Contrôleurs de sécurité programmables
Gateway for 2-way communication between the Pluto bus and Ethernet. Ethernet protocol Modbus TCP.With the use of a Gateway device, Pluto can communicate with other control systems and thereby form a part of a larger network. The unit has a common interface with Pluto, i.e. the same cabling and the Pluto Manager software can be used for servicing and where necessary programming.
Pas en stock
Safety Remote I/O Terminal (CIP-S) with 2 port switching hub and 12 PNP S-Digital Inputs (12 Test Pulses) / 4 PNP S-Digital Output
Tina 8A is a connection block for series connection of up to eight DYNlink devices. Eight M12-5 female connectors for the sensors are available on the device. The information signal of each device can be wired separately. The cable used for the connection to the Tina 8A should have a diameter 7 - 12 mm. Unused M12-connectors on Tina 8A must be equipped with Tina 1A blind plugs.The Tina devices adapt the DYNlink safety circuit in Vital, Pluto and B&R X20 to safety components with mechanical contacts, such as E-stops, switches and light beams/curtains with dual outputs.Tina is available in several versions depending on the type of safety component that is connected to the Vital, Pluto or B&R X20 circuit.
Pas en stock
2TLA020054R1800, Tina 12A Connection block with adaption unit for dynamic circuits. Two M12 8-pole connectors for sensor input. For example Dalton and Magne locks.
Tina 7A is used for adaptation of devices with two positively driven force-guided contacts like emergency stop buttons and key switches, to the DYNlink solution. Tina 7A is mounted on a DIN rail in the electrical cabinets and the connected safety device(s) must be mounted on the same cabinet, e.g. an emergency-stop button mounted on the cabinet. Electrical connection is made via detachable terminal blocks.
Pluto is a cost effective, powerful and compact safety PLC for all machine safety applications. Most safety devices on the market can be connected directly to Pluto and multiple safety sensors can be connected to a single input and still achieve the highest safety level. Programming is done easily in the accompanying software Pluto Manager.Safety PLC with Pluto safety bus. Totally 20 I/O: 8 failsafe inputs + 8 non-failsafe outputs/failsafe inputs + 2 individually failsafe relay outputs + 2 individually failsafe transistor outputs. Current monitoring on Q16 + Q17. NOTE: Version 2 hardware/processor.
Pas en stock
TIna 10C v2 adapts the OSSD outputs of ABB optical safety devices to the DYNlink solution with possibility to power the transmitter. Tina 10C has one M12-5 male connector towards the DYNlink loop, one M12-8 female connector towards the OSSD device and one M12-5 female connector for the supply of the transmitter (0V and +24VDC).The Tina devices adapt the DYNlink safety circuit in Vital, Pluto and B&R X20 to safety components with mechanical contacts, such as E-stops, switches and light beams/curtains with dual outputs.Tina is available in several versions depending on the type of safety component that is connected to the Vital, Pluto or B&R X20 circuit.
Pas en stock
Fixa is a handheld terminal for:• Addressing and configuration of AS-i bus sensors.• Addressing and configuration of sensors for the ABB StatusBus.• Test of sensors for the AS-i bus, sensors for the ABB DYNlink safety circuit, and common sensors with PNP output.Three batteries of type NiMH AAA rechargeable must be used. Batteries are not included.
Pas en stock
Tina 11A is a connection block for serie connection of two DYNlink devices with M12-5 connectors. Two M12-5 female connectors for the devices and one M12-5 male connector towards the DYNlink loop.The Tina devices adapt the DYNlink safety circuit in Vital, Pluto and B&R X20 to safety components with mechanical contacts, such as E-stops, switches and light beams/curtains with dual outputs.Tina is available in several versions depending on the type of safety component that is connected to the Vital, Pluto or B&R X20 circuit.
Pas en stock
TIna 10A v2 adapts the OSSD outputs of ABB optical safety devices to the DYNlink solution. Tina 10A v2 has one M12-5 male connector towards the DYNlink loop and one M12-8 female connector towards the OSSD device.The Tina devices adapt the DYNlink safety circuit in Vital, Pluto and B&R X20 to safety components with mechanical contacts, such as E-stops, switches and light beams/curtains with dual outputs.Tina is available in several versions depending on the type of safety component that is connected to the Vital, Pluto or B&R X20 circuit.
Pas en stock
Tina 2A is used for adaptation of devices with two positively driven force-guided contacts like emergency stop buttons and key switches, to the DYNlink solution. Tina 2A is mounted directly on the device enclosure to a M20 cable entry.Tina is available in several versions depending on the type of safety component that is connected to the Vital, Pluto or B&R X20 circuit.