0.537 kg
Series ELR-H

ELR H5-IES-SC-SWD/500AC-9 - Démarreur moteur hybride

Démarreur moteur hybride pour l'inversion de moteurs AC triphasés jusqu'à 550 V AC, courant de sortie 9 A, coupure de surcharge réglable et arrêt d'urgence sécurisé jusqu'à PLe/SIL 3 et adaptateur SmartWire-DT™ en kit.

  • Largeur 22,5 mm
  • Niveau de sécurité conformément à CEI 61508-1 : SIL 3, ISO 13849 : PL e
  • Économies de câblage
  • Longue durée de vie
  • Gain de place
  • Courant réglable pour fonction bilame
  • Commutation à faible usure
Technical Specifications

Product properties

Product familyCONTACTRON
Operating mode100% operating factor

Electrical properties

Number of phases3
Motor starter typeReversing starter
Maximum power dissipation for nominal condition13.5 W
Switching frequency≤ 2 Hz (Load-dependent)
Maximum power dissipation7 W
Minimum power dissipation0.88 W
Coordination type1

Supply

Rated control circuit supply voltage US24 V DC
Control supply voltage range19.2 V DC ... 30 V DC
Rated control supply current IS40 mA
Protective circuitSurge protection
Protective circuitReverse polarity protection; Parallel polarity protection diode

Insulation characteristics

Rated Insulation Voltage500 V
Rated surge voltage6 kV
Overvoltage categoryIII
Degree of pollution2
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuitSafe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuitSafe isolation (EN 50178) at operating voltage ≤ 300 V AC
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuitBasic insulation (IEC 60947-1) at operating voltage 300 V AC ... 500 V AC
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuitSafe isolation (EN 50178) at operating voltage 300 ... 500 V AC
Isolation characteristics between the control input and control supply voltage to auxiliary circuitSafe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Isolation characteristics between the control input and control supply voltage to auxiliary circuitSafe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC

Emergency tripping

Operate threshold> 45 A
Response time< 2 s

Control

Input nameControl input right/left
Rated actuating voltage UC24 V DC
Triggering voltage range19.2 V DC ... 30 V DC
Rated actuating current IC5 mA
Switching threshold9.6 V (“0” signal)
Switching threshold19.2 V (“1” signal)
Switching level< 5 V DC (For EMERGENCY STOP)
Typical turn-off time< 30 ms

AC output

Rated operating voltage Ue500 V AC
Operating voltage range42 V AC ... 550 V AC
Mains frequency50/60 Hz
Load current range1.5 A ... 9 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2Class 10A
Cooling time20 min. (for auto reset)
Leakage current0 mA
Protective circuitSurge protection

Acknowledge output

NoteConfirmation: floating change-over contact, signal contact
Contact switching type1 changeover contact
Switching capacity in accordance with IEC 60947-5-13 A (230 V, AC15)
Switching capacity in accordance with IEC 60947-5-12 A (24 V, DC13)

Control circuits

Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm ... 0.6 Nm
Tightening torque5 lbf-in. ... 7 lbf-in.

Load circuit

Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm ... 0.6 Nm
Tightening torque5 lbf-in. ... 7 lbf-in.

Signaling

Status displayYellow LED
Operating voltage displayGreen LED
Error indicationRed LED

Dimensions

Width22.5 mm
Height165 mm
Depth114 mm

Material specifications

Flammability rating according to UL 94V0 (Housing)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-5 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m

ATEX

Identification II (2) G [Ex e] [Ex d] [Ex px]
Identification II (2) D [Ex t] [Ex p]
CertificatePTB 07 ATEX 3145

UL approval

CertificateNLDX.E228652
CertificateNRNT.E172140

Safety Integrity Level (SIL, IEC 61508)

Identification≤ 3
NoteSafe shutdown
Identification2
NoteMotor protection

Performance Level (ISO 13849)

Identificatione
NoteSafe shutdown

Category (ISO 13849)

Identification≤ 3
NoteSafe shutdown

UL data

SCCR100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
SCCR5 kA (480 V AC (fuse: 20 A RK5 (standard fault)))
FLA6.5 A (480 V AC)
Group installation20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
Group installation30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Category codeNLDX / NRNT

Standards/regulations

Standards/regulationsIEC 60947-1
Standards/regulationsEN 60947-4-2
Standards/regulationsIEC 61508
Standards/regulationsISO 13849

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsalignable, for spacing see derating
Mounting Positionvertical (horizontal DIN rail, motor output below)
Accessories

Why Proax for Phoenix Contact 2903118?

Proax is an authorized distributor of Phoenix Contact 2903118 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability