Démarreurs manuels
Cr101 Manual Motor-starting switches are designed for use with self-protected 1Ph & 3Ph motors, ON/OFF applications where overload protection is not required. 2HP//240Vac
Pas en stock
Cr101 Manual Motor-starting switches are designed for use with self-protected 1Ph & 3Ph motors, ON/OFF applications where overload protection is not required. 2HP//240Vac
Pas en stock
Cr101 Manual Motor-starting switches are designed for use with self-protected 1Ph & 3Ph motors, ON/OFF applications where overload protection is not required. 2HP//240Vac
Pas en stock
Cr101 Manual Motor-starting switches are designed for use with self-protected 1Ph & 3Ph motors, ON/OFF applications where overload protection is not required. 2HP//240Vac
Pas en stock
Cr101 Manual Motor-starting switches are designed for use with self-protected 1Ph & 3Ph motors, ON/OFF applications where overload protection is not required. 2HP//240Vac
Pas en stock
Signaling contacts SK1-AR with screw terminals signal the tripping of the manual motor starter.For SK1-AR a red flag in a window on the front of the device indicates the tripping event. The contact positions of SK1-AR don't need to be manually reset after a tripping. They are reset to their original position when the manual motor starter is switched back on. The SK1-AR signaling contacts signal tripping regardless if it was caused by short-circuit, overload or electrical release (AA1 or UA1). They are attached on the right side of the manual motor starter. Signaling contacts SK1-AR are available as normally open or normally closed contacts.
Pas en stock
Signaling contacts SK1-ARK with Push-in spring terminals signal the tripping of the manual motor starter. For SK1-ARK a red flag in a window on the front of the device indicates the tripping event. The contact positions of SK1-AR don't need to be manually reset after a tripping. They are reset to their original position when the manual motor starter is switched back on. The SK1-ARK signaling contacts signal tripping regardless if it was caused by short-circuit, overload or electrical release (AA1 or UA1). They are attached on the right side of the manual motor starter. Signaling contacts SK1-ARK are available as normally open or normally closed contacts.
Pas en stock
Signaling contacts SK1-ARK with Push-in spring terminals signal the tripping of the manual motor starter. For SK1-ARK a red flag in a window on the front of the device indicates the tripping event. The contact positions of SK1-AR don't need to be manually reset after a tripping. They are reset to their original position when the manual motor starter is switched back on. The SK1-ARK signaling contacts signal tripping regardless if it was caused by short-circuit, overload or electrical release (AA1 or UA1). They are attached on the right side of the manual motor starter. Signaling contacts SK1-ARK are available as normally open or normally closed contacts.
Pas en stock
Signaling contacts SK1-ARK with Push-in spring terminals signal the tripping of the manual motor starter. For SK1-ARK a red flag in a window on the front of the device indicates the tripping event. The contact positions of SK1-AR don't need to be manually reset after a tripping. They are reset to their original position when the manual motor starter is switched back on. The SK1-ARK signaling contacts signal tripping regardless if it was caused by short-circuit, overload or electrical release (AA1 or UA1). They are attached on the right side of the manual motor starter. Signaling contacts SK1-ARK are available as normally open or normally closed contacts.
Pas en stock
S2-M3-50 three phase feeder terminals allow the connection of cable cross sections up to 50mm². They are usable with MS165 manual motor starters. The rated current is 125 A (IEC) / 120 A (UL).
Pas en stock
CR1062 manual motor staters for small motors (1 -10HP) , Availible in 1,2,3Pole configurations for Open and NEMA type 1,3R, 4X enclosures.
Pas en stock
CR1062 manual motor staters for small motors (1 -10HP) , Availible in 1,2,3Pole configurations for Open and NEMA type 1,3R, 4X enclosures.
Pas en stock
Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 0.63 - 1.00 A, H×W×D 130 x 45 x 71 mm
Pas en stock
Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 11 - 16 A, H×W×D 130 x 45 x 71 mm
Pas en stock
Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 1 - 1.6 A, H×W×D 130 x 45 x 71 mm
Pas en stock
Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 14 - 20 A, H×W×D 130 x 45 x 71 mm
Pas en stock
Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 4 - 6.3 A, H×W×D 130 x 45 x 71 mm
Pas en stock
Motor Protection Circuit Breaker, Push-In Plus Terminals, Current setting range thermal overload release 0.10 - 0.16 A, H×W×D 130 x 45 x 71 mm
Pas en stock



















