Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
HC-B 6-I-UT-M
Weight
0.048 kg
Series HC-B

HC-B 6-I-UT-M - Contact insert

Contact insert, number of positions: 6+PE, size: B6, number of connections per position: 1, Pin, Screw connection, 500 V, 16 A, 0.5 mm2 ... 2.5 mm2, application: Power

  • For fast coding with plastic profile
  • For test pin 2 mm
Technical Specifications

Notes

Generalfor flexible conductors with or without ferrules
GeneralConnectors may be operated only when there is no load/voltage.

Mounting

Assembly instructionsTo ensure correct use, installation in housing with IP54 protection or better is required

Product properties

SeriesHC-B
ApplicationPower
TypeB6
Number of Positions6
Connection profile6+PE
Contact numbering1 - 6
Number of connections per position1
Contact material typeturned
Screwdriver blade0.5 x 3.5 mm

Insulation characteristics

Overvoltage categoryIII
Degree of pollution3

Dimensions

Width34 mm
Height32 mm
Length50.5 mm
Drill hole distance, horizontal44 mm
Drill hole distance, vertical27 mm

Mechanical characteristics

Contact diameter2.5 mm

Connection technology

Connection technologyScrew connection
Number of connections per position1
Connection in acc. with standardIEC / EN

Conductor connection

Conductor Cross Section0.5 mm² ... 2.5 mm²
Connection cross section AWG20 ... 14
Tightening torque0.8 Nm ... 1.2 Nm (PE connection)
Tightening torque0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
Tightening torque0.5 Nm ... 0.8 Nm
Stripping length of the individual wire8 mm

Electrical properties

Rated voltage (III/3)500 V
Rated surge voltage6 kV
Rated current16 A
SCCR5 kA (UL 2237)

Mechanical data

Insertion/withdrawal cycles≥ 500

Material specifications

Flammability rating according to UL 94V0
Contact MaterialCopper alloy
Contact surface materialAg
Contact carrier materialPC
Standards/regulationsPC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Ambient conditions

Ambient Temperature (Operation)-40 °C ... 125 °C (including heating up of contacts)

Standards and Regulations

Constructional and testing regulationsDIN EN 61984
Constructional and testing regulationsDIN EN 60664
Constructional and testing regulationsIEC 60352
TestsDIN EN 61984
TestsDIN EN 60664
TestsIEC 60352

Testing

Standards/regulationsPC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Accessories

Why Proax for Phoenix Contact 1648115?

Proax is an authorized distributor of Phoenix Contact 1648115 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability