Official Distributor
SKU
MPN
UCT-WMT (12X4) RD
Weight
0.011 kg
UCT-WMT (12X4) RD - Conductor marker
- The UCT-WMT ... UniCard marking range includes markers for wire marking with marking sleeves from the PATG (HF) ... /PATO ... systems
- The markers, which are supplied in uniform sheets, can be marked quickly, easily, and precisely using the card printers
- The sheets provide additional space for project information and function text that can be helpful during further assembly
- The multi-section marking strips are easy to fit and can be easily separated if required
- Marking service: Phoenix Contact can custom-mark all UniCard markers according to your specifications
Technical Specifications
Marking
Number of individual labels | 50 |
Number of individual labels per row | 10 |
Identification technology | Thermal transfer for sheets and cards |
Dimensions
Width | 12 mm |
Length | 4 mm |
Material specifications
RoHS Compliant | yes |
Color | red |
Material | PC |
Flammability rating according to UL 94 | V0 |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
Components | free from silicone and halogen |
Cable/line
External Cable Diameter | 0.6 mm ... 10 mm |
Test for substances that would hinder coating with paint or varnish
Result | Test passed |
UV resistance
Specification | ISO 4892-2:2013-03 (following) |
Result | Test passed |
Test duration | 96 h |
Wipe resistance of inscriptions
Specification | DIN EN 61010-1 (VDE 0411-1):2011-07 |
Specification | DIN EN 62208 (VDE 0660-511):2012-06 (in parts) |
Isopropyl [CAS No. 67-63-0] | Test passed |
n-Hexane [CAS No. 110-54-3] | Test passed |
Water + Petroleum ether [CAS No. 64742-82-1] | Test passed |
Testing in a condensation changing climate in the presence of sulfur dioxide
Specification | DIN 50018:2013-05 |
Result | Test passed |
Climate level | AHT 1.0 S |
Cycles | 2 |
Salt spray test
Specification | DIN EN 60068-2-11:2000-02 |
Result | Test passed |
Ambient conditions
Ambient Temperature (Operation) | -40 °C ... 120 °C |
Recommended storage conditions | 23 °C/50 % relative humidity. Storage in a dry and dark place in the original packaging is recommended. |
Recommended ambient temperature (storage/transport) | 23 °C |
Recommended humidity (storage/transport) | 50 % |
Standards and Regulations
Wipe resistance | DIN EN 61010-1 (VDE 0411-1) |
Mounting
Mounting Type | insert |
Accessories
Why Proax for Phoenix Contact 0801440?
Proax is an authorized distributor of Phoenix Contact 0801440 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 10 |
Recommended
- Repère pour conducteur, Planche, orange, vierge, repérable avec : TOPMARK NEO, LASER TOPMARK, BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, type de montage: insertion, plage de diamètre de câble: 0,6 ... 10 mm, Nombre d'étiquettes: 50, hauteur du champ de texte: 4 mm, largeur du champ de texte: 12 mm