Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
TTC-6-2X1-F-M-24DC-PT-I
Weight
0.038 kg
This product is Not Cancellable/Not Returnable
Series TTC

TTC-6-2X1-F-M-24DC-PT-I - Surge protection device

Surge protection with integrated status indicator and disconnect knife for two signal wires with common reference potential. Indirect grounding via gas discharge tube, e.g., Digital IN/OUT. Can be used in safety-related circuits up to SIL 3.

  • Space-saving and cost-saving with a narrow overall width of just 6 mm
  • Continuous monitoring of protective devices, plus mechanical status indicator with optional remote signaling
  • Finding the right product for all possible requirements in MCR applications is easy, thanks to the complete range of products with customized features
  • Signal circuits easily interrupted for maintenance work, thanks to vertical knife disconnection
Technical Specifications

Product properties

Product familyTERMITRAB complete
IEC test classificationC1
IEC test classificationC2
IEC test classificationC3
IEC test classificationD1
TypeDIN rail module, one-piece

Insulation characteristics

Overvoltage categoryIII
Pollution degree2

Electrical properties

Nominal voltage UN24 V DC

Connection data

Connection MethodPush-in connection
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section rigid0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 12

Dimensions

Width6.2 mm +0.1 mm
Height105.8 mm
Depth83.5 mm (incl. DIN rail 7.5 mm)

Material specifications

Colorgray (RAL 7042)
Colorlight grey (RAL 7035)
Flammability rating according to UL 94V-0
Insulating materialPBT
Housing MaterialPBT

Mechanical data

Open side panelNo

Protective circuit

Direction of actionLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Maximum continuous voltage UC30 V DC
Maximum continuous voltage UC21 V AC
Rated current600 mA (40 °C)
Operating effective current IC at UC≤ 5 µA
Residual current IPE≤ 1 µA
Nominal discharge current In (8/20) µs (line-ground)5 kA
Nominal discharge current In (8/20) µs (line-signal ground)5 kA
Pulse discharge current Iimp (10/350) µs (line-earth)0.5 kA
Pulse discharge current Iimp (10/350) µs (line-signalground)0.5 kA
Total discharge current Itotal (8/20) µs10 kA
Voltage protection level Up (line-earth)≤ 750 V (C1 - 1 kV / 500 A)
Voltage protection level Up (line-earth)≤ 750 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-earth)≤ 1.1 kV (C3 - 25 A)
Voltage protection level Up (line-earth)≤ 1.15 kV (C3 - 100 A)
Voltage protection level Up (line-signalground)≤ 140 V (C1 - 1 kV / 500 A)
Voltage protection level Up (line-signalground)≤ 130 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-signalground)≤ 45 V (C3 - 25 A)
Voltage protection level Up (line-signalground)≤ 50 V (C3 - 100 A)
Voltage protection level Up static (line-earth)≤ 750 V (C1 - 1 kV / 500 A)
Voltage protection level Up static (line-earth)≤ 750 V (C2 - 10 kV / 5 kA)
Voltage protection level Up static (line-signalground)≤ 55 V (C1 - 1 kV / 500 A)
Voltage protection level Up static (line-signalground)≤ 80 V (C2 - 10 kV / 5 kA)
Response time tA (line-earth)≤ 100 ns
Response time tA (line-signalground)≤ 1 ns
Input attenuation aE, asym.typ. 0.3 dB (≤ 270 kHz/150 Ω)
Cut-off frequency fg (3 dB), asym. (signal ground) in 150 Ω systemtyp. 960 kHz
Capacity (line-signalground)typ. 2.2 nF
Resistance per path1.65 Ω ±20 %
Surge protection fault messageoptical
Max. required back-up fuse630 mA (FF)
Impulse durability (line-earth)C1 - 1 kV / 500 A
Impulse durability (line-earth)C2 - 10 kV / 5 kA
Impulse durability (line-earth)C3 - 100 A
Impulse durability (line-earth)D1 - 500 A
Impulse durability (line-signalground)C1 - 1 kV / 500 A
Impulse durability (line-signalground)C2 - 10 kV / 5 kA
Impulse durability (line-signalground)C3 - 100 A
Impulse durability (line-signalground)D1 - 500 A
Pulse reset time (line-earth)≤ 30 ms
Pulse reset time (line-signalground)≤ 300 ms

Additional technical data

Max. total discharge current I total max (8/20) µs20 kA (1x)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 85 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 4000 m (amsl)
Permissible humidity (operation)5 % ... 95 %

Standards and Regulations

Standards/specificationsIEC 61643-21
Note2000 + corrigendum 2001 + A1:2008, modified + A2:2012

EN 61643-21

Standards/specificationsEN 61643-21
Note2001 + A1:2009 + A2:2013

Mounting

Mounting TypeDIN rail: TH 35 - 7.5 mm
Accessories

Why Proax for Phoenix Contact 2906776?

Proax is an authorized distributor of Phoenix Contact 2906776 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability