Official Distributor
SKU
MPN
1049299
Weight
1.83 kg
Series SAC-2P
SAC-2P-MS/39,45-29R SCO RAIL - Sensor/actuator cable
Sensor/actuator cable, 2-position, PE-X halogen-free, black, shielded (Tinned copper braided shield), Plug straight M12 SPEEDCON, coding: A, on free cable end, cable length: 39.45 m, For railway applications
Technical Specifications
Product properties
Number of Positions | 2 |
Electrical properties
Nominal voltage UN | 48 V AC |
Nominal voltage UN | 60 V DC |
Connection 1
Type | Plug straight M12 SPEEDCON |
Locking Type | SPEEDCON |
Coding type | A |
Connection 2
Type | free cable end |
Cable/line
Cable Length | 39.45 m |
RADOX® black shielded 0.75 mm² [29R]
Cable weight | 48 kg/km |
Number of Positions | 2 |
Shielded | yes |
Cable Type | RADOX® black shielded 0.75 mm² [29R] |
Conductor structure signal line | 19x 0.22 mm |
AWG Signal Line | 18 |
Conductor Cross Section | 2x 0.75 mm² |
Wire diameter incl. insulation | 1.63 mm |
External Cable Diameter | 5.00 mm ±0.3 mm |
Outer sheath, material | PE-X |
External sheath, color | black |
Conductor material | Tin-plated Cu litz wires |
Material wire insulation | PE-X |
Single wire, color | white 1, white 2 |
Overall twist | 2 wires, twisted |
Max. conductor resistance | ≤ 26.7 Ω/km |
Nominal voltage, cable | 600 V AC (Core-ground, U0) |
Nominal voltage, cable | 1000 V AC (Core-ground, U) |
Nominal voltage, cable | ≤ 720 V AC (core-ground) |
Nominal voltage, cable | ≤ 1200 V AC (Core-ground, Um) |
Nominal voltage, cable | ≤ 900 V DC (Core-ground, V0) |
Nominal voltage, cable | ≤ 1500 V DC (Line-line) |
Test voltage | 3500 V AC (50 Hz, 5 min.) |
Test voltage | 8400 V DC (50 Hz, 5 min.) |
Minimum bending radius, fixed installation | 3 x D |
Minimum bending radius, flexible installation | 4 x D |
Smallest bending radius, fixed installation | 15 mm |
Smallest bending radius, movable installation | 20 mm |
Halogen-free | in accordance with EN 50267-2-1 |
Flame resistance | EN 60332-1-2 |
Flame resistance | EN 50266 |
Flame resistance | EN 50305, 9.1.2 |
Flame resistance | NF C32-070, 2.1 |
Flame resistance | NF C32-070, 2.2 |
Flame resistance | UL 1685, 12 (FT4) |
Flame resistance | in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01) |
Fume corrosiveness | EN 50267-2-2 |
Fume toxicity | BS 6853 B.1 |
Fume toxicity | EN 50305, 9.2 |
Concentration of fumes | BS 6853 D.8.7 |
Concentration of fumes | EN 61034-2 |
Concentration of fumes | UL 1685, 12 (FT4) |
Resistance to Oil | according to IRM 902, 72 h at 100 °C |
Fire protection in rail vehicles | BS 6853 (Category Ia, Ib, II) |
Fire protection in rail vehicles | GM/RT 2130 (Category Ia, Ib, II) |
Fire protection in rail vehicles | EN 45545 (Risk level HL1 - HL3) |
Fire protection in rail vehicles | DIN 5510 (Fire protection level 1, 2, 3, 4) |
Fire protection in rail vehicles | NF F16-101 (Category A1, A2, B) |
Fire protection in rail vehicles | NF F16-101 (Class C/F0) |
Fire protection in rail vehicles | NFPA 130 |
Fire protection in rail vehicles | UNI CEI 11170 (Risk level LR1 - LR4) |
Other resistance | Resistance to fuels (according to IRM 903, 168 h at 70 °C) |
Ambient Temperature (Operation) | -50 °C ... 120 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -25 °C ... 90 °C (Cable, flexible installation) |
Why Proax for Phoenix Contact SAC-2P-MS/39,45-29R SCO RAIL?
Proax is an authorized distributor of Phoenix Contact SAC-2P-MS/39,45-29R SCO RAIL and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | SAC2PMS394529RSCORAIL |
Pack Size | 1 |
Recommended