-ground, Um) |
Nominal voltage, cable | ≤ 900 V DC (Core-ground, V0) |
Nominal voltage, cable | ≤ 1500 V DC (Line-line) |
Test voltage | 3500 V AC (50 Hz, 5 min.) |
Test voltage | 8400 V DC (50 Hz, 5 min.) |
Minimum bending radius, fixed installation | 3 x D |
Minimum bending radius, flexible installation | 4 x D |
Smallest bending radius, fixed installation | 17 mm |
Smallest bending radius, movable installation | 22 mm |
Halogen-free | in accordance with EN 50267-2-1 |
Flame resistance | EN 60332-1-2 |
Flame resistance | EN 50266 |
Flame resistance | EN 50305, 9.1.2 |
Flame resistance | NF C32-070, 2.1 |
Flame resistance | NF C32-070, 2.2 |
Flame resistance | UL 1685, 12 (FT4) |
Flame resistance | in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01) |
Fume corrosiveness | EN 50267-2-2 |
Fume toxicity | BS 6853 B.1 |
Fume toxicity | EN 50305, 9.2 |
Concentration of fumes | BS 6853 D.8.7 |
Concentration of fumes | EN 61034-2 |
Concentration of fumes | UL 1685, 12 (FT4) |
Resistance to Oil | according to IRM 902, 72 h at 100 °C |
Fire protection in rail vehicles | BS 6853 (Category Ia, Ib, II) |
Fire protection in rail vehicles | GM/RT 2130 (Category Ia, Ib, II) |
Fire protection in rail vehicles | EN 45545 (Risk level HL1 - HL3) |
Fire protection in rail vehicles | DIN 5510 (Fire protection level 1, 2, 3, 4) |
Fire protection in rail vehicles | NF F16-101 (Category A1, A2, B) |
Fire protection in rail vehicles | NF F16-101 (Class C/F0) |
Fire protection in rail vehicles | NFPA 130 |
Fire protection in rail vehicles | UNI CEI 11170 (Risk level LR1 - LR4) |
Other resistance | Resistance to fuels (according to IRM 903, 168 h at 70 °C) |
Ambient Temperature (Operation) | -50 °C ... 120 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -25 °C ... 90 °C (Cable, flexible installation) |
Why Proax for Phoenix Contact 1058904?
Proax is an authorized distributor of Phoenix Contact 1058904 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended