Contrôleurs de sécurité programmables
Tina 2B is used for adaptation of devices with two positively driven force-guided contacts like emergency stop buttons and key switches, to the DYNlink solution. Tina 2B is placed inside the safety device enclosure.Tina is available in several versions depending on the type of safety component that is connected to the Vital, Pluto or B&R X20 circuit.
Pas en stock
Tina 3Aps is used for adaptation of devices with two positively driven force-guided contacts like E-stop buttons and key switches, to the DYNlink solution, with extra conductor for the supply of the safety device. Tina 3A is mounted directly on the device enclosure to a M20 cable entry and has a M12-5 male connector for connection to the DYNlink loop. Connection to +24VDC and 0V on the device side.
Pas en stock
Pluto is a cost effective, powerful and compact safety PLC for all machine safety applications. Most safety devices on the market can be connected directly to Pluto and multiple safety sensors can be connected to a single input and still achieve the highest safety level. Programming is done easily in the accompanying software Pluto Manager.Safety PLC with AS-i bus and Pluto safety bus. Totally 42 I/O: 20 failsafe inputs + 16 non-failsafe outputs/failsafe inputs + 4 individually failsafe relay outputs + 2 individually failsafe transistor outputs.
Pas en stock
Identifier, read/write, for assigning an address to the Pluto it is connected to and for storage of the AS-i safety codes. Must be used with Pluto AS-i and Pluto B42 AS-i and can be used for all Pluto types. The identification number is programmable, i.e. the user can choose the number.IDFIX is an identifier circuit which gives each Pluto an address on the bus. It contains an identification code which can be read by the system. The identification code is declared in the PLC program so that the correct part of the PLC program is executed by each specific Pluto. The use of IDFIX is mandatory in a multi-Pluto project, but voluntary if a unit works alone. If one Pluto in a multi-Pluto project needs to be replaced it is possible to let the new Pluto selfload the PLC program from another Pluto on the bus. The IDFIX will ensure that the new Pluto has the correct address on the bus.
Pas en stock
External program memory, 2.5 kbyte. For projects with only one Pluto the memory can store the PLC program. Can also be used to give Pluto AS-i a specific address.IDFIX is an identifier circuit which gives each Pluto an address on the bus. It contains an identification code which can be read by the system. The identification code is declared in the PLC program so that the correct part of the PLC program is executed by each specific Pluto. The use of IDFIX is mandatory in a multi-Pluto project, but voluntary if a unit works alone. If one Pluto in a multi-Pluto project needs to be replaced it is possible to let the new Pluto selfload the PLC program from another Pluto on the bus. The IDFIX will ensure that the new Pluto has the correct address on the bus.
Pas en stock