The figure shows the standard item
2702132
SKU
PHX2702132
MPN
IL PB BK DI8 DO4/EF-XC-PAC
Weight
0.34 kg
This product is Not Cancellable/Not Returnable
Series IL-PB-BK-DI8
IL PB BK DI8 DO4/EF-XC-PAC - Bus coupler
Inline, Bus coupler, PROFIBUS DP, D-SUB-9 female connector, Digital inputs: 8, 24 V DC, connection technology: 3-conductor, Digital outputs: 4, 24 V DC, 500 mA, connection technology: 3-conductor, Extreme conditions version, transmission speed in the local bus: 500 kbps / 2 Mbps, degree of protection: IP20, including Inline connectors and marking fields
- PROFIBUS connection via 9-pos. D-SUB socket
- 8 digital inputs, 4 digital outputs (on-board)
- Connection of a maximum of 16 PCP devices
- DP/V1 for class 1 and class 2 masters
- PROFIBUS data transmission speed of 9.6 kbps to 12 Mbps
- I&M functions
- Diagnostic and status indicators
- IO-Link call
- Can be used under extreme ambient conditions
- Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
- Coated PCBs
Technical Specifications
Dimensions
| Width | 80 mm |
| Height | 119.8 mm |
| Depth | 71.5 mm |
| Note on dimensions | Specfications with connectors |
Material specifications
| Color | green |
PROFIBUS DP
| No. of channels | 1 |
| Connection Method | D-SUB-9 female connector |
| Number of Positions | 9 |
| Transmission Speed | 9.6 kbps ... 12 Mbps |
Inline local bus
| Connection Method | Inline data jumper |
| Transmission Speed | 500 kbps / 2 Mbps (automatic detection, no combined system) |
Fieldbus: Local bus gateway
| Max. number of local bus devices | 61 (The on-board I/Os are two devices) |
System limits
| Number of supported devices | max. 63 (per station) |
| Number of local bus devices that can be connected | max. 61 (The on-board I/Os are two devices) |
| Number of devices with parameter channel | max. 16 |
| Number of supported branch terminals with remote bus branch | 0 |
| Response time of I/Os | typ. 4 ms (aligned I/Os; transmission speed: PROFIBUS 1.5 Mbps, local bus 500 kbps) |
Module
| ID code (hex) | 0B50 |
| Input address area | 8 bit (or 1 byte, selection in the GSD file) |
| Output address area | 4 bit (or 1 byte, selection in the GSD file) |
| Register length | 16 bit |
Digital:
| Input name | Digital inputs |
| Description of the input | EN 61131-2 type 1 |
| Number of Inputs | 8 |
| Connection Method | Inline connector |
| Connection technology | 3-conductor |
| Input Voltage | 24 V DC |
| Input voltage range "0" signal | -30 V DC ... 5 V DC |
| Input voltage range "1" signal | 15 V DC ... 30 V DC |
| Nominal input voltage UIN | 24 V DC |
| Nominal input current at UIN | typ. 3 mA |
| Typical input current per channel | typ. 3 mA |
| Typical response time | approx. 500 µs |
| Delay at signal change from 0 to 1 | 2.9 ms |
| Delay at signal change from 1 to 0 | 2.9 ms |
| Protective circuit | Reverse polarity protection; Suppressor diode |
| Output name | Digital outputs |
| Connection Method | Inline connector |
| Connection technology | 3-conductor |
| Number of Outputs | 4 |
| Protective circuit | Short-circuit and overload protection; Freewheeling circuit in the output driver |
| Output Voltage | 24 V DC -1 V (At nominal current) |
| Maximum Output Current per module | max. 2 A |
| Nominal Output Voltage | 24 V DC |
| Output current when switched off | max. 10 µA (When not loaded, a voltage can be measured even at an output that is not set.) |
| Nominal load, inductive | 12 VA (1.2 H, 48 Ω) |
| Nominal load, lamp | 12 W |
| Nominal load, ohmic | 12 W |
| Reverse voltage resistance to short pulses | Reverse voltage proof |
| Behavior with overload | Auto restart |
| Behavior with inductive overload | Output can be destroyed |
| Behavior at voltage switch-off | The output follows the power supply without delay |
| Signal delay | typ. 2.9 ms |
| Overcurrent shut-down | min. 0.7 A |
Product properties
| Product family | Inline |
| Type | modular |
| Type | Inline |
| Scope of delivery | including Inline connectors and marking fields |
| No. of channels | 12 |
| Special Properties | Extreme conditions version |
| Diagnostics messages | Short-circuit or overload of the digital outputs yes |
| Diagnostics messages | Sensor supply failure yes |
| Diagnostics messages | Failure of the actuator supply yes |
Electrical properties
| Power dissipation | typ. 1.7 W (entire device) |
Potentials
| Power consumption | typ. 1.7 W (entire device) |
| Supply Voltage | 24 V DC (via Inline connector) |
| Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current draw | max. 0.98 A (with max. number of connected I/O terminal blocks) |
| Current draw | min. 80 mA (without connected I/O terminal blocks) |
Potentials: Communications power (UL)
| Supply Voltage | 7.5 V DC |
Potentials: Supply of analog modules (UANA)
| Supply Voltage | 24 V DC |
| Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Potentials: Main circuit supply (UM)
| Supply Voltage | 24 V DC (via Inline connector) |
| Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current draw | max. 8 A DC |
| Current draw | min. 3 mA (without connected peripherals) |
Potentials: Segment circuit supply (US)
| Supply Voltage | 24 V DC (via Inline connector) |
| Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current draw | max. 8 A DC |
| Current draw | min. 6 mA (without connected peripherals) |
Connection technology
| Connection name | Inline connector |
Conductor connection
| Connection Method | Spring-cage connection |
| Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.08 mm² ... 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 |
| Stripping length | 8 mm |
Inline connector
| Connection Method | Spring-cage connection |
| Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
| Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 |
| Stripping length | 8 mm |
Ambient conditions
| Ambient Temperature (Operation) | -25 °C ... 55 °C |
| Ambient Temperature (Operation) | -40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) |
| Degree of Protection | IP20 |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
Standards and Regulations
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting
| Mounting Type | DIN rail mounting |
Accessories
SUBCON-PLUS-PROFIB/PG/SC2 - D-SUB connector, 9-pos., male connector, 35° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; screw connection terminal blocks
SUBCON-PLUS-PROFIB/90/PG/IDC - D-SUB connector, 9-pos., male connector, 90° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; IDC terminal block connection
SUBCON-PLUS-PROFIB/90/PG/SC - D-SUB connector, 9-pos., male connector, 90° cable entry, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8; screw connection terminal blocks
Why Proax for Phoenix Contact 2702132?
Proax is an authorized distributor of Phoenix Contact 2702132 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended
IL PB BK DI8 DO4/EF-PAC - Inline, Bus coupler, PROFIBUS DP, D-SUB-9 female connector, Digital inputs: 8, 24 V DC, connection technology: 3-conductor, Digital outputs: 4, 24 V DC, 500 mA, connection technology: 3-conductor, transmission speed in the local bus: 500 kbps / 2 Mbps, degree of protection: IP20, including Inline connectors and marking fields
IL PB BK DI8 DO4-PAC - Inline, Bus coupler, PROFIBUS DP, D-SUB-9 female connector, Digital inputs: 8, 24 V DC, connection technology: 3-conductor, Digital outputs: 4, 24 V DC, 500 mA, connection technology: 3-conductor, transmission speed in the local bus: 500 kbps / 2 Mbps, degree of protection: IP20, including Inline connectors and marking fields