Official Distributor
SKU
MPN
IL MOD BK DI8 DO4-PAC
Weight
0.321 kg
This product is Not Cancellable/Not Returnable
IL MOD BK DI8 DO4-PAC - Bus coupler
Inline, Bus coupler, Modbus/RTU, D-SUB-9 female connector, Digital inputs: 8, 24 V DC, connection technology: 3-conductor, Digital outputs: 4, 24 V DC, 500 mA, connection technology: 3-conductor, transmission speed in the local bus: 500 kbps / 2 Mbps, degree of protection: IP20, including inline connectors, marking fields, and end plate
- Modbus connection via 9-pos. D-SUB socket
- Electrical isolation between Modbus interface and logic
- 8 digital inputs, 4 digital outputs (on-board)
- Data transmission speed in Modbus of 1.2 kbps to 115.2 kbps (configurable)
- Rotary coding switches for setting the Modbus address and for configuration
- Supported Modbus addresses from 1 to 99
- Automatic detection of the transmission speed in the local bus (500 kbps or 2 Mbps)
- Shipbuilding and UL approvals
Technical Specifications
Dimensions
Width | 80 mm |
Height | 119.8 mm |
Depth | 71.5 mm |
Note on dimensions | Specfications with connectors |
Utilization restriction
CCCex note | Use in potentially explosive areas is not permitted in China. |
Number of interfaces | 1 |
Connection Method | D-SUB-9 female connector |
Note on the connection method | Electrically isolated supply, shielding directly connected to functional ground |
Transmission Speed | 1.2 kBit/s ... 115.2 kBit/s (can be parameterized) |
Inline local bus
Number of interfaces | 1 |
Connection Method | Inline data jumper |
Transmission Speed | 500 kbps / 2 Mbps (automatic detection, no combined system) |
System limits
Number of supported devices | max. 63 (per station) |
Number of local bus devices that can be connected | max. 61 (The on-board I/Os are two devices) |
Number of devices with parameter channel | max. 8 |
Number of supported branch terminals with remote bus branch | 0 |
Module
ID code (hex) | none |
Input address area | 8 bit |
Output address area | 4 bit |
Register length | 16 bit |
Digital:
Input name | Digital inputs |
Description of the input | EN 61131-2 type 1 |
Number of Inputs | 8 |
Connection Method | Inline connector |
Connection technology | 3-conductor |
Input Voltage | 24 V DC |
Input voltage range "0" signal | -30 V DC ... 5 V DC |
Input voltage range "1" signal | 15 V DC ... 30 V DC |
Nominal input voltage UIN | 24 V DC |
Nominal input current at UIN | typ. 3 mA |
Typical input current per channel | typ. 3 mA |
Typical response time | approx. 500 µs |
Delay at signal change from 0 to 1 | 1.2 ms |
Delay at signal change from 1 to 0 | 1.2 ms |
Output name | Digital outputs |
Connection Method | Inline connector |
Connection technology | 3-conductor |
Number of Outputs | 4 |
Protective circuit | Short-circuit and overload protection; Freewheeling circuit in the output driver |
Output Voltage | 24 V DC -1 V (At nominal current) |
Maximum Output Current per module | max. 2 A |
Nominal Output Voltage | 24 V DC |
Output current when switched off | max. 10 µA (When not loaded, a voltage can be measured even at an output that is not set.) |
Nominal load, inductive | 12 VA (1.2 H, 48 Ω) |
Nominal load, lamp | 12 W |
Nominal load, ohmic | 12 W |
Reverse voltage resistance to short pulses | Reverse voltage proof |
Behavior with overload | Auto restart |
Behavior with inductive overload | Output can be destroyed |
Behavior at voltage switch-off | The output follows the power supply without delay |
Signal delay | typ. 1.2 ms |
Overcurrent shut-down | min. 0.7 A |
Product properties
Product family | Inline |
Type | modular |
Scope of delivery | including inline connectors, marking fields, and end plate |
No. of channels | 12 |
Diagnostics messages | Short-circuit or overload of the digital outputs yes |
Diagnostics messages | Sensor supply failure yes |
Diagnostics messages | Failure of the actuator supply yes |
Insulation characteristics
Overvoltage category | II (IEC 60664-1, EN 60664-1) |
Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
Electrical properties
Maximum power dissipation for nominal condition | 23.5 W |
Potentials
Power consumption | typ. 3 W (entire device) |
Supply Voltage | 24 V DC (via Inline connector) |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 0.94 A (with max. number of connected I/O terminal blocks) |
Current draw | typ. 40 mA (without connected I/O terminal blocks) |
Potentials: Communications power (UL)
Supply Voltage | 7.5 V DC |
Potentials: Supply of analog modules (UANA)
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Potentials: Main circuit supply (UM)
Supply Voltage | 24 V DC (via Inline connector) |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 8 A DC |
Current draw | min. 3 mA (without connected peripherals) |
Potentials: Segment circuit supply (US)
Supply Voltage | 24 V DC (via Inline connector) |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 8 A DC |
Current draw | min. 3 mA (without connected peripherals) |
Electrical isolation/isolation of the voltage ranges
Test voltage: Modbus interface 1 / Modbus interface 2 | 500 V AC, 50 Hz, 1 min. |
Test voltage: Modbus interface 1 / communications power (UBK, UL, UANA) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Modbus interface 1 / I/O (UM, US) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Modbus interface 1 / functional ground | 500 V AC, 50 Hz, 1 min. |
Test voltage: Modbus interface 2 / communications power (UBK, UL, UANA) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Modbus interface 2 / I/O (UM, US) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Modbus interface 2 / functional ground | 500 V AC, 50 Hz, 1 min. |
Test voltage: Communications power (UBK, UL, UANA) / I/O (UM, US) | 500 V AC, 50 Hz, 1 min. |
Test voltage: Communications power (UBK, UL, UANA) / functional ground | 500 V AC, 50 Hz, 1 min. |
Test voltage: I/O (UM, US) / functional ground | 500 V AC, 50 Hz, 1 min. |
Connection technology
Connection name | Inline connector |
Conductor connection
Connection Method | Spring-cage connection |
Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm |
Inline connector
Connection Method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 60 °C |
Degree of Protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
Standards and Regulations
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting
Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 2878696?
Proax is an authorized distributor of Phoenix Contact 2878696 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |