CADEN
Cart

2882572

Official Distributor

By Phoenix Contact

SKU
PHX2882572
MPN
S-PT-EX(I)-24DC-1/2"
Weight
0.434 kg

S-PT-EX(I)-24DC-1/2" - Surge protection device

Surge protection in the IP67 screw-on module for measuring sensors in intrinsically safe circuits, direct mounting with 1/2" NPT outer thread, cable gland for the signal cable, two-stage protective circuit. HART-compatible.

  • Easiest field mounting with standardized thread
  • Versatile in use with universal protective circuit
  • Use under extreme ambient conditions with robust design
Technical Specifications

Notes

Notes on operationWhen the bridge is disconnected, the shield connection is indirectly connected to the housing or reference potential.

Product properties

Product familySURGETRAB
IEC test classificationC1
IEC test classificationC2
IEC test classificationC3
IEC test classificationD1
TypeScrew-in module
Number of Positions3
Surge protection fault messagenone
Wire pairs per module1

Insulation characteristics

Overvoltage categoryIII
Pollution degree2

Electrical properties

Nominal voltage UN24 V DC

Connection data

Connection MethodScrew connection
Screw threadM3
Tightening torque0.6 Nm
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Conductor cross section AWG26 ... 16

Ex data

Maximum inner capacitance Ci2 nF
Max. internal inductance Li1 µH
Max. input current Ii350 mA (T4 / ≤ 50 °C)
Max. input current Ii350 mA (T5 / ≤ 50 °C)
Max. input current Ii350 mA (T6 / ≤ 50 °C)
Max. input voltage Ui30 V
max. input power Pi3.00 W
Insulation voltage to ground500 V AC
Ambient Temperature (Operation)-40 °C ... 50 °C
Max. surface temperature135 °C (T4)
Max. surface temperature100 °C (T5)
Max. surface temperature85 °C (T6)

Dimensions

Width33.5 mm
Height33.5 mm
Depth148 mm

Material specifications

ColorSteel / stainless steel
Housing MaterialZinc die-cast, surface bronzed and nickel-plated
Housing surface materialnickel-plated

Mechanical data

Open side panelNo

Protective circuit

Direction of actionLine-Line & Line-Earth Ground
Maximum continuous voltage UC30 V DC
Maximum continuous voltage UC21 V AC
Rated current350 mA (50 °C)
Operating effective current IC at UC≤ 10 µA
Residual current IPE≤ 2 µA
Nominal discharge current In (8/20) µs (line-line)10 kA
Nominal discharge current In (8/20) µs (line-ground)10 kA (per path)
Nominal discharge current In (8/20) µs (shield-ground)10 kA (optional)
Pulse discharge current Iimp (10/350) µs1 kA
Max. discharge current Imax (8/20) µs maximum (line-line)10 kA
Max. discharge current Imax (8/20) µs maximum (line-earth)10 kA (per path)
Discharge surge current Imax (8/20) µs maximum (shield-ground)10 kA
Nominal pulse current Ian (10/1000) µs (line-line)30 A
Nominal pulse current Ian (10/1000) µs (line-earth)100 A (per path)
Nominal pulse current Ian (10/1000) µs (shield-ground)100 A
Output voltage limitation at 1 kV/µs (line-line) spike≤ 50 V
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 1.4 kV (Direct grounding)
Output voltage limitation at 1 kV/µs (shield-ground) spike≤ 600 V (optional)
Output voltage limitation at 1 kV/µs (line-line) static≤ 50 V
Output voltage limitation at 1 kV/µs (line-earth) static≤ 1.4 kV (Direct grounding)
Residual voltage at In (conductor-conductor)≤ 50 V
Residual voltage with Ian (10/1000) µs (line-line)≤ 50 V
Voltage protection level Up (line-line)≤ 50 V (C1 - 0.5 kV / 250 A)
Voltage protection level Up (line-line)≤ 55 V (C1 - 1 kV / 500 A)
Voltage protection level Up (line-line)≤ 55 V (C2 - 2 kV/1 kA)
Voltage protection level Up (line-line)≤ 55 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-line)≤ 50 V (C3 - 10 A)
Voltage protection level Up (line-line)≤ 50 V (C3 - 25 A)
Voltage protection level Up (line-line)≤ 80 V (D1 - 1 kA)
Voltage protection level Up (line-earth)≤ 1.4 kV (C1 - 1 kV / 500 A)
Voltage protection level Up (line-earth)≤ 1.4 kV (C2 - 2 kV/1 kA)
Voltage protection level Up (line-earth)≤ 1.4 kV (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-earth)≤ 1.4 kV (C3 - 25 A)
Voltage protection level Up (line-earth)≤ 1.4 kV (C3 - 100 A)
Voltage protection level Up (line-earth)≤ 1.4 kV (D1 - 1 kA)
Voltage protection level Up (shield-ground)≤ 600 V (C1 - 0.5 kV / 250 A)
Voltage protection level Up (shield-ground)≤ 650 V (C1 - 1 kV / 500 A)
Voltage protection level Up (shield-ground)≤ 650 V (C2 - 2 kV/1 kA)
Voltage protection level Up (shield-ground)≤ 650 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (shield-ground)≤ 650 V (C3 - 10 A)
Voltage protection level Up (shield-ground)≤ 750 V (C3 - 25 A)
Voltage protection level Up (shield-ground)≤ 750 V (C3 - 100 A)
Voltage protection level Up (shield-ground)≤ 650 V (D1 - 1 kA)
Response time tA (line-line)≤ 1 ns
Response time tA (line-earth)≤ 100 ns
Response time tA (shield-ground)≤ 100 ns
Input attenuation aE, sym.typ. 0.5 dB (≤ 1 MHz / 50 Ω)
Input attenuation aE, sym.typ. 0.2 dB (≤ 400 kHz / 150 Ω)
Cut-off frequency fg (3 dB), sym. in 50 Ω systemtyp. 6 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ω systemtyp. 2.5 MHz
Resistance per path2.2 Ω ±10 %
Surge protection fault messagenone
Impulse durability (line-line)C1 - 1 kV / 500 A
Impulse durability (line-line)C2 - 10 kV / 5 kA
Impulse durability (line-line)C3 - 25 A
Impulse durability (line-line)D1 - 1 kA
Impulse durability (line-earth)C1 - 1 kV / 500 A
Impulse durability (line-earth)C2 - 10 kV / 5 kA
Impulse durability (line-earth)C3 - 100 A
Impulse durability (line-earth)D1 - 1 kA
Impulse durability (shield-ground)C1 - 1  kV/500 A
Impulse durability (shield-ground)C2 - 10 kV/5 kA
Impulse durability (shield-ground)C3 - 100 A
Impulse durability (shield-ground)D1 - 1 kA
Alternating current carrying capacity (line-earth)10 A - 1 s
Alternating current carrying capacity (shield-ground)10 A - 1 s

Ambient conditions

Degree of ProtectionIP67
Ambient Temperature (Operation)-40 °C ... 50 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m (amsl)

Conformity/Approvals

ATEX II 1G Ex ia IIC T4...T6 Ga
IECExEx ia IIC T4...T6 Ga

Air clearances and creepage distances

Standards/regulationsIEC 60664-1 / EN 60079-0 / EN 60079-11
Standards/specificationsEN 61643-21
NoteA2:2013
Standards/specificationsEN 60079-0
Note2018
Standards/specificationsEN 60079-11
Note2012
Standards/specificationsIEC 60079-0
Note2017
Standards/specificationsIEC 60079-11
Note2011

Mounting

Mounting Typedirect screw connection

Why Proax for Phoenix Contact 2882572?

Proax is an authorized distributor of Phoenix Contact 2882572 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size1
Recommended

CAD$491.74

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability