Distributeur Officiel
By ABB
SKU
MPN
2TLA020070R2300
Identifier, read/write, for assigning an address to the Pluto it is connected to and for storage of the AS-i safety codes. Must be used with Pluto AS-i and Pluto B42 AS-i and can be used for all Pluto types. The identification number is programmable, i.e. the user can choose the number.
IDFIX is an identifier circuit which gives each Pluto an address on the bus. It contains an identification code which can be read by the system. The identification code is declared in the PLC program so that the correct part of the PLC program is executed by each specific Pluto. The use of IDFIX is mandatory in a multi-Pluto project, but voluntary if a unit works alone. If one Pluto in a multi-Pluto project needs to be replaced it is possible to let the new Pluto selfload the PLC program from another Pluto on the bus. The IDFIX will ensure that the new Pluto has the correct address on the bus.
Documents
Spécifications techniques
Dimensions
Produit Longueur Net | 200 mm |
Produit Hauteur Net | 7 mm |
Produit Largeur Net | 12 mm |
Poids net | 0,01 kg |
Technique
Diagnostic Coverage | élevé |
Performance Level (PL) | Up to e |
Adapté pour | Pluto AS-i v2, Pluto B42 AS-i |
Pourquoi Proax pour ABB IDFIX-DATA?
Proax est un distributeur autorisé de ABB IDFIX-DATA et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!
Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!
Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Informations complémentaires
Autres noms | IDFIXDATA |
Taille de l'emballage | 1 |
Recommandé
- External program memory, 2.5 kbyte. For projects with only one Pluto the memory can store the PLC program. Can also be used to give Pluto AS-i a specific address.IDFIX is an identifier circuit which gives each Pluto an address on the bus. It contains an identification code which can be read by the system. The identification code is declared in the PLC program so that the correct part of the PLC program is executed by each specific Pluto. The use of IDFIX is mandatory in a multi-Pluto project, but voluntary if a unit works alone. If one Pluto in a multi-Pluto project needs to be replaced it is possible to let the new Pluto selfload the PLC program from another Pluto on the bus. The IDFIX will ensure that the new Pluto has the correct address on the bus.
- Identifier, read/write, for assigning an address to the Pluto it is connected to. Each Pluto connected to the Pluto safety bus needs an IDFIX. The IDFIX number is programmable, i.e. the user can choose the number.IDFIX is an identifier circuit which gives each Pluto an address on the bus. It contains an identification code which can be read by the system. The identification code is declared in the PLC program so that the correct part of the PLC program is executed by each specific Pluto. The use of IDFIX is mandatory in a multi-Pluto project, but voluntary if a unit works alone. If one Pluto in a multi-Pluto project needs to be replaced it is possible to let the new Pluto selfload the PLC program from another Pluto on the bus. The IDFIX will ensure that the new Pluto has the correct address on the bus.
- Identifier, read only, for assigning an address to the Pluto it is connected to. Each Pluto connected to the Pluto safety bus needs an IDFIX. The IDFIX number is fixed at delivery.IDFIX is an identifier circuit which gives each Pluto an address on the bus. It contains an identification code which can be read by the system. The identification code is declared in the PLC program so that the correct part of the PLC program is executed by each specific Pluto. The use of IDFIX is mandatory in a multi-Pluto project, but voluntary if a unit works alone. If one Pluto in a multi-Pluto project needs to be replaced it is possible to let the new Pluto selfload the PLC program from another Pluto on the bus. The IDFIX will ensure that the new Pluto has the correct address on the bus.
- External program memory, 10 kbyte. For projects with only one Pluto the memory can store the PLC program. Can also be used to give Pluto AS-i a specific address.IDFIX is an identifier circuit which gives each Pluto an address on the bus. It contains an identification code which can be read by the system. The identification code is declared in the PLC program so that the correct part of the PLC program is executed by each specific Pluto. The use of IDFIX is mandatory in a multi-Pluto project, but voluntary if a unit works alone. If one Pluto in a multi-Pluto project needs to be replaced it is possible to let the new Pluto selfload the PLC program from another Pluto on the bus. The IDFIX will ensure that the new Pluto has the correct address on the bus.
- Pluto is a cost effective, powerful and compact safety PLC for all machine safety applications. Most safety devices on the market can be connected directly to Pluto and multiple safety sensors can be connected to a single input and still achieve the highest safety level. Programming is done easily in the accompanying software Pluto Manager.Safety PLC with AS-i bus and Pluto safety bus. Totally 42 I/O: 20 failsafe inputs + 16 non-failsafe outputs/failsafe inputs + 4 individually failsafe relay outputs + 2 individually failsafe transistor outputs.
- Pluto safe absolute encoder RHA 597, single turn, 2m cable, hollow shaft, 12mm hole.Together with Pluto, rotational absolute encoders can be used for safe position and speed determination of machine. The programming is done with ready made function blocks in Pluto Manager.Safety level up to PL e/SIL3.
- Pluto is a cost effective, powerful and compact safety PLC for all machine safety applications. Most safety devices on the market can be connected directly to Pluto and multiple safety sensors can be connected to a single input and still achieve the highest safety level. Programming is done easily in the accompanying software Pluto Manager.Safety PLC with AS-i bus and Pluto safety bus. Totally 12 I/O: 4 failsafe inputs + 4 non-failsafe outputs/failsafe inputs + 2 individual failsafe relay outputs + 2 individual failsafe transistor outputs.
- Pluto is a cost effective, powerful and compact safety PLC for all machine safety applications. Most safety devices on the market can be connected directly to Pluto and multiple safety sensors can be connected to a single input and still achieve the highest safety level. Programming is done easily in the accompanying software Pluto Manager.Safety PLC with Pluto safety bus. Totally 46 I/O: 24 failsafe inputs + 16 non-failsafe outputs/failsafe inputs + 4 individually failsafe relay outputs + 2 individually failsafe transistor outputs.
- Pluto is a cost effective, powerful and compact safety PLC for all machine safety applications. Most safety devices on the market can be connected directly to Pluto and multiple safety sensors can be connected to a single input and still achieve the highest safety level. Programming is done easily in the accompanying software Pluto Manager.Safety PLC. Totally 46 I/O: 24 failsafe inputs + 16 non-failsafe outputs/failsafe inputs + 4 individually failsafe relay outputs + 2 individually failsafe transistor outputs. (Without Pluto safety bus)