Composants de sécurité des machines
Pluto is a cost effective, powerful and compact safety PLC for all machine safety applications. Most safety devices on the market can be connected directly to Pluto and multiple safety sensors can be connected to a single input and still achieve the highest safety level. Programming is done easily in the accompanying software Pluto Manager.Safety PLC with Pluto safety bus. Totally 20 I/O: 8 failsafe inputs + 8 non-failsafe outputs/failsafe inputs + 2 individually failsafe relay outputs + 2 individually failsafe transistor outputs.
Pas en stock
Safety laser scanner with measurement data, safety radius 4m, warning zone 15 m, replacement sensor block
M12-C1012 is a shielded cable with straight M12-5 male and female connectors. The five conductors have a cross section of 0.34 mm2. The shield is connected to pin 3 (0V) on the male connector. The jacket is made of black PVC. The length of the cable is 10 meters.
M12-C112 is a shielded cable with straight M12-5 male and female connectors. The five conductors have a cross section of 0.34 mm2. The shield is connected to pin 3 (0V) on the male connector. The jacket is made of black PVC. The length of the cable is 1 meter.
Pluto is a cost effective, powerful and compact safety PLC for all machine safety applications. Most safety devices on the market can be connected directly to Pluto and multiple safety sensors can be connected to a single input and still achieve the highest safety level. Programming is done easily in the accompanying software Pluto Manager.Safety PLC. Totally 20 I/O: 8 failsafe inputs + 8 non-failsafe outputs/failsafe inputs + 2 individually failsafe relay outputs + 2 individually failsafe transistor outputs. (Without Pluto safety bus). NOTE: Version 2 hardware/processor.
Pluto is a cost effective, powerful and compact safety PLC for all machine safety applications. Most safety devices on the market can be connected directly to Pluto and multiple safety sensors can be connected to a single input and still achieve the highest safety level. Programming is done easily in the accompanying software Pluto Manager.Safety PLC. Totally 46 I/O: 24 failsafe inputs + 16 non-failsafe outputs/failsafe inputs + 4 individually failsafe relay outputs + 2 individually failsafe transistor outputs. (Without Pluto safety bus)
Tina 3A is used for adaptation of devices with two positively driven force-guided contacts like emergency stop buttons and key switches, to the DYNlink solution. Tina 3A is mounted directly on the device enclosure to a M20 cable entry and has a M12-5 male connector for connection to the DYNlink loop.Tina is available in several versions depending on the type of safety component that is connected to the Vital, Pluto or B&R X20 circuit.



















