The AF38ZB-40-00RT-21 is a 4 pole - 690 V IEC or 600 UL contactor with Ring-Tongue Terminals, controlling motors up to 11 kW / 400 V AC (AC-3) and switching power circuits up to 55 A (AC-1) or 55 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Technical Specifications
Dimensions
Product Net Width | 45 mm |
Product Net Depth / Length | 101 mm |
Product Net Height | 86 mm |
Product Net Weight | 0.39 kg |
Technical
Number of Main Contacts NO | 4 |
Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 0 |
Number of Auxiliary Contacts NC | 0 |
Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives. |
Rated Operational Voltage | Main Circuit 690 V |
Rated Frequency (f) | Control Circuit 50 / 60 Hz |
Rated Frequency (f) | Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A |
Rated Operational Current AC-1 (Ie) | (1000 V) 60 °C 45 A |
Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 55 A |
Rated Operational Current AC-1 (Ie) | (690 V) 70 °C 37 A |
Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 21.2 A |
Rated Operational Current AC-3 (Ie) | (440 V) 60 °C 20 A |
Rated Operational Current AC-3 (Ie) | (500 V) 60 °C 17.6 A |
Rated Operational Current AC-3 (Ie) | (690 V) 60 °C 10.5 A |
Rated Operational Current AC-3 (Ie) | (380 / 400 V) 60 °C 22 A |
Rated Operational Current AC-3 (Ie) | (220 / 230 / 240 V) 60 °C 23.2 A |
Rated Operational Power AC-3 (Pe) | (400 V) 11 kW |
Rated Operational Power AC-3 (Pe) | (415 V) 11 kW |
Rated Operational Power AC-3 (Pe) | (440 V) 11 kW |
Rated Operational Power AC-3 (Pe) | (500 V) 11 kW |
Rated Operational Power AC-3 (Pe) | (690 V) 9 kW |
Rated Operational Power AC-3 (Pe) | (220 / 230 / 240 V) 5.5 kW |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A |
Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 55 A |
Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 60 °C 45 A |
Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 70 °C 37 A |
Rated Operational Current DC-1 (Ie) | (110 V) 3 Poles in Series, 40 °C 55 A |
Rated Operational Current DC-1 (Ie) | (110 V) 3 Poles in Series, 60 °C 45 A |
Rated Operational Current DC-1 (Ie) | (110 V) 3 Poles in Series, 70 °C 37 A |
Rated Operational Current DC-1 (Ie) | (110 V) 4 Poles in Series, 40 °C 55 A |
Rated Operational Current DC-1 (Ie) | (110 V) 4 Poles in Series, 60 °C 45 A |
Rated Operational Current DC-1 (Ie) | (110 V) 4 Poles in Series, 70 °C 37 A |
Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 40 °C 55 A |
Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 60 °C 45 A |
Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 70 °C 37 A |
Rated Operational Current DC-1 (Ie) | (220 V) 4 Poles in Series, 40 °C 55 A |
Rated Operational Current DC-1 (Ie) | (220 V) 4 Poles in Series, 60 °C 45 A |
Rated Operational Current DC-1 (Ie) | (220 V) 4 Poles in Series, 70 °C 37 A |
Rated Operational Current DC-1 (Ie) | (72 V) 1-Pole, 40 °C 55 A |
Rated Operational Current DC-1 (Ie) | (72 V) 1-Pole, 60 °C 45 A |
Rated Operational Current DC-1 (Ie) | (72 V) 1-Pole, 70 °C 37 A |
Rated Operational Current DC-1 (Ie) | (72 V) 2 Poles in Series, 40 °C 55 A |
Rated Operational Current DC-1 (Ie) | (72 V) 2 Poles in Series, 60 °C 45 A |
Rated Operational Current DC-1 (Ie) | (72 V) 2 Poles in Series, 70 °C 37 A |
Rated Operational Current DC-1 (Ie) | (72 V) 3 Poles in Series, 40 °C 55 A |
Rated Operational Current DC-1 (Ie) | (72 V) 3 Poles in Series, 60 °C 45 A |
Rated Operational Current DC-1 (Ie) | (72 V) 3 Poles in Series, 70 °C 37 A |
Rated Operational Current DC-1 (Ie) | (72 V) 4 Poles in Series, 40 °C 55 A |
Rated Operational Current DC-1 (Ie) | (72 V) 4 Poles in Series, 60 °C 45 A |
Rated Operational Current DC-1 (Ie) | (72 V) 4 Poles in Series, 70 °C 37 A |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 690 V |
Rated Insulation Voltage (Ui) | acc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | 6 kV |
Rated Control Circuit Voltage (Uc) | 50 Hz 24 ... 60 V |
Rated Control Circuit Voltage (Uc) | 60 Hz 24 ... 60 V |
Rated Control Circuit Voltage (Uc) | DC Operation 20 ... 60 V |
Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Mounting by Screws (not supplied) | 2 x M4 screws placed diagonally |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP10 |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
Terminal Type | Ring-Tongue Terminals |
Technical UL/CSA
Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
General Use Rating UL/CSA | (600 V AC) 55 A |
Tightening Torque UL/CSA | Control Circuit 11 in·lb |
Tightening Torque UL/CSA | Main Circuit 22 in·lb |
Why Proax for ABB AF38ZB-40-00RT-21?
Proax is an authorized distributor of ABB AF38ZB-40-00RT-21 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | AF38ZB4000RT21 |
Pack Size | 1 |