Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
SAC-4P- 2,0-960/MINFS VAL
Weight
0.181 kg
Series SAC-4P

SAC-4P- 2,0-960/MINFS VAL - Bus system cable

Bus system cable, FOUNDATION Fieldbus (31.25 kbps), 3-position, PVC, orange RAL 2003, shielded (Plastic-coated aluminum foil with a drain wire), free cable end, on Socket straight 7/8"-16UNF, coding: A, cable length: 2 m

Technical Specifications

Product properties

ApplicationProcess technology
Sensor TypeFOUNDATION Fieldbus
Number of Positions3
No. of cable outlets1
Shieldedyes
CodingA

Insulation characteristics

Overvoltage categoryII
Degree of pollution2

Interfaces

Bus systemFOUNDATION Fieldbus
Signal type/categoryFOUNDATION Fieldbus, 31.25 kbps

Signaling

Status displayNo
Status display presentNo

Electrical properties

Insulation resistance≥ 10 MΩ
Nominal voltage UN300 V
Nominal current IN5.2 A
Transmission mediumCopper

Material specifications

Flammability rating according to UL 94HB
Material of grip bodyTPU
Contact MaterialCuZn
Contact surface materialAu
Contact carrier materialPA 6.6
Material for screw connectionStainless steel

Pin assignment

Contact | Color (signal designation) | Contact (optional)1 (Socket) | BU (DATA-)
Contact | Color (signal designation) | Contact (optional)2 (Socket) | OG (DATA+)
Contact | Color (signal designation) | Contact (optional)3 (Socket) | SR (shield)

Connection 1

Typefree cable end

Connection 2

TypeSocket straight 7/8"-16UNF
Number of Positions3
Coding typeA (Standard)

Cable/line

Cable Length2 m

FOUNDATION Fieldbus orange [960]

Cable weight56.552 kg/km
Number of Positions2
Shieldedyes
Cable TypeFOUNDATION Fieldbus orange [960]
Conductor structure2xAWG18/7 + 1xAWG20/7
Signal speed0.66 c
Conductor structure signal line7x 0.40 mm
AWG Signal Line18
Conductor Cross Section2x 0.75 mm² (Signal line)
Conductor Cross Section1x 0.5 mm² (Drain wire)
Wire diameter incl. insulation2.24 mm ±0.05 mm
External Cable Diameter7.50 mm ±0.25 mm
Outer sheath, materialPVC
External sheath, colororange RAL 2003
Conductor materialTin-plated Cu litz wires
Material wire insulationPO (Signal line)
Single wire, colorblue, orange
Thickness, insulation0.50 mm
Thickness, outer sheath1.00 mm
Twisted pairs2 cores to the pair
Overall twistOne pair with one drain wire and fillers for core
Optical shield covering100 %
Max. conductor resistance≤ 19.35 Ω/km (Signal line)
Max. conductor resistance26 Ω/km (shield)
Cable capacity147 pF/m (at 1 kHz, core/shield)
Cable capacity≤ 3.94 pF/m (capacitance unbalance)
Working capacitance78 nF (at 1 kHz)
Cable impedance100 Ω ±20 % (At 31.25 kHz)
Nominal voltage, cable300 V
Smallest bending radius, fixed installation75 mm
Tensile strength260 N
Shield attenuation3.00 dB/km (at 39 kHz)
Flame resistanceUL 1685 (CSA FT 4)
Flame resistanceUL 1685 (vertical tray)
Flame resistanceUL 1666 (riser)
Special PropertiesUL standards PLTC-ER and ITC
Ambient Temperature (Operation)-40 °C ... 105 °C (cable, fixed installation)

Ambient conditions

Degree of ProtectionIP67
Ambient Temperature (Operation)-40 °C ... 105 °C (Plug / socket)

Why Proax for Phoenix Contact 1429712?

Proax is an authorized distributor of Phoenix Contact 1429712 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!