Official Distributor
SKU
MPN
IBS PCI 104 SC-T
Weight
0.117 kg
Termination board IBS PCI 104 SC-T
Termination board in PCI-104 format, connects an INTERBUS network to a control system with PCI-104 interface, without electrical isolation
- External 24 V DC power supply
- Direct integration into OPC-based visualization systems via OPC server
- Installation of several cards in a PC with monitoring of multiple INTERBUS lines
- Compatible driver
- Access to INTERBUS system data and controller data via visualization stations
- INTERBUS parameter channel (PCP) supported
- Parameterization and diagnostics with Diag+
- Access to high-level language applications via HFI
Technical Specifications
Dimensions
Width | 90 mm |
Height | 96 mm |
Width | 90 mm |
Height | 96 mm |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | 0 °C ... 55 °C (acc. to EN 60204-1) |
Ambient temperature (storage/transport) | -25 °C ... 75 °C (acc. to EN 60204-1) |
Permissible humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Air pressure (operation) | 860 hPa ... 1080 hPa (up to 2000 m above sea level) |
Air pressure (storage/transport) | 660 hPa ... 1080 hPa (up to 3000 m above sea level) |
Shock | 2g, criterion A acc. to IEC 60068-2-6 |
Control system
Control system | IBM-compatible PCs with PCI-104 slot |
Diagnostics tool | DIAG+ from version 1.0x |
Configuration tool | CMD from version 4.62 |
Operating system | Windows NT |
Operating system | Windows 2000 |
Operating system | Windows XP |
Operating system | Venturcom RTX 5.x |
Operating system | Further types on request |
Software interfaces
Driver | Windows NT |
Driver | Windows 2000 |
Driver | Windows XP |
Driver | Venturcom RTX 5.x |
Driver | Further types on request |
Application interface | HFI |
Application interface | OPC |
Application interface | DDI |
Software requirements
Configuration tool | CMD from version 4.62 |
Diagnostics tool | DIAG+ from version 1.0x |
Power supply
Power supply connection | Via PCI-104 bus |
Typical current consumption | 0.7 A |
Supply Voltage | 5 V DC |
Supply Voltage Range | ± 5 % (including ripple) |
Power dissipation | max. 3.5 W |
General
Weight | 83.93 g |
Format | PCI-104 |
Data interfaces
Interface | INTERBUS remote bus |
Number | 1 |
Connection Method | 10-pos. DIL pin strip |
Transmission Speed | 500 kbps / 2 Mbps (can be switched) |
Interface | Parameterization/operation/diagnostics |
Number | 1 |
Connection Method | 10-pos. DIL pin strip |
Transmission Speed | 500 kbps / 2 Mbps500 kbps 2 Mbps (can be switched) |
Interface | Host system |
Connection Method | PCI-104 bus, 32 bits, 33 MHz, 5 V |
Interrupts | 1 IRQ, PnP |
Fieldbus function
Amount of Process Data | max. 8192 Bit (INTERBUS) |
Number of supported devices | max. 512 (of which 254 are remote bus devices/bus segments) |
Number of devices with parameter channel | max. 126 |
Standards and Regulations
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Interference emission | Noise emission test as per EN 61000-6-4 Class A |
Immunity to surge | Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, Signal/data lines: 1 kV |
Immunity to burst | Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, Signal/data lines: 2 kV |
Immunity to EF | Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m |
Immunity to ESD | Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge |
Immunity to conducted interference | Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V |
Connection in acc. with standard | CUL |
Shock | 2g, criterion A acc. to IEC 60068-2-6 |
Environmental Product Compliance
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab “Downloads |
Accessories
Why Proax for Phoenix Contact 2737494?
Proax is an authorized distributor of Phoenix Contact 2737494 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended