Series PWO
PWO 16-F - Panel feed-through terminal block
Mounting flange, for mounting directly on the wall
- Time saving push-in connection, tools not required
- Defined contact force ensures that contact remains stable over the long term
- Tool-free snap-in principle enables easy mounting on the device panel
- Automatic panel thickness compensation enables universal use
- Reliable seal even with low-viscosity molding compounds
Technical Specifications
Product properties
| Product family | BF BEFESTIGUNGSFLANSCHE |
| Number of Positions | 0 |
| Pitch | 0 mm |
Electrical properties
| Nominal current IN | 76 A |
| Nominal voltage UN | 1000 V |
| Degree of pollution | 3 |
| Rated voltage (III/3) | 1000 V |
| Rated surge voltage (III/3) | 8 kV |
| Rated voltage (III/2) | 1000 V |
| Rated surge voltage (III/2) | 8 kV |
| Rated voltage (II/2) | 1000 V |
| Rated surge voltage (II/2) | 6 kV |
Connection technology
| Connector system | UW 16 / PW 16 |
| Nominal cross section | 16 mm² |
Conductor connection exterior
| Connection Method | Push-in spring connection |
| Connection direction of the conductor to plug-in direction | 45 ° |
| Conductor cross section rigid | 1.5 mm² ... 16 mm² |
| Conductor cross section flexible | 1.5 mm² ... 16 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve | 1.5 mm² ... 16 mm² |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 1.5 mm² ... 16 mm² |
| 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 1.5 mm² ... 4 mm² |
| Stripping length | 18 mm |
Conductor connection interior
| Connection Method | Cable lug connection |
| Connection direction of the conductor to plug-in direction | 0 ° |
Attachment to feed-through panel
| Tightening torque | 1 Nm (Mounting screw torque) |
| Screw | M4 |
Material data - contact
| Note | WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 |
| Contact Material | Cu alloy |
| Surface characteristics | tin-plated |
Material data - housing
| Color (Housing) | gray (7042) |
| Insulating material | PA |
| Insulating material group | I |
| CTI according to IEC 60112 | 600 |
| Flammability rating according to UL 94 | V0 |
| Glow wire flammability index GWFI according to EN 60695-2-12 | 850 |
| Glow wire ignition temperature GWIT according to EN 60695-2-13 | 775 |
| Temperature for the ball pressure test according to EN 60695-10-2 | 125 °C |
Safety note
| Safety note | • Only electrically qualified personnel may install and operate the product.To recognize and prevent danger, the qualified personnel must be familiar with the basics of electrical engineering. |
| Safety note | • Observe the technical data provided here and refer to the documents listed under “Downloads”. The download area contains important information, such as installation notes, technical drawings, and 3D data. |
| Safety note | • To maintain the nominal voltage, align the cable lugs straight and centered, and cast the terminals on the inside. |
| Safety note | • The cable entry funnel is not safe to touch. Never connect or disconnect the terminal when it is energized. Take appropriate steps to ensure touch protection. |
Dimensions
| Pitch | 0 mm |
Test for conductor damage and slackening
| Specification | IEC 60947-7-1:2009-04 |
| Result | Test passed |
Pull-out test
| Specification | IEC 60947-7-1:2009-04 |
| Conductor cross section/conductor type/tractive force setpoint/actual value | 1.5 mm² / solid / > 40 N |
| Conductor cross section/conductor type/tractive force setpoint/actual value | 1.5 mm² / flexible / > 40 N |
| Conductor cross section/conductor type/tractive force setpoint/actual value | 16 mm² / solid / > 100 N |
| Conductor cross section/conductor type/tractive force setpoint/actual value | 16 mm² / flexible / > 100 N |
Temperature-rise test
| Specification | IEC 60947-7-1:2009-04 (following) |
| Requirement temperature-rise test | Increase in temperature ≤ 45 K |
Short-time withstand current
| Specification | IEC 60947-7-1:2009-04 |
Air clearances and creepage distances | 1. Insulation coordination
| Application | Internal part molded |
| Application | Control cabinet panel 1 mm ... 4 mm |
| Specification | IEC 60947-1:2007-06 + A1:2010-12 |
| Insulating material group | I |
| Comparative tracking index (IEC 60112) | CTI 600 |
| Rated insulation voltage (III/3) | 1000 V |
| Rated surge voltage (III/3) | 8 kV |
| minimum clearance value - non-homogenous field (III/3) | 8 mm |
| minimum creepage distance (III/3) | 12.5 mm |
| Rated insulation voltage (III/2) | 1000 V |
| Rated surge voltage (III/2) | 8 kV |
| minimum clearance value - non-homogenous field (III/2) | 8 mm |
| minimum creepage distance (III/2) | 8 mm |
| Rated insulation voltage (II/2) | 1000 V |
| Rated surge voltage (II/2) | 6 kV |
| minimum clearance value - non-homogenous field (II/2) | 5.5 mm |
| minimum creepage distance (II/2) | 5.5 mm |
Air clearances and creepage distances | 2. Insulation coordination
| Application | Internal part molded |
| Application | Control cabinet panel 5 mm ... 6 mm |
| Specification | IEC 60947-1:2007-06 + A1:2010-12 |
| Insulating material group | I |
| Comparative tracking index (IEC 60112) | CTI 600 |
| Rated insulation voltage (III/3) | 800 V |
| Rated surge voltage (III/3) | 8 kV |
| minimum clearance value - non-homogenous field (III/3) | 8 mm |
| minimum creepage distance (III/3) | 10 mm |
| Rated insulation voltage (III/2) | 1000 V |
| Rated surge voltage (III/2) | 8 kV |
| minimum clearance value - non-homogenous field (III/2) | 8 mm |
| minimum creepage distance (III/2) | 8 mm |
| Rated insulation voltage (II/2) | 1000 V |
| Rated surge voltage (II/2) | 6 kV |
| minimum clearance value - non-homogenous field (II/2) | 5.5 mm |
| minimum creepage distance (II/2) | 5.5 mm |
Air clearances and creepage distances | 3. Insulation coordination
| Application | Internal part not molded |
| Application | DP-PWO 16-3 (width: 3 mm) |
| Specification | IEC 60947-1:2007-06 + A1:2010-12 |
| Insulating material group | I |
| Comparative tracking index (IEC 60112) | CTI 600 |
| Rated insulation voltage (III/3) | 400 V |
| Rated surge voltage (III/3) | 4 kV |
| minimum clearance value - non-homogenous field (III/3) | 3 mm |
| minimum creepage distance (III/3) | 5 mm |
| Rated insulation voltage (III/2) | 500 V |
| Rated surge voltage (III/2) | 4 kV |
| minimum clearance value - non-homogenous field (III/2) | 3 mm |
| minimum creepage distance (III/2) | 3 mm |
| Rated insulation voltage (II/2) | 800 V |
| Rated surge voltage (II/2) | 4 kV |
| minimum clearance value - non-homogenous field (II/2) | 3 mm |
| minimum creepage distance (II/2) | 4 mm |
Air clearances and creepage distances | 4. Insulation coordination
| Application | Internal part not molded |
| Application | DP-PWO 16-6 (width: 6 mm) |
| Specification | IEC 60947-1:2007-06 + A1:2010-12 |
| Insulating material group | I |
| Comparative tracking index (IEC 60112) | CTI 600 |
| Rated insulation voltage (III/3) | 800 V |
| Rated surge voltage (III/3) | 6 kV |
| minimum clearance value - non-homogenous field (III/3) | 5.5 mm |
| minimum creepage distance (III/3) | 10 mm |
| Rated insulation voltage (III/2) | 800 V |
| Rated surge voltage (III/2) | 8 kV |
| minimum clearance value - non-homogenous field (III/2) | 8 mm |
| minimum creepage distance (III/2) | 8 mm |
| Rated insulation voltage (II/2) | 1000 V |
| minimum clearance value - non-homogenous field (II/2) | 0 mm |
| minimum creepage distance (II/2) | 5 mm |
Air clearances and creepage distances | 5. Insulation coordination
| Application | Internal part not molded |
| Application | DP-PWO 16-9 (width: 9 mm) |
| Application | Control cabinet panel 1 mm ... 4 mm |
| Specification | IEC 60947-1:2007-06 + A1:2010-12 |
| Insulating material group | I |
| Comparative tracking index (IEC 60112) | CTI 600 |
| Rated insulation voltage (III/3) | 1000 V |
| Rated surge voltage (III/3) | 8 kV |
| minimum clearance value - non-homogenous field (III/3) | 8 mm |
| minimum creepage distance (III/3) | 12.5 mm |
| Rated insulation voltage (III/2) | 1000 V |
| Rated surge voltage (III/2) | 8 kV |
| minimum clearance value - non-homogenous field (III/2) | 8 mm |
| minimum creepage distance (III/2) | 8 mm |
| Rated insulation voltage (II/2) | 1000 V |
| Rated surge voltage (II/2) | 6 kV |
| minimum clearance value - non-homogenous field (II/2) | 5.5 mm |
| minimum creepage distance (II/2) | 5.5 mm |
Air clearances and creepage distances | 6. Insulation coordination
| Application | Internal part not molded |
| Application | DP-PWO 16-9 (width: 9 mm) |
| Application | Control cabinet panel 5 mm ... 6 mm |
| Specification | IEC 60947-1:2007-06 + A1:2010-12 |
| Insulating material group | I |
| Comparative tracking index (IEC 60112) | CTI 600 |
| Rated insulation voltage (III/3) | 800 V |
| Rated surge voltage (III/3) | 8 kV |
| minimum clearance value - non-homogenous field (III/3) | 8 mm |
| minimum creepage distance (III/3) | 10 mm |
| Rated insulation voltage (III/2) | 1000 V |
| Rated surge voltage (III/2) | 8 kV |
| minimum clearance value - non-homogenous field (III/2) | 8 mm |
| minimum creepage distance (III/2) | 8 mm |
| Rated insulation voltage (II/2) | 1000 V |
| Rated surge voltage (II/2) | 6 kV |
| minimum clearance value - non-homogenous field (II/2) | 5.5 mm |
| minimum creepage distance (II/2) | 5.5 mm |
Air clearances and creepage distances | 7. Insulation coordination
| Application | Internal part not molded |
| Specification | IEC 60947-1:2007-06 + A1:2010-12 |
| Insulating material group | I |
| Comparative tracking index (IEC 60112) | CTI 600 |
| minimum clearance value - non-homogenous field (III/3) | 0 mm |
| minimum creepage distance (III/3) | 0 mm |
| minimum clearance value - non-homogenous field (III/2) | 0 mm |
| minimum creepage distance (III/2) | 0 mm |
| minimum clearance value - non-homogenous field (II/2) | 0 mm |
| minimum creepage distance (II/2) | 0 mm |
Vibration test
| Specification | IEC 60068-2-6:2007-12 |
| Frequency | 10 - 150 - 10 Hz |
| Sweep speed | 1 octave/min |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Acceleration | 5g (60.1 Hz ... 150 Hz) |
| Test duration per axis | 2.5 h |
Glow-wire test
| Specification | IEC 60695-2-11:2000-10 |
| Temperature | 960 °C |
| Time of exposure | 30 s |
Ambient conditions
| Ambient Temperature (Operation) | -40 °C ... 100 °C (Depending on the current carrying capacity/derating curve) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Relative humidity (storage/transport) | 30 % ... 70 % |
| Ambient temperature (assembly) | -5 °C ... 100 °C |
Packaging specifications
| Type of packaging | packed in cardboard |
Why Proax for Phoenix Contact 1705659?
Proax is an authorized distributor of Phoenix Contact 1705659 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 25 |
Recommended