By Phoenix Contact

SKU
MPN
DEK-OV- 12DC/240AC/800
Weight
0.021 kg
Series DEK-OV

DEK-OV- 12DC/240AC/800 - Solid-state relay terminal block

Power solid-state relay terminal block, input: 12 V DC, output: 10 - 253 V AC/800 mA, terminal block width: 6.2 mm

  • EB-DIK insertion bridges
  • Actuator version available
  • Labeling and mounting with user-friendly modular terminal blocks
  • Wear-free switching of up to 24 V DC/10 A or 240 V AC/800 mA
  • Integrated output protective circuit
  • Electrical isolation between input and output at up to 2.5 kVrms
  • Zero voltage switch at AC output
  • Status indicator
  • Integrated input circuit
Technical Specifications

Notes

Order information:The housing is open on one side. The appropriate cover is D-DEK 1,5 GN (2716949).
Note on applicationUse of EB 80-DIK... bridges in the DEK terminal blocks: Absorption of humidity from the ambient air as well as an unfavorable tolerance between a larger number of DEK terminal blocks and the EB 80-DIK... bridge may cause (minor) expansion of the DEK housing. When the EB 80-DIK... bridges are used, therefore, it is recommended that these be disconnected after about 10 to 12 DEK terminal blocks and a wire bridge to the next DEK terminal block be inserted in their place.

Product properties

Product familyDEK
ApplicationOutput function
Operating mode100% operating factor

Insulation characteristics

InsulationBasic insulation

Insulation characteristics: Standards/regulations

InsulationBasic insulation
Overvoltage categoryIII
Pollution degree2

Electrical properties

Test voltage (Input/output)2.5 kV AC (Input/output)

Input data

Nominal input voltage UN12 V DC
Input voltage range in reference to UN0.8 ... 1.2
Input voltage range9.6 V DC ... 14.4 V DC
Switching threshold "0" signal in reference to UN≤ 0.4
Switching threshold "1" signal in reference to UN≥ 0.8
Typical input current at UN10.5 mA
Typical response time< 10 ms
Typical turn-off time< 10 ms
Operating voltage displayYellow LED
Protective circuitReverse polarity protection; Polarity protection diode
Protective circuitSurge protection
Transmission frequency10 Hz

Output data

Contact switching type1 N/O contact
Design of digital outputelectronic
Output voltage range10 V AC ... 253 V AC (50/60 Hz)
Limiting Continuous Current0.8 A (see derating curve)
Maximum Inrush Current30 A (t = 10 ms)
Min. load current10 mA
Leakage current1.2 mA (in off state)
Phase angle cos phi min0.5
Max. load value4.5 A2s
Peak offstate voltage600 V (Periodic peak reverse voltage)
Voltage drop at max. limiting continuous current≤ 1 V
Output circuit2-conductor floating, zero voltage switch
Protective circuitRCV circuit; RCV circuit

Connection data

Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm

Dimensions

Width6.2 mm
Height80 mm
Depth56 mm

Material specifications

Colorgreen (RAL 6021)

Ambient conditions

Ambient Temperature (Operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-20 °C ... 70 °C

Standards/regulations

Standards/regulationsIEC 60947-5-1

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany
Accessories

Why Proax for Phoenix Contact 2964636?

Proax is an authorized distributor of Phoenix Contact 2964636 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size10
Recommended
Sold in quantities of 10

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability