A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Magnetically latch, control voltage 220-240 V, AC/DC latch
Spécifications techniques

Dimensions

Produit Largeur Net90 mm
Produit Longueur Net156.5 mm
Produit Hauteur Net148 mm
Poids net1,8 kg

Technique

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
TensionCircuit principal 1000 V
Fréquence assignée (f)Circuit principal 50 / 60 Hz
Courant thermique conventionnel à l’air libre (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 160 A
Courant assignée d’emploi AC-1 (Ie)(690 V) 40 °C 160 A, (690 V) 55 °C 145 A, (690 V) 70 °C 130 A
Courant assignée d’emploi AC-3 (Ie)(415 V) 55 °C 110 A, (440 V) 55 °C 100 A, (500 V) 55 °C 100 A, (690 V) 55 °C 82 A, (1000 V) 55 °C 30 A, (380 / 400 V) 55 °C 110 A, (220 / 230 / 240 V) 55 °C 110
Puissance assignée d’emploi AC-3 (Pe)(415 V) 59 kW, (440 V) 59 kW, (500 V) 59 kW, (690 V) 75 kW, (1000 V) 40 kW, (380 / 400 V) 55 kW, (220 / 230 / 240 V) 30 kW
Pouvoir assigné de coupure AC-38 x Ie AC-3
Pouvoir assigné de fermeture AC-310 x Ie AC-3
Dispositif de protection contre les courts-circuitsgG Type Fuses 160 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 300 cycles per hour
Courant assignée d’emploi DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A, (220 V) 3 Poles in Series, 40 °C 160 A
Courant assignée d’emploi DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A, (220 V) 3 Poles in Series, 40 °C 160 A
Courant assignée d’emploi DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A, (220 V) 3 Poles in Series, 40 °C 160 A
Tension assignée d’isolement (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 600 V
Tension assignée de tenue aux chocs (Uimp)Circuit principal 8 kV
Durabilite mecanique10 million
Maximum Mechanical Switching Frequency300 cycles per hour
Plage d'utilisation de la bobine selon(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 48 ... 130 V, 60 Hz 48 ... 130 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A, Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A, Holding at Max. Rated Control Circuit Voltage DC 2 W, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A, Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Durée de fonctionnement nominaleEntre la mise hors tension de la bobine et la fermeture du contact NC (normally closed) 60 ... 130 ms, Entre la mise hors tension de la bobine et l'ouverture du contact NO (normally open) 55 ... 125 ms, Entre la mise sous tension de la bobine et l'ouverture du contact NC 27 ... 77 ms, Entre la mise sous tension de la bobine et la fermeture du contact NO 30 ... 80 ms
Connecting Capacity Main CircuitBar 30 mm², Flexible with Cable End 1 x 10 ... 70 mm², Rigid 1 x 10 ... 95 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible 2x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 2 x 1 .... 4 mm²
Indice de protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main PolesM8 hexagon socket screw with single connector
Type de borneCable Clamp

Technique UL/CSA

Maximum Operating Voltage UL/CSACircuit principal 600 V
Puissance nominale UL/CSA(200 V AC) Three Phase 30 hp, (208 V AC) Three Phase 30 hp, (220 ... 240 V AC) Three Phase 40 hp, (440 ... 480 V AC) Three Phase 75 hp, (550 ... 600 V AC) Three Phase 100 hp

Environnement

Température de l’air ambiantClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C
Altitude de fonctionnement maximale autoriséeWithout Derating 3000 m
Résistance aux chocs selon CEI 60068-2-27Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
Statut RoHSFollowing EU Directive 2011/65/EU

Pourquoi Proax pour ABB AM110-30-22-79?

Proax est un distributeur autorisé de ABB AM110-30-22-79 et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!

Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!

Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Informations complémentaires
Autres nomsAM110302279
Taille de l'emballage1
Recommandé

CAD$2,733.09

Pas en stock

Demandez un délai de livraison ou commandez - nous assurerons une livraison rapide

ABB Disponibilité