By Phoenix Contact

SKU
MPN
FK-MC 0,5/12-ST-2,5
Weight
0.007 kg
Series FK-MC

FK-MC 0,5/12-ST-2,5 - PCB connector

PCB connector, nominal cross section: 0.5 mm2, color: green, nominal current: 4 A, rated voltage (III/2): 160 V, contact surface: Tin, contact connection type: Socket, number of potentials: 12, number of rows: 1, number of positions: 12, number of connections: 12, product range: FK-MC 0,5/..-ST, pitch: 2.5 mm, connection method: Push-in spring connection, conductor/PCB connection direction: 0 °, plug-in system: COMBICON FK-MC 0,5, locking: without, mounting: without, type of packaging: packed in cardboard

  • Time saving push-in connection, tools not required
  • Defined contact force ensures that contact remains stable over the long term
  • Intuitive operation due to color-coded actuating push button
  • Operation and conductor connection from one direction enable integration into front of device
  • Quick and convenient testing using integrated test option
Technical Specifications

Product properties

Product familyFK-MC 0,5/..-ST
Product lineCOMBICON Connectors XS
TypeStandard
Number of Positions12
Pitch2.5 mm
Number of Connections12
Number of rows1
Number of potentials12
Mounting flangewithout

Electrical properties

Nominal current IN4 A
Nominal voltage UN160 V
Degree of pollution3
Contact resistance2 mΩ
Rated voltage (III/3)100 V
Rated surge voltage (III/3)1.5 kV
Rated voltage (III/2)160 V
Rated surge voltage (III/2)2.5 kV
Rated voltage (II/2)320 V
Rated surge voltage (II/2)2.5 kV

Connection technology

TypeStandard
Connector systemCOMBICON FK-MC 0,5
Nominal cross section0.5 mm²
Contact connection typeSocket

Interlock

Locking Typewithout
Mounting flangewithout

Conductor connection

Connection MethodPush-in spring connection
Conductor/PCB connection direction0 °
Conductor cross section rigid0.14 mm² ... 0.5 mm²
Conductor cross section flexible0.14 mm² ... 0.5 mm²
Conductor cross section AWG26 ... 20
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 0.5 mm²
Cylindrical gauge a x b / diameter- / 1.4 mm
Stripping length8 mm

Specifications for ferrules without insulating collar

recommended crimping tool1212034 CRIMPFOX 6
ferrules without insulating collar, according to DIN 46228‑1Cross section: 0.25 mm²; Length: 7 mm ... 8 mm
ferrules without insulating collar, according to DIN 46228‑1Cross section: 0.34 mm²; Length: 7 mm ... 8 mm
ferrules without insulating collar, according to DIN 46228‑1Cross section: 0.5 mm²; Length: 8 mm

Material data - contact

NoteWEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
Contact MaterialCu alloy
Surface characteristicshot-dip tin-plated
Metal surface terminal point (top layer)Tin (4 - 8 µm Sn)
Metal surface contact area (top layer)Tin (4 - 8 µm Sn)

Material data - housing

Color (Housing)green (6021)
Insulating materialPA
Insulating material groupI
CTI according to IEC 60112600
Flammability rating according to UL 94V0
Glow wire flammability index GWFI according to EN 60695-2-12850
Glow wire ignition temperature GWIT according to EN 60695-2-13775
Temperature for the ball pressure test according to EN 60695-10-2125 °C

Material data – actuating element

Color (Actuating element)orange (2003)
Insulating materialPBT
Insulating material groupI
CTI according to IEC 60112600
Flammability rating according to UL 94V0

Dimensions

Pitch2.5 mm
Width [w]30.6 mm
Height [h]11.75 mm
Length [l]19.05 mm

Notes

Notes on operationIn accordance with IEC 61984, COMBICON connectors have no switching power (COC). During designated use, they must not be plugged in or disconnected when carrying voltage or under load.

Conductor connection

SpecificationIEC 60999-1:1999-11
ResultTest passed

Test for conductor damage and slackening

SpecificationIEC 60999-1:1999-11
ResultTest passed

Repeated connection and disconnection

SpecificationIEC 60999-1:1999-11
ResultTest passed

Pull-out test

SpecificationIEC 60999-1:1999-11
Conductor cross section/conductor type/tractive force setpoint/actual value0.2 mm² / solid / > 10 N
Conductor cross section/conductor type/tractive force setpoint/actual value0.2 mm² / flexible / > 10 N
Conductor cross section/conductor type/tractive force setpoint/actual value0.5 mm² / solid / > 20 N
Conductor cross section/conductor type/tractive force setpoint/actual value0.5 mm² / flexible / > 20 N

Insertion and withdrawal forces

ResultTest passed
No. of cycles25
Insertion strength per pos. approx.8 N
Withdraw strength per pos. approx.6 N

Resistance of inscriptions

SpecificationIEC 60068-2-70:1995-12
ResultTest passed

Polarization and coding

SpecificationIEC 60512-13-5:2006-02
ResultTest passed

Visual inspection

SpecificationIEC 60512-1-1:2002-02
ResultTest passed

Dimension check

SpecificationIEC 60512-1-2:2002-02
ResultTest passed

Vibration test

SpecificationIEC 60068-2-6:2007-12
Frequency10 - 150 - 10 Hz
Sweep speed1 octave/min
Amplitude0.35 mm (10 Hz ... 60.1 Hz)
Acceleration5g (60.1 Hz ... 150 Hz)
Test duration per axis2.5 h

Durability test

SpecificationIEC 60512-9-1:2010-03
Impulse withstand voltage at sea level2.95 kV
Contact resistance R12 mΩ
Contact resistance R22.2 mΩ
Insertion/withdrawal cycles25
Insulation resistance, neighboring positions> 5 MΩ

Climatic test

SpecificationISO 6988:1985-02
Corrosive stress0.2 dm3 SO2 on 300 dm3/40 °C/1 cycle
Thermal stress100 °C/168  h
Power-frequency withstand voltage1.39 kV

Ambient conditions

Ambient Temperature (Operation)-40 °C ... 100 °C (dependent on the derating curve)
Ambient temperature (storage/transport)-40 °C ... 70 °C
Relative humidity (storage/transport)30 % ... 70 %
Ambient temperature (assembly)-5 °C ... 100 °C

Thermal test | Test group C

SpecificationIEC 60512-5-1:2002-02
Tested number of positions12

Insulation resistance

SpecificationIEC 60512-3-1:2002-02
Insulation resistance, neighboring positions> 5 MΩ

Temperature cycles

SpecificationIEC 60999-1:1999-11
ResultTest passed

Air clearances and creepage distances |

SpecificationIEC 60664-1:1992-10 + A1:2000-02 + A2:2002-05
Insulating material groupI
Comparative tracking index (IEC 60112)CTI 600
Rated insulation voltage (III/3)100 V
Rated surge voltage (III/3)1.5 kV
minimum clearance value - non-homogenous field (III/3)0.8 mm
minimum creepage distance (III/3)1.8 mm
Rated insulation voltage (III/2)160 V
Rated surge voltage (III/2)2.5 kV
minimum clearance value - non-homogenous field (III/2)1.5 mm
minimum creepage distance (III/2)1.5 mm
Rated insulation voltage (II/2)320 V
Rated surge voltage (II/2)2.5 kV
minimum clearance value - non-homogenous field (II/2)1.5 mm
minimum creepage distance (II/2)1.6 mm

Packaging specifications

Type of packagingpacked in cardboard
Accessories

Why Proax for Phoenix Contact 1881422?

Proax is an authorized distributor of Phoenix Contact 1881422 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size50
Recommended
Sold in quantities of 50

Available for order

Phoenix Contact Availability