
AF460-30-11-68
By ABB
SKU
ABBAF460301168
MPN
1SFL597001R6811
Weight
10.6 kg
Series AF 3-pole Contactors
The AF460-30-11-68 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 250 kW / 400 V AC (AC-3) or 400 hp / 480 V UL and switching power circuits up to 700 A (AC-1) or 650 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
AF 3-pole Contactors
ABB's AF series includes a variety of 3-pole contactors designed for controlling 3-phase motors and power circuits. These contactors are categorized into several sub-series based on their current ratings and applications.
Each sub-series features integrated electronic coils that reduce energy consumption by up to 80%, provide surge protection, and allow operation across wide voltage ranges without coil changes. ABB also offers auxiliary contact blocks and accessories to enhance functionality
Technical Specifications
Dimensions
| Product Net Width | 186 mm |
| Product Net Depth / Length | 216 mm |
| Product Net Height | 278 mm |
| Product Net Weight | 10.6 kg |
| Dimension Diagram | 53540919-59 |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 700 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 700 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 55 °C 600 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 60 °C 600 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 70 °C 480 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 700 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 55 °C 600 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 70 °C 480 A |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 460 A |
| Rated Operational Current AC-3 (Ie) | (440 V) 55 °C 460 A |
| Rated Operational Current AC-3 (Ie) | (500 V) 55 °C 460 A |
| Rated Operational Current AC-3 (Ie) | (690 V) 55 °C 400 A |
| Rated Operational Current AC-3 (Ie) | (1000 V) 55 °C 200 A |
| Rated Operational Current AC-3 (Ie) | (380 / 400 V) 55 °C 460 A |
| Rated Operational Current AC-3 (Ie) | (220 / 230 / 240 V) 55 °C 460 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 1-Pole, 40 °C 700 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 700 A |
| Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 40 °C 700 A |
| Rated Operational Current DC-1 (Ie) | (600 V) 3 Poles in Series, 40 °C 700 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 1-Pole, 40 °C 700 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 700 A |
| Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 40 °C 700 A |
| Rated Operational Current DC-3 (Ie) | (600 V) 3 Poles in Series, 40 °C 700 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 1-Pole, 40 °C 700 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 700 A |
| Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 40 °C 700 A |
| Rated Operational Current DC-5 (Ie) | (600 V) 3 Poles in Series, 40 °C 700 A |
| Rated Operational Power AC-3 (Pe) | (415 V) 250 kW |
| Rated Operational Power AC-3 (Pe) | (440 V) 250 kW |
| Rated Operational Power AC-3 (Pe) | (500 V) 315 kW |
| Rated Operational Power AC-3 (Pe) | (690 V) 355 kW |
| Rated Operational Power AC-3 (Pe) | (1000 V) 280 kW |
| Rated Operational Power AC-3 (Pe) | (380 / 400 V) 250 kW |
| Rated Operational Power AC-3 (Pe) | (220 / 230 / 240 V) 132 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Short-Circuit Protective Devices | gG Type Fuses 1.5 ... 1.8 In A |
| Short-Circuit Protective Devices | gG Type Fuses 800 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 3100 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4600 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4400 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 2500 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4500 A |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| Rated Insulation Voltage (Ui) | acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Maximum Electrical Switching Frequency | (AC-2 / AC-4) 60 cycles per hour |
| Maximum Electrical Switching Frequency | (AC-3) 300 cycles per hour |
| Mechanical Durability | 3 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 24 ... 60 V |
| Rated Control Circuit Voltage (Uc) | DC Operation 24 ... 60 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage DC 7.5 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 900 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 900 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage DC 900 V·A |
| Power Loss | at Rated Operating Conditions per Pole 21 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 45 ... 55 ms |
| Operate Time | Between Coil De-energization and NO Contact Opening 48 ... 58 ms |
| Operate Time | Between Coil Energization and NC Contact Opening 45 ... 115 ms |
| Operate Time | Between Coil Energization and NO Contact Closing 50 ... 120 ms |
| Connecting Capacity Main Circuit | Bar 47 mm² |
| Connecting Capacity Main Circuit | Rigid Al-Cable 2x240 mm² |
| Connecting Capacity Main Circuit | Rigid Cu-Cable 240 mm² |
| Connecting Capacity Main Circuit | Rigid Cu-Cable 2x240 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible 1x0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible 2x0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Solid 2 x 1 ... 4 mm² |
| Connecting Capacity Auxiliary Circuit | Stranded 2 x 1 .... 4 mm² |
| Connecting Capacity | Bar 47 mm² |
| Connecting Capacity | Rigid Al-Cable 2x240 mm² |
| Connecting Capacity | Rigid Cu-Cable 2x240 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Connecting Terminals (delivered in open position) Main Poles | M 3.5 (+,-) pozidriv 2 screw with cable clamp |
| Recommended Screw Driver | Main Circuit M10 |
| Recommended Screw Driver | Control Circuit Pozidriv 2 |
| Recommended Screw Driver | Control Circuit M3.5 |
| Tightening torque | Cable Lug 35 N·m |
| Tightening torque | Main Circuit 35 N·m |
| Terminal Type | Main Circuit: Bars |
| Suitable for Product Class | Block ContactorsBlock Contactors |
| Product Name | Block Contactor |
Technical UL/CSA
| NEMA Size | 6 |
| Horsepower Rating NEMA | (200 V AC) Three Phase 150 Hp |
| Horsepower Rating NEMA | (230 V AC) Three Phase 200 Hp |
| Horsepower Rating NEMA | (460 V AC) Three Phase 400 Hp |
| Horsepower Rating NEMA | (575 V AC) Three Phase 400 Hp |
| Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
| General Use Rating UL/CSA | (1000 V AC) 650 A |
| General Use Rating UL/CSA | (600 V AC) 650 A |
| Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 150 Hp |
| Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 150 hp |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 150 hp |
| Horsepower Rating UL/CSA | (208 V AC) Three Phase 150 hp |
| Horsepower Rating UL/CSA | (220 ... 240 V AC) Three Phase 200 Hp |
| Horsepower Rating UL/CSA | (220 ... 240 V AC) Three Phase 200 hp |
| Horsepower Rating UL/CSA | (440 ... 480 V AC) Three Phase 400 Hp |
| Horsepower Rating UL/CSA | (440 ... 480 V AC) Three Phase 400 hp |
| Horsepower Rating UL/CSA | (550 ... 600 V AC) Three Phase 500 Hp |
| Horsepower Rating UL/CSA | (550 ... 600 V AC) Three Phase 500 hp |
| Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 477 A |
| Full Load Amps Motor Use | (550 ... 600 V AC) Three Phase 472 A |
ABB EcoSolutions
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility |
| End Of Life Disassembling Instructions | 1SFC100112M0003 |
| Environmental Product Declaration - EPD | 1SFC100105D0201 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 63.1 % |
| Sustainable Material Content in Product (wt. %) | Recycled Metal - 37 % |
Why Proax for ABB AF460-30-11-68?
Proax is an authorized distributor of ABB AF460-30-11-68 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Alternate Names | AF460301168 |
| Pack Size | 1 |
Recommended



















