MPN
1SAZ741201R1038
Weight
0.13 kg
The TF42-B thermal overload relays are economic electromechanical protection devices for the main circuit, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10. The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a change of the contacts switching position (95-96 / 97-98). – Manual or automatic reset selectable – Phase loss sensitive acc. to IEC/EN 60947-4-1 – TEST and STOP function – Trip indication on the front – Temperature compensation – Suitable for three- and single-phase applications – designed in accordance to the applicable parts of IEC 60077 standard – shocks and vibration withstand conforming to IEC 61373 (category 1, class B) – usable according to European fire and smoke safety standard EN 45545-2
Technical Specifications

Dimensions

Product Net Width45 mm
Product Net Height88.3 mm
Product Net Depth / Length70.5 mm
Product Net Weight0.13 kg

Technical

Setting range4.2 ... 5.7 A
Rated Operational VoltageAuxiliary Circuit 600 V AC/DC
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (Ie)5.7 A
Rated Frequency (f)Auxiliary Circuit 50 Hz
Rated Frequency (f)Auxiliary Circuit 60 Hz
Rated Frequency (f)Auxiliary Circuit DC
Rated Frequency (f)Main Circuit 50 Hz
Rated Frequency (f)Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Number of Poles3
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number of Protected Poles3
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit NC 6 A
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit NO 4 A
Conventional Free-air Thermal Current (Ith)Main Circuit 0 A
Rated Operational Current AC-15 (Ie)(120 V) NC 3 A
Rated Operational Current AC-15 (Ie)(120 V) NO 0.75 A
Rated Operational Current AC-15 (Ie)(240 V) NC 3 A
Rated Operational Current AC-15 (Ie)(240 V) NO 0.75 A
Rated Operational Current AC-15 (Ie)(400 V) NC 0.75 A
Rated Operational Current AC-15 (Ie)(400 V) NO 0.75 A
Rated Operational Current AC-15 (Ie)(500 V) NC 0.75 A
Rated Operational Current AC-15 (Ie)(500 V) NO 0.75 A
Rated Operational Current DC-13 (Ie)(125 V) NC 0.55 A
Rated Operational Current DC-13 (Ie)(125 V) NO 0.55 A
Rated Operational Current DC-13 (Ie)(24 V) NC 1.25 A
Rated Operational Current DC-13 (Ie)(24 V) NO 1.25 A
Rated Operational Current DC-13 (Ie)(250 V) NC 0.27 A
Rated Operational Current DC-13 (Ie)(250 V) NO 0.27 A
Rated Operational Current DC-13 (Ie)(500 V) NC 0.15 A
Rated Operational Current DC-13 (Ie)(500 V) NO 0.15 A
Rated Operational Current DC-13 (Ie)(60 V) NC 0.55 A
Rated Operational Current DC-13 (Ie)(60 V) NO 0.55 A
Degree of ProtectionIP20
Pollution degree3
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Connecting Capacity Auxiliary CircuitFlexible 1/2x 0.75 ... 1 mm²
Connecting Capacity Auxiliary CircuitFlexible 1/2x 1 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitRigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 4 mm²
Connecting Capacity Main CircuitFlexible with Insulated Ferrule 1/2x 0.75 ... 4 mm²
Connecting Capacity Main CircuitFlexible 1/2x 0.75 ... 4 mm²
Connecting Capacity Main CircuitRigid 1/2x 0.75 ... 4 mm²
Tightening torqueAuxiliary Circuit 1 ... 1.2 N·m
Tightening torqueMain Circuit 2.5 ... 2.7 N·m
Wire Stripping LengthAuxiliary Circuit 9 mm
Wire Stripping LengthMain Circuit 12 mm
Recommended Screw DriverMain Circuit Pozidriv 2
Power Lossat Rated Operating Conditions per Pole 1.1 ... 2.0 W
Suitable forAF09ZB
Suitable forAF09B
Suitable forAF12ZB
Suitable forAF12B
Suitable forAF16ZB
Suitable forAF16B
Suitable forAF26ZB
Suitable forAF26B
Suitable forAF30ZB
Suitable forAF30B
Suitable forAF38ZB
Suitable forAF38B
StandardsIEC/EN 60947-1
StandardsIEC/EN 60947-4-1
StandardsIEC/EN 60947-5-1
StandardsUL 60947-1
StandardsUL 60947-4-1
StandardsIEC 60335-2-40 A2L

Technical UL/CSA

Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Contact Rating UL/CSA(NC:) B600
Contact Rating UL/CSA(NC:) Q600
Contact Rating UL/CSA(NO:) Q600
Contact Rating UL/CSA(NO:) D300
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 18-10 AWG
Connecting Capacity Main Circuit UL/CSAStranded 1/2x 18-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSAFlexible 1/2x 18-12 AWG
Connecting Capacity Auxiliary Circuit UL/CSAStranded 1/2x 18-12 AWG
Tightening Torque UL/CSAAuxiliary Circuit 9 ... 11 in·lb
Tightening Torque UL/CSAMain Circuit 13 ... 22 in·lb

Why Proax for ABB TF42-5.7B?

Proax is an authorized distributor of ABB TF42-5.7B and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesTF4257B
Pack Size1