Official Distributor
SKU
MPN
VIP-CAB-FLK40/FS/NA/HF/ 5,0M
Weight
0.765 kg
Series VIP-CAB-FLK
VIP-CAB-FLK40/FS/NA/HF/ 5,0M - Cable
Assembled, shielded, halogen-free round cable; connection 1: IDC/FLK socket strip (1x 40-position, 180 °-out put); connection 2: Single wires (40-position); cable length: 5 m
Technical Specifications
Insulation characteristics
Insulation | Functional insulation |
Insulation characteristics: Air clearances and creepage distances
Insulation | Functional insulation |
Overvoltage category | II |
Pollution degree | 2 |
Ambient conditions
Degree of Protection | IP00 |
Degree of protection (Installation location) | ≥ IP54 (Installation location) |
Ambient Temperature (Operation) | -40 °C ... 70 °C (fixed installation) |
Ambient Temperature (Operation) | -10 °C ... 70 °C (flexible installation) |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m |
Electrical properties
Operating voltage (AC) | ≤ 25 V AC |
Operating voltage (DC) | ≤ 60 V DC |
Nominal operating mode | 100% operating factor |
Current (Per path, 50°C) | ≤ 1 A |
Current (Per path) | ≤ 0.6 A |
Air clearances and creepage distances
Rated Insulation Voltage | 63 V |
Rated surge voltage | 0.6 kV |
Cable/line
Cable Length | 5 m |
Number of Positions | 40 |
Shielded | yes |
Conductor type | Assembled, shielded, halogen-free round cable |
Conductor structure signal line | 7x 0.16 mm |
AWG Signal Line | 26 |
Conductor Cross Section | 40x 0.14 mm² |
Wire diameter incl. insulation | 1 mm ±0.03 mm |
External Cable Diameter | 9.80 mm ±0.4 mm |
Outer sheath, material | Halogen-free sheath |
External sheath, color | gray |
Conductor material | Tin-plated Cu litz wires |
Cable resistance | ≤ 145 Ω/km |
Insulation resistance | ≥ 20 MΩ*km |
Smallest bending radius, fixed installation | 102 mm |
Smallest bending radius, movable installation | 184 mm |
Max. bending cycles | 5000 |
Halogen-free | yes |
Flame resistance | IEC 60332-1-2 (raw cable) |
Flame resistance | VDE 0842, Part 332-1-2 (raw cable) |
Flame resistance | IEC 60332-3-22 (raw cable) |
Resistance to Oil | can withstand occasional splashes (raw cable) |
IDC/FLK50 (1) | IDC/FLK50 (1) = black |
IDC/FLK50 (2) | IDC/FLK50 (2) = brown |
IDC/FLK50 (3) | IDC/FLK50 (3) = red |
IDC/FLK50 (4) | IDC/FLK50 (4) = orange |
IDC/FLK50 (5) | IDC/FLK50 (5) = yellow |
IDC/FLK50 (6) | IDC/FLK50 (6) = green |
IDC/FLK50 (7) | IDC/FLK50 (7) = blue |
IDC/FLK50 (8) | IDC/FLK50 (8) = violet |
IDC/FLK50 (9) | IDC/FLK50 (9) = gray |
IDC/FLK50 (10) | IDC/FLK50 (10) = white |
IDC/FLK50 (11) | IDC/FLK50 (11) = white-black |
IDC/FLK50 (12) | IDC/FLK50 (12) = white-brown |
IDC/FLK50 (13) | IDC/FLK50 (13) = white-red |
IDC/FLK50 (14) | IDC/FLK50 (14) = white-orange |
IDC/FLK50 (15) | IDC/FLK50 (15) = white-yellow |
IDC/FLK50 (16) | IDC/FLK50 (16) = white-green |
IDC/FLK50 (17) | IDC/FLK50 (17) = white-blue |
IDC/FLK50 (18) | IDC/FLK50 (18) = white-violet |
IDC/FLK50 (19) | IDC/FLK50 (19) = white-gray |
IDC/FLK50 (20) | IDC/FLK50 (20) = brown-black |
IDC/FLK50 (21) | IDC/FLK50 (21) = brown-red |
IDC/FLK50 (22) | IDC/FLK50 (22) = brown-orange |
IDC/FLK50 (23) | IDC/FLK50 (23) = brown-yellow |
IDC/FLK50 (24) | IDC/FLK50 (24) = brown-green |
IDC/FLK50 (25) | IDC/FLK50 (25) = brown-blue |
IDC/FLK50 (26) | IDC/FLK50 (26) = brown-violet |
IDC/FLK50 (27) | IDC/FLK50 (27) = brown-gray |
IDC/FLK50 (28) | IDC/FLK50 (28) = brown-white |
IDC/FLK50 (29) | IDC/FLK50 (29) = green-black |
IDC/FLK50 (30) | IDC/FLK50 (30) = green-brown |
IDC/FLK50 (31) | IDC/FLK50 (31) = green-red |
IDC/FLK50 (32) | IDC/FLK50 (32) = green-orange |
IDC/FLK50 (33) | IDC/FLK50 (33) = green-blue |
IDC/FLK50 (34) | IDC/FLK50 (34) = green-violet |
IDC/FLK50 (35) | IDC/FLK50 (35) = green-gray |
IDC/FLK50 (36) | IDC/FLK50 (36) = green-white |
IDC/FLK50 (37) | IDC/FLK50 (37) = yellow-black |
IDC/FLK50 (38) | IDC/FLK50 (38) = yellow-brown |
IDC/FLK50 (39) | IDC/FLK50 (39) = yellow-red |
IDC/FLK50 (40) | IDC/FLK50 (40) = yellow-orange |
Cable Type | Cable for one module |
Field level
Connection Method | Single wires |
Number of Positions | 40 |
Controller level
Connection in acc. with standard | IEC 60603-13 |
Connection Method | IDC/FLK socket strip |
Number of Connections | 1 |
Number of Positions | 40 |
Exit angle | 180 ° |
Insertion/withdrawal cycles | > 50 |
Pitch | 2.54 mm |
Air clearances and creepage distances
Standards/regulations | DIN EN 50178 |
Notes
Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Why Proax for Phoenix Contact 2908835?
Proax is an authorized distributor of Phoenix Contact 2908835 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 2 |
Recommended