Surge protection device - TT-EX(I)-M-24DC
Terminal block with two-stage surge protection for a floating Ex-i signal circuit, disconnect knife on both signal paths, separate PE connection, nominal voltage: 24 V DC
- Versions with and without disconnect knife
- To terminate a row of TERMITRAB TT... devices, covers are available in the corresponding colors
- Other voltage levels available on request
- Multi-stage modular terminal blocks with screw connection technology
- Protection of a floating double wire in intrinsically safe circuits
- Use in Ex protection zones 1 and 2
- Conductors can be led up to Ex protection zone 0
- Disconnection of signal circuits by disconnect knife
Technical Specifications
Dimensions
| Height | 94.8 mm |
| Width | 6.2 mm |
| Depth | 69.1 mm |
Ambient conditions
| Ambient Temperature (Operation) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
| Degree of Protection | IP20 (with end cover) |
General
| Housing Material | PA 6.6 |
| Flammability rating according to UL 94 | V-0 |
| Color | sky blue RAL 5015 |
| Mounting Type | DIN rail: 35 mm |
| Type | Double-level terminal block with PE foot – separate PE connection |
| Number of Positions | 2 |
| Direction of action | Line-Line & Line-Earth Ground |
Protective circuit
| IEC test classification | C1 |
| IEC test classification | C2 |
| IEC test classification | C3 |
| IEC test classification | D1 |
| Nominal voltage UN | 24 V DC |
| Maximum continuous voltage UC | 30 V DC |
| Maximum continuous voltage UC | 21 V AC |
| Rated current | 250 mA (40 °C) |
| Operating effective current IC at UC | ≤ 5 µA |
| Residual current IPE | ≤ 1 µA |
| Nominal discharge current In (8/20) µs (line-line) | 5 kA |
| Nominal discharge current In (8/20) µs (line-earth) | 5 kA |
| Pulse discharge current Iimp (10/350) µs (line-earth) | 500 A |
| Total discharge current Itotal (8/20) µs | 10 kA |
| Nominal pulse current Ian (10/1000) µs (line-line) | 100 A |
| Nominal pulse current Ian (10/1000) µs (line-earth) | 100 A |
| Output voltage limitation at 1 kV/µs (line-line) spike | ≤ 44 V |
| Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 1.5 kV |
| Output voltage limitation at 1 kV/µs (line-line) static | ≤ 44 V |
| Output voltage limitation at 1 kV/µs (line-earth) static | ≤ 1.5 kV |
| Residual voltage at In (line-line) | ≤ 40 V |
| Residual voltage at In (line-earth) | ≤ 110 V |
| Voltage protection level Up (line-line) | ≤ 70 V (C2 - 10 kV / 5 kA) |
| Voltage protection level Up (line-earth) | ≤ 1.5 kV (C2 - 10 kV / 5 kA) |
| Response time tA (line-line) | ≤ 1 ns |
| Response time tA (line-earth) | ≤ 100 ns |
| Input attenuation aE, sym. | typ. 1 dB (≤ 1 MHz / 50 Ω) |
| Input attenuation aE, sym. | typ. 0.3 dB (≤ 200 kHz / 150 Ω) |
| Cut-off frequency fg (3 dB), sym. in 50 Ω system | typ. 6 MHz |
| Cut-off frequency fg (3 dB), sym. in 150 Ω system | typ. 2 MHz |
| Resistance per path | 4.7 Ω ±20 % |
| Surge protection fault message | none |
| Max. required back-up fuse | 250 mA |
| Impulse durability (line-line) | C2 - 10 kV / 5 kA |
| Impulse durability (line-earth) | C2 - 10 kV / 5 kA |
| Impulse durability (line-earth) | D1 - 500 A |
Connection data
| Connection Method | Screw connection |
| Connection method IN | Screw terminal blocks |
| Connection method OUT | Screw terminal blocks |
| Screw thread | M3 |
| Tightening torque | 0.6 Nm |
| Stripping length | 8 mm |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section AWG | 24 ... 14 |
Standards and Regulations
| Standards/specifications | EN 61643-21 2001 + A1:2009 + A2:2013 |
| Standards/specifications | EN 60079-0 2012 |
| Standards/specifications | EN 60079-11 2012 |
| Standards/specifications | EN 60079-26 2007 |
| Standards/specifications | IEC 60079-0 2011 |
| Standards/specifications | IEC 60079-11 2011 |
| Standards/specifications | IEC 60079-26 2006 |
Ex data
| Maximum inner capacitance Ci | 2 nF |
| Max. internal inductance Li | 1 µH |
| Maximum inner time factor (Ri/Li) | 0.1 µs |
| Max. input current Ii | 250 mA (TA < 40 °C) |
| Max. input voltage Ui | 30 V DC |
| max. input power Pi | 0.75 W |
| Ambient Temperature (Operation) | -40 °C ... 40 °C (T6 / 85 °C) |
| Ambient Temperature (Operation) | -40 °C ... 50 °C (T5 / T 100 °C) |
| Ambient Temperature (Operation) | -40 °C ... 80 °C (T4 / 135 °C) |
Conformity / approvals
| ATEX | ??? II 1G Ex ia IIC T4...T6 Ga |
| ATEX | ??? II 1D Ex ia IIIC T135°C...T85°C Da |
| IECEx | Ex ia IIC T4...T6 Ga |
| IECEx | Ex ia IIIC T135 °C...T85 °C Da |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
| China RoHS | Environmentally Friendly Use Period = 50 years |
| China RoHS | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Accessories
Why Proax for Phoenix Contact 2803865?
Proax is an authorized distributor of Phoenix Contact 2803865 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 14 |
Recommended