The CM-TCS.11P relay is from the CM temperature monitors range. This relay operates with a rated control supply voltage of 24 - 240 V AC / DC and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A. The CM-TCS.11P is able to measure temperature with 1 sensor circuit using PT100 sensor. The CM-TCS.11P monitors overtemperature, undertemperature and window monitoring with 2 thresholds. The corresponding threshold values are adjustable. The temperature measuring range is -50..+50°C. A sealable transparent cover for protection against unauthorized changes is available as accessory. The device offers maintenance free Easy Connect Technology with push-in terminals.
Spécifications techniques

Dimensions

Produit Largeur Net22,5 mm
Produit Longueur Net103,7 mm
Produit Hauteur Net85,6 mm
Poids net0,14 kg

Technique

FonctionOvertemperature monitoring, Undertemperature monitoring, Over- and undertemperature monitoring
Plage de mesure-50 ... +50 °C
Sensor TypePt100
Rated Control Supply Voltage (Us)24 ... 240 V AC/DC
Fréquence assignée (f)Supply Circuit 50 Hz, Supply Circuit 60 Hz, Supply Circuit DC
Sortie2 x 1 c/o or 1 x 2 c/o contacts, configurable
Type de borneBornes sans vis
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Courant assignée d’emploi AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Courant assignée d’emploi DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V, 10 mA
Tension assignée de tenue aux chocs (Uimp)Measuring Circuit / Output Circuit 4 kV, Output Circuit 1 / Output Circuit 2 4 kV, Supply Circuit / Measuring Circuit 4 kV, Supply Circuit / Output Circuit 4 kV
Tension assignée d’isolement (Ui)Measuring Circuit / Output Circuit 300 V, Output Circuit 1 / Output Circuit 2 300 V, Supply Circuit / Measuring Circuit 300 V, Supply Circuit / Output Circuit 300 V
Indice de protectionHousing IP50, Terminals IP20
Catégorie de surtensionIII
Degré de pollution3
Dispositif de protection contre les courts-circuitsOutput Circuit NC - F Type Fuses 6 A, Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Durabilite mecanique30000000 cycle
Connecting CapacityFlexible with Ferrule 2x 0.5 ... 1.5 mm², Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm², Flexible 2x 0.5 ... 1.5 mm², Rigid 2x 0.5 ... 1.5 mm²
Wire Stripping Length8 mm
Type d'encastrement1 ... 6
Montage sur rail DINTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Normes et standardsCAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 60255-27, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508

Technique UL/CSA

Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 2x 18-16 AWG, Rigid 2x 20-16 AWG

Environnement

Température de l’air ambiantOperation -40 ... +60 °C, Storage -40 ... +85 °C
Altitude de fonctionnement maximale autoriséeWithout Derating 2000 m
Statut RoHSFollowing EU Directive 2011/65/EU

Pourquoi Proax pour ABB CM-TCS.11P?

Proax est un distributeur autorisé de ABB CM-TCS.11P et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!

Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!

Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Informations complémentaires

Autres nomsCMTCS11P
Taille de l'emballage1
Recommandé

Pas en stock

Demandez un délai de livraison ou commandez - nous assurerons une livraison rapide

ABB Disponibilité