OTDC16UT2

ABBOfficial Distributor

By ABB

SKU
ABBOTDC16UT2
MPN
1SCA134387R1001
Weight
0.2 kg
OTDC16UT2 PV Disconnect Switch, Terminal bolt kit included, Handle and shaft need to be ordered separately, Door mounting, UL 600 VDC 16 A single circuit, IEC 660 VDC 16 A single circuit, IEC 1000 VDC 10 A single circuit
Technical Specifications

ABB EcoSolutions

ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available

Dimensions

Product Frame SizeXS
Product Net Width54.5 mm
Product Net Width2.1 in
Product Net Height54.8 mm
Product Net Height2.2 in
Product Net Depth / Length64 mm
Product Net Depth / Length2.5 in
Product Net Weight0.2 kg
Product Net Weight0.4 lb

Technical

Cable Cross-Section2.5 ... 16 mm²
Cable Cross-Section12 ... 6 AWG
Conventional Free-air Thermal Current (Ith)Θ = 40 °C 40 A
Conventional Thermal Current (Ithe)Fully Enclosed 32 A
Degree of ProtectionFront IP20
Handle TypeHandle and shaft not included
Mounting TypeDoor mounting
Number of Circuits1
Number of Poles2P
Operating modeFront
Pollution degree3
Position of Line TerminalsTop In - Bottom Out
Position of Line TerminalsBottom In - Top Out
Positive Opening Operation Torque (Direct Opening Action)0.4 … 0.8 N·m
Power Lossat Rated Operating Conditions per Pole 0.1 W
Protection TypeUL508i RK5 fuselink max. 70A, IEC60947 gPV fuselink max. 80A
Rated Conditional Short-Circuit Current (Inc)(1000 V DC) 10 kA
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)1000 V
Rated Operational Current DC-21B (Ie)(660 V) 16 A
Rated Operational Current DC-21B (Ie)(1000 V) 10 A
Rated Operational Voltage1000 V
Rated Short-Circuit Making Capacity (Icm)(1000 V DC) 1 kA
Rated Short-time Withstand Current Low Voltage (Icw)(1000 V DC) 1 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 1 kA
Recommended Screw DriverMain Circuit Torx
Shaft Diameter6 mm
Shaft Diameter0.24 in
Special FunctionsNo
StandardsUL508i and IEC 60947-1, -3
Switches Operating MechanismMechanism on Top of the Switch
Terminal TypeScrew Terminals
Tightening torqueMain Circuit 1.2 … 1.4 N·m
UtilizationPhotovoltaic
Utilization categorySwitching of resistive loads, including moderate overloads - occasional actuation (DC-21B)
Wire Stripping LengthMain Circuit 51 … 11 mm

Technical UL/CSA

Maximum Operating Voltage600Vdc, UL 508i
Ampere Rating16A,600Vdc,UL508i
Wire Stripping LengthMain Circuit 51 … 11 mm
Recommended Screw DriverMain Circuit Torx
Tightening torqueMain Circuit 1.2 … 1.4 N·m

Why Proax for ABB OTDC16UT2?

Proax is an authorized distributor of ABB OTDC16UT2 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability