The NF22E-13 is a 690 V IEC or 600 UL 4-pole contactor relay with screw terminals, used for switching auxiliary and control circuits. Thanks to the AF technology, the contactor relay has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. NF contactor relays have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. These contactor relays include mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and are side-marked with the "Mechanically Linked" symbol.
Technical Specifications

Supplier Information - AETAD009

Country or Territory of OriginIndia
Lead Time0 day
Made to OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesAETAD009EXPU

Supplier Information - AUABB004

Country or Territory of OriginAustralia
Lead Time42 day
Made to OrderNo
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesAUABB004EXPU
Warranty ReturnProduct under warranty must be returned

Supplier Information - BRABB008

Country or Territory of OriginIndia
Lead Time0 day
Made to OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesBRABB008EXPU

Supplier Information - CHABB001

Country or Territory of OriginFrance
Lead Time76 day
Made to OrderNo
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesCHABB001EXPU
Warranty ReturnProduct under warranty must be returned

Supplier Information - CHSEC006

Country or Territory of OriginIndia
Lead Time0 day
Made to OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesCHSEC006EXPU

Supplier Information - DEUTS002

Country or Territory of OriginFrance
Lead Time14 day
Made to OrderNo
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesDEUTS002EXPU
Warranty ReturnProduct under warranty must be returned

Supplier Information - INABB003

Country or Territory of OriginIndia
Made to OrderNo
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABB003EXPU
Warranty ReturnProduct under warranty must be returned

Supplier Information - INABB010

Country or Territory of OriginIndia
Made to OrderNo
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABB010EXPU
Warranty ReturnProduct under warranty must be returned

Dimensions

Product Net Width45 mm
Product Net Depth / Length77 mm
Product Net Height86 mm
Product Net Weight0.27 kg

Technical

Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Number of Poles4P
StandardsIEC/EN 60947-1, IEC/EN 60947-5-1, UL 60335-2-40 LZGH2 A2L, UL 508, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 14-13
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Rated Frequency (f)Control Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A
Rated Operational Current AC-15 (Ie)(690 V) 2 A
Rated Operational Current AC-15 (Ie)(24 / 127 V) 6 A
Rated Operational Current AC-15 (Ie)(220 / 240 V) 4 A
Rated Operational Current AC-15 (Ie)(400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
Rated Operational Current DC-13 (Ie)(48 V) 2.8 A / 134 W
Rated Operational Current DC-13 (Ie)(72 V) 1 A / 72 W
Rated Operational Current DC-13 (Ie)(110 V) 0.55 A / 60 W
Rated Operational Current DC-13 (Ie)(125 V) 0.55 A / 69 W
Rated Operational Current DC-13 (Ie)(220 V) 0.27 A / 60 W
Rated Operational Current DC-13 (Ie)(250 V) 0.27 A / 68 W
Rated Operational Current DC-13 (Ie)(400 V) 0.15 A / 60 W
Rated Operational Current DC-13 (Ie)(500 V) 0.13 A / 65 W
Rated Operational Current DC-13 (Ie)(600 V) 0.1 A / 60 W
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 100 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 690 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour
Maximum Electrical Switching Frequency(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency6000 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V
Rated Control Circuit Voltage (Uc)60 Hz 100 ... 250 V
Rated Control Circuit Voltage (Uc)DC Operation 100 ... 250 V
Power Lossat 6 A per Pole 0.1 W
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms
Operate TimeBetween Coil De-energization and NO Contact Opening 11 ... 95 ms
Operate TimeBetween Coil Energization and NC Contact Opening 38 ... 90 ms
Operate TimeBetween Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 Screws Placed Diagonally
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Auxiliary CircuitRigid Solid 1/2x 1 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitRigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Control CircuitRigid Solid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitRigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm
Wire Stripping LengthControl Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Tightening torqueAuxiliary Circuit 1.2 N·m
Tightening torqueControl Circuit 1.2 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor Relay

Technical UL/CSA

Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Connecting Capacity Auxiliary Circuit UL/CSARigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb
Tightening Torque UL/CSAControl Circuit 11 in·lb

ABB EcoSolutions

End Of Life Disassembling Instructions1SBC101080M6801
Environmental Product Declaration - EPD1SBD250584E3000
Environmental Product Declaration - EPD2TFP200035A1001
Sustainable Material Content in Packaging (wt. %)Recycled Cardboard - 86 %
Sustainable Material Content in Product (wt. %)Recycled Metal - 28 %

Why Proax for ABB NF22E-13?

Proax is an authorized distributor of ABB NF22E-13 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesNF22E13
Pack Size1
Recommended

CAD$60.15

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability