Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
NBC-M12MSX/ 0,3-94F/R4AC
Weight
0.049 kg
Series NBC-M

NBC-M12MSX/ 0,3-94F/R4AC - Network cable

Network cable, Ethernet CAT6A (10 Gbps), CC-Link IE CAT6A (10 Gbps), 8-position, PUR halogen-free, water blue RAL 5021, shielded (Tinned copper braided shield), Advanced Shielding Technology, Plug straight M12, coding: X / IP67, on Plug straight RJ45 / IP20, cable length: 0.3 m

Technical Specifications

Product properties

ApplicationStandard
Sensor TypeEthernet
Number of Positions8
No. of cable outlets1
Shieldedyes
CodingX

Interfaces

Bus systemEthernet
Signal type/categoryEthernet CAT6A, 10 Gbps
Signal type/categoryCC-Link IE CAT6A, 10 Gbps

Signaling

Status displayNo
Status display presentNo

Electrical properties

Nominal voltage UN48 V AC
Nominal voltage UN60 V DC
Nominal current IN0.5 A
Transmission mediumCopper
Transmission characteristics (category)CAT6A

Connection 1

TypePlug straight M12 / IP67
Number of Positions8
Coding typeX (Data)
Handle colorblack
MaterialCuZn (Contact)
MaterialNi/Au (Contact surface)
MaterialPP (Contact carriers)
MaterialTPU, hardly inflammable, self-extinguishing (Grip)
MaterialZinc die-cast, nickel-plated (Screw connection)
Insertion/withdrawal cycles≥ 100
Insulation resistance≥ 100 MΩ
Degree of ProtectionIP67

Connection 2

TypePlug straight RJ45 / IP20
Number of Positions8
Handle colorgray
MaterialCuSn (Contact)
MaterialNi/Au (Contact surface)
MaterialPC (Contact carriers)
MaterialPA (Housing)
Insertion/withdrawal cycles≥ 750
Insulation resistance≥ 100 MΩ
Tightening torque0.4 Nm
Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 60 °C

Cable/line

Cable Length0.3 m

Ethernet 10 Gbit [94F]

Cable weight42 kg/km
UL AWM style20963 (80°C/30 V)
Number of Positions8
Shieldedyes
Cable TypeEthernet 10 Gbit [94F]
Conductor structure4x2xAWG26/7; S/FTP
Signal runtime5.13 ns/m
Conductor structure signal line7x 0.16 mm
AWG Signal Line26
Conductor Cross Section4x 2x 0.14 mm²
Wire diameter incl. insulation1.04 mm
External Cable Diameter6.40 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorwater blue RAL 5021
Conductor materialBare Cu litz wires
Material wire insulationFoamed PE
Single wire, colorwhite/blue-blue, white/orange-orange, white/green-green, white/brown-brown
Thickness, outer sheath0.65 mm
Twisted pairs2 cores to the pair
Type of pair shieldingAluminum-lined foil
Overall twist4 pairs for core
Optical shield covering70 %
Insulation resistance≥ 500 MΩ*km
Loop resistance≤ 290.00 Ω/km
Wave impedance100 Ω ±5 Ω (at 100 MHz)
Cable capacity47 nF/km
Nominal voltage, cable≤ 100 V
Test voltage Core/Core700 V (50 Hz, 1 min.)
Test voltage Core/Shield700.00 V (50 Hz, 1 min.)
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation8 x D
Smallest bending radius, fixed installation26 mm
Smallest bending radius, movable installation52 mm
Tensile strength≤ 100 N
Near end crosstalk attenuation (NEXT)75.3 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)66.3 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)61.8 dB (at 8 МHz)
Near end crosstalk attenuation (NEXT)60.3 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)57.2 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)55.8 dB (at 20 МHz)
Near end crosstalk attenuation (NEXT)54.3 dB (at 25 MHz)
Near end crosstalk attenuation (NEXT)52.8 dB (at 31.25 МHz)
Near end crosstalk attenuation (NEXT)48.4 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)45.3 dB (at 100 MHz)
Near end crosstalk attenuation (NEXT)40.8 dB (at 200 MHz)
Near end crosstalk attenuation (NEXT)39.3 dB (at 250 MHz)
Near end crosstalk attenuation (NEXT)38.1 dB (at 300 MHz)
Near end crosstalk attenuation (NEXT)38.1 dB (at 400 MHz)
Near end crosstalk attenuation (NEXT)38.1 dB (at 500 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)72.3 dB (with 1 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)63.3 dB (at 4 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)58.8 dB (at 8 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)57.3 dB (at 10 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)54.2 dB (at 16 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)52.8 dB (at 20 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)51.3 dB (at 25 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)49.9 dB (at 31.25 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)45.4 dB (at 62.5 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)42.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)37.8 dB (at 200 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)36.3 dB (at 250 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)35.1 dB (at 300 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)33.3 dB (at 400 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)31.8 dB (at 500 MHz)
Return attenuation (RL)20 dB (with 1 MHz)
Return attenuation (RL)23 dB (at 4 МHz)
Return attenuation (RL)24.5 dB (at 8 МHz)
Return attenuation (RL)25 dB (at 10 MHz)
Return attenuation (RL)25 dB (at 16 MHz)
Return attenuation (RL)25 dB (at 20 МHz)
Return attenuation (RL)24.2 dB (at 25 MHz)
Return attenuation (RL)23.3 dB (at 31.25 МHz)
Return attenuation (RL)20.7 dB (at 62.5 МHz)
Return attenuation (RL)19 dB (at 100 MHz)
Return attenuation (RL)16.4 dB (at 200 MHz)
Return attenuation (RL)15.6 dB (at 250 MHz)
Return attenuation (RL)15.6 dB (at 300 MHz)
Return attenuation (RL)15.6 dB (at 400 MHz)
Return attenuation (RL)15.6 dB (at 500 MHz)
Shield attenuation3.1 dB (with 1 MHz)
Shield attenuation5.7 dB (at 4 МHz)
Shield attenuation8 dB (at 8 МHz)
Shield attenuation8.9 dB (at 10 MHz)
Shield attenuation11.2 dB (at 16 MHz)
Shield attenuation12.6 dB (at 20 МHz)
Shield attenuation14.1 dB (at 25 MHz)
Shield attenuation15.8 dB (at 31.25 МHz)
Shield attenuation22.5 dB (at 62.5 МHz)
Shield attenuation28.7 dB (at 100 MHz)
Shield attenuation41.4 dB (at 200 MHz)
Shield attenuation46.6 dB (at 250 MHz)
Shield attenuation51.4 dB (at 300 MHz)
Shield attenuation60.1 dB (at 400 MHz)
Shield attenuation67.9 dB (at 500 MHz)
Shield attenuation≥ 80.00 dB (at 30 ... 100 MHz)
Halogen-freeaccording to IEC 60754-1
Flame resistanceaccording to IEC 60332-1-2
Resistance to Oilin accordance with DIN EN 60811-2-1
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-20 °C ... 80 °C (Cable, flexible installation)
Ambient temperature (installation)-20 °C ... 80 °C

Ambient conditions

Degree of ProtectionIP65 (M12 connector)
Degree of ProtectionIP67 (M12 connector)
Degree of ProtectionIP20 (RJ45 connector)
Ambient Temperature (Operation)-25 °C ... 90 °C (M12 connector)
Ambient Temperature (Operation)-20 °C ... 70 °C (RJ45 connector)

M12

Standard designationM12 connector
Standards/specificationsIEC 61076-2-109

Why Proax for Phoenix Contact 1002933?

Proax is an authorized distributor of Phoenix Contact 1002933 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability