2902647
SKU
PHX2902647
MPN
RIF-T3-24UC
Weight
0.006 kg
RIF-T3-24UC - Timer module
Plug-in module for extending a relay module to create a timer relay, 3 time functions, 4 time ranges, for mounting on RIF-1, RIF-2, RIF-3, and RIF-4, input voltage: 12 V DC ... 24 V DC
Technical Specifications
Utilization restriction
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product properties
| Product family | RIFLINE complete |
Insulation characteristics
| Insulation | Basic insulation |
Insulation characteristics: Air clearances and creepage distances in a circuit
| Insulation | Basic insulation |
| Overvoltage category | I |
| Pollution degree | 2 |
Electrical properties
| Setting accuracy | 3 % (of scale end value) |
| Nominal voltage UN | 24 V AC/DC |
| Repeat accuracy | 1 % |
Air clearances and creepage distances in a circuit
| Rated Insulation Voltage | 50 V DC |
| Rated surge voltage | 0.4 kV |
Input data
| Nominal input voltage UN | 24 V DC (AC operation only permitted for RIF-1) |
| Input voltage range in reference to UN | 0.4 ... 1.2 |
| Mains frequency | 50 Hz |
| Mains frequency | 60 Hz |
| Status display | Yellow LED |
| Protective circuit | Varistor |
| Surge voltage protection | > 56 V |
Output data
| Limiting Continuous Current | ≤ 250 mA (Relay coil current) |
| Voltage drop at max. limiting continuous current | < 100 mV |
Dimensions
| Width | 13 mm |
| Height | 12 mm |
| Depth | 35 mm |
Ambient conditions
| Ambient Temperature (Operation) | -25 °C ... 50 °C (RIF-1, AC coil, 2 changeover contacts at 6 A) |
| Ambient Temperature (Operation) | -25 °C ... 50 °C (RIF-1, DC coil, 2 changeover contacts at 5 A) |
| Ambient Temperature (Operation) | -25 °C ... 40 °C (RIF-2, DC coil, 2 changeover contacts at 8 A) |
| Ambient Temperature (Operation) | -25 °C ... 40 °C (RIF-2, DC coil, 4 changeover contacts at 5 A) |
| Ambient Temperature (Operation) | -25 °C ... 40 °C (RIF-3, DC coil, 3 changeover contacts at 6.75 A) |
| Ambient Temperature (Operation) | -25 °C ... 40 °C (RIF-3, DC coil, 2 changeover contacts at 8 A) |
| Ambient Temperature (Operation) | -25 °C ... 35 °C (RIF-4, DC coil, 3 changeover contacts at 8 A) |
| Ambient Temperature (Operation) | -25 °C ... 25 °C (RIF-4, DC coil, 3 N/O contacts at 8 A) |
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
UKCA
| Certificate | UKCA-compliant |
Corrosive gas test
| Identification | ISA-S71.04. G3 Harsh Group |
| Identification | EN 60068-2-60 |
Air clearances and creepage distances in a circuit
| Standards/regulations | IEC 60947-5-1 |
Mounting
| Assembly instructions | Can be inserted into relay base |
| Mounting Position | any |
Why Proax for Phoenix Contact 2902647?
Proax is an authorized distributor of Phoenix Contact 2902647 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.