Composants de sécurité des machines
Tina 1A blind plug is connected to the unused M12 connectors of the connection blocks Tina 4A or Tina 8A. M12-5 male connector.The Tina devices adapt the DYNlink safety circuit in Vital, Pluto and B&R X20 to safety components with mechanical contacts, such as E-stops, switches and light beams/curtains with dual outputs.Tina is available in several versions depending on the type of safety component that is connected to the Vital, Pluto or B&R X20 circuit.
Pas en stock
Tina 4A is a connection block for series connection of up to four DYNlink devices. Four M12-5 female connectors for the sensors are available on the device. The information signal of each device can be wired separately. The cable used for the connection to the Tina 4A should have a diameter 7 - 12 mm. Unused M12-connectors on Tina 4A must be equipped with Tina 1A blind plugs.The Tina devices adapt the DYNlink safety circuit in Vital, Pluto and B&R X20 to safety components with mechanical contacts, such as E-stops, switches and light beams/curtains with dual outputs.Tina is available in several versions depending on the type of safety component that is connected to the Vital, Pluto or B&R X20 circuit.
Pas en stock
Emergency stop button in Smile enclosure, Tina adaptation unit to DYNlink included, Status LED in button, 1 x M12-5 male connector.
Identifier, read only, for assigning an address to the Pluto it is connected to. Each Pluto connected to the Pluto safety bus needs an IDFIX. The IDFIX number is fixed at delivery.IDFIX is an identifier circuit which gives each Pluto an address on the bus. It contains an identification code which can be read by the system. The identification code is declared in the PLC program so that the correct part of the PLC program is executed by each specific Pluto. The use of IDFIX is mandatory in a multi-Pluto project, but voluntary if a unit works alone. If one Pluto in a multi-Pluto project needs to be replaced it is possible to let the new Pluto selfload the PLC program from another Pluto on the bus. The IDFIX will ensure that the new Pluto has the correct address on the bus.
Pas en stock
Safety Light Curtain, F3SG-SRB Standard, Type 4, 85 mm resolution, range 0.3 to 20.0 m, height 280 mm, PNP/NPN
Pas en stock
Gateway for 2-way communication between the Pluto bus and Ethernet. Ethernet protocol Modbus TCP.With the use of a Gateway device, Pluto can communicate with other control systems and thereby form a part of a larger network. The unit has a common interface with Pluto, i.e. the same cabling and the Pluto Manager software can be used for servicing and where necessary programming.
Pas en stock