SKU
MPN
1SFL427101R1411
Weight
2.19 kg
The AF116-40-11-14 is a 4 pole - 690 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and double clamp, controlling motors up to 55 kW / 400 V AC (AC-3) / and switching power circuits up to 160 A (AC-1) or 160 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Spécifications techniques

Dimensions

Produit Largeur Net120 mm
Produit Longueur Net128 mm
Produit Hauteur Net150 mm
Poids net2,05 kg

Technique

Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
TensionCircuit principal 690 V
Fréquence assignée (f)Circuit principal 50 Hz
Courant thermique conventionnel à l’air libre (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 160 A
Courant assignée d’emploi AC-1 (Ie)(690 V) 40 °C 160 A, (690 V) 60 °C 145 A, (690 V) 70 °C 130 A
Courant assignée d’emploi AC-3 (Ie)(415 V) 55 °C 116 A, (440 V) 55 °C 116 A, (380 / 400 V) 55 °C 116 A, (220 / 230 / 240 V) 55 °C 116
Puissance assignée d’emploi AC-3 (Pe)(415 V) 55 kW, (440 V) 75 kW, (380 / 400 V) 55 kW, (220 / 230 / 240 V) 30 kW
Pouvoir assigné de coupure AC-38 x Ie AC-3
Pouvoir assigné de fermeture AC-310 x Ie AC-3
Dispositif de protection contre les courts-circuitsgG Type Fuses 200 A
Courant assigné de courte durée admissible (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Tension assignée d’isolement (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 600 V
Tension assignée de tenue aux chocs (Uimp)Circuit principal 8 kV
Durabilite mecanique5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Plage d'utilisation de la bobine selon(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 250 ... 500 V, 60 Hz 250 ... 500 V, DC Operation 250 ... 500 V
Coil ConsumptionAverage Pull-in Value 50 Hz 260 V·A, Average Pull-in Value 60 Hz 260 V·A, Holding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A, Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A, Holding at Max. Rated Control Circuit Voltage DC 4 W, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 205 V·A, Pull-in at Max. Rated Control Circuit Voltage 60 Hz 205 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 230 W
Durée de fonctionnement nominaleEntre la mise hors tension de la bobine et l'ouverture du contact NO (normally open) 40 ... 70 ms, Entre la mise sous tension de la bobine et la fermeture du contact NO 20 ... 55 ms
Connecting Capacity Main CircuitFlexible 2 x 10 ... 70 mm², Rigid Cu-Cable 1 x 10 ... 95 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm², Flexible 2x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 2 x 1 .... 4 mm²
Indice de protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Type de borneDouble Clamp

Technique UL/CSA

Maximum Operating Voltage UL/CSACircuit principal 600 V
General Use Rating UL/CSA(600 V AC) 160 A

Environnement

Température de l’air ambiantClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C, Close to Contactor for Storage -40 ... +70 °C
Altitude de fonctionnement maximale autoriséeWithout Derating 3000 m
Statut RoHSFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Circular Value

Principes du Design Circulaire - Taux de RecyclabilitéConcu pour utiliser des ressources recyclables et réutilisables - Norme EN45555 - 87.8 %
ABB EcoSolutionsOui
Instructions relatives à la fin de vie1SFC100112M0001
Déchets destinés à l'enfouissement en décharge - DestinationDéchet non-dangereux mis en décharge, lorsqu’il n’existe aucune autre alternative à moins de 100km d’un bâtiment - Atteint
Amélioration de l'efficacité des ressources pour les clientsEfficacité du produit - Le produit nécessite moins d'énergie pour fonctionner par rapport à un produit similaire sur le marché. - Atteint

Eco Transparency

Environmental Product Declaration - EPD1SFC100092D0201

Pourquoi Proax pour ABB AF116-40-11-14?

Proax est un distributeur autorisé de ABB AF116-40-11-14 et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!

Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!

Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Informations complémentaires

Autres nomsAF116401114
Taille de l'emballage1
Recommandé

Pas en stock

Demandez un délai de livraison ou commandez - nous assurerons une livraison rapide

ABB Disponibilité