UC1-TMF 8
Weight
0.007 kg
This product is Not Cancellable/Not Returnable
Series UC1-TMF

UC1-TMF 8 - Marker for terminal blocks

  • The markers, which are supplied in uniform sheets, can be printed onto quickly and easily using the BLUEMARK printing systems
  • The UC1-TMF ... UniCard labeling range includes markers for Weidmüller, Wago, ABB (entrelec), Conta-Clip, and Klemsan terminal blocks
  • The multi-section marking strips are easy to fit and can be easily separated if required
  • The markers support multi-line labeling
  • The sheets provide space for including function texts
  • Marking service: Phoenix Contact can custom-mark all UniCard markers according to your specifications
Technical Specifications

Product properties

Area of applicationWeidmüller, Wago, ABB, CONTA-CLIP, and Klemsan: Terminal blocks
Pitch8 mm
Typeflat

Marking

Number of individual labels64
Number of individual labels per row8
Identification technologyUV LED technology

Dimensions

Width8 mm
Pitch8 mm

Material specifications

RoHS Compliantyes
Colorwhite
MaterialPA
Flammability rating according to UL 94V2
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))120 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2
Componentsfree from silicone and halogen

Test for substances that would hinder coating with paint or varnish

ResultTest passed

UV resistance

SpecificationISO 4892-2:2013-03 (following)
ResultTest passed
Test duration96 h

Wipe resistance of inscriptions

SpecificationDIN EN 61010-1 (VDE 0411-1):2011-07
SpecificationDIN EN 62208 (VDE 0660-511):2012-06 (in parts)
Isopropyl
[CAS No. 67-63-0]
Test passed
n-Hexane
[CAS No. 110-54-3]
Test passed
Water + Petroleum ether
[CAS No. 64742-82-1]
Test passed

Testing in a condensation changing climate in the presence of sulfur dioxide

SpecificationDIN 50018:2013-05
ResultTest passed
Climate levelAHT 1.0 S
Cycles2

Salt spray test

SpecificationDIN EN 60068-2-11:2000-02
ResultTest passed

Ambient conditions

Ambient Temperature (Operation)-40 °C ... 120 °C
Recommended storage conditions23 °C/50 % relative humidity. Storage in a dry and dark place in the original packaging is recommended.
Recommended ambient temperature (storage/transport)23 °C
Recommended humidity (storage/transport)50 %

Standards and Regulations

Wipe resistanceDIN EN 61010-1 (VDE 0411-1)

Mounting

Mounting Typesnapped
Accessories

Why Proax for Phoenix Contact 0821548?

Proax is an authorized distributor of Phoenix Contact 0821548 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size10
Recommended
Sold in quantities of 10

Available for order

Phoenix Contact Availability