NSL... contactor relays are used for switching auxiliary circuits and control circuits. The NSL..S contactor relays are the spring terminal version of the NSL... range. - Poles and auxiliary contacts blocks: 4-pole contactor relays, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor relay side) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available NSL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
Spécifications techniques
Dimensions
Produit Largeur Net | 45 mm |
Produit Longueur Net | 72,5 mm |
Produit Hauteur Net | 68 mm |
Poids net | 0,28 kg |
Technique
Number of Auxiliary Contacts NO | 3 |
Number of Auxiliary Contacts NC | 1 |
Normes et standards | IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14 |
Tension | Circuit auxiliaire 690 V, Circuit principal 690 V |
Fréquence assignée (f) | Circuit auxiliaire 50 / 60 Hz |
Courant thermique conventionnel à l’air libre (Ith) | acc. to IEC 60947-5-1, q = 40 °C 10 A |
Courant assignée d’emploi AC-15 (Ie) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (400 / 440 V) 3 A |
Courant assigné de courte durée admissible (Icw) | for 0.1 s 140 A, for 1 s 100 A |
Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour, (DC-13) 900 cycles per hour |
Courant assignée d’emploi DC-13 (Ie) | (24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.27 A / 60 W, (250 V) 0.27 A / 68 W |
Tension assignée d’isolement (Ui) | acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V, acc. to UL/CSA 600 V |
Tension assignée de tenue aux chocs (Uimp) | Circuit auxiliaire 6 kV |
Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc) | DC Operation 24 V |
Durée de fonctionnement nominale | Entre la mise hors tension de la bobine et la fermeture du contact NC (normally closed) 15 ... 20 ms, Entre la mise hors tension de la bobine et l'ouverture du contact NO (normally open) 13 ... 17 ms, Entre la mise sous tension de la bobine et l'ouverture du contact NC 31 ... 53 ms, Entre la mise sous tension de la bobine et la fermeture du contact NO 36 ... 59 ms |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm², Rigid 1/2x 0.75 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm², Rigid 1/2x 0.75 ... 2.5 mm² |
Wire Stripping Length | Auxiliary Circuit 10 mm, Control Circuit 10 mm |
Indice de protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
Type de borne | Bornes à ressort |
Environnement
Température de l’air ambiant | Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
Altitude de fonctionnement maximale autorisée | Without Derating 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6 | 5 ... 300 Hz 3 g Closed position / 2 g Open position |
Résistance aux chocs selon CEI 60068-2-27 | Closed, Shock Direction: A 20 g, Closed, Shock Direction: B1 15 g, Closed, Shock Direction: C1 19 g, Closed, Shock Direction: C2 14 g, Open, Shock Direction: A 10 g, Open, Shock Direction: B1 5 g, Open, Shock Direction: C1 8 g, Open, Shock Direction: C2 8 g, Shock Direction: B2 10 g |
Statut RoHS | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
Pourquoi Proax pour ABB NSL31ES-81?
Proax est un distributeur autorisé de ABB NSL31ES-81 et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!
Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!
Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Informations complémentaires
Autres noms | NSL31ES81 |
Taille de l'emballage | 1 |
Meilleurs vendeursdans Contacteurs
- The AF26-30-00-13 is a 3 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 11 kW / 400 V AC (AC-3) or 15 hp / 480 V UL and switching power circuits up to 45 A (AC-1) or 45 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
- The AF16-30-10-13 is a 3 pole - 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 7.5 kW / 400 V AC (AC-3) or 10 hp / 480 V UL and switching power circuits up to 30 A (AC-1) or 30 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
- The AF30-30-00-13 is a 3 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 15 kW / 400 V AC (AC-3) or 20 hp / 480 V UL and switching power circuits up to 50 A (AC-1) or 50 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
- The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for standard industrial environments.Types of auxiliary contact blocks for front mounting:• CA4 1 or 4-pole block, with instantaneous N.O., N.C. contacts• CC4 1-pole block, with N.O. leading contact or N.C. lagging contact• CAT4 2-pole block, with instantaneous N.O. + N.C. contacts and A1 / A2 coil terminal connection on front face.Select the 4-pole auxiliary contact blocks CA4-..E, CA4-..M, CA4-..U or CA4-..N type, according to the contactor or contactor relay type for compliance with the standard requirements (see "Terminal marking and positioning").Types of auxiliary contact blocks for side mounting:• CAL4 2-pole block, with instantaneous N.O. + N.C. contacts.For clipping onto the right- and/or left-hand side of the contactors. The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function marking.
- The AF09-30-01-13 is a 3 pole - 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 4 kW / 400 V AC (AC-3) or 5 hp / 480 V UL and switching power circuits up to 25 A (AC-1) or 25 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
- The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for standard industrial environments.Types of auxiliary contact blocks for front mounting:• CA4 1 or 4-pole block, with instantaneous N.O., N.C. contacts• CC4 1-pole block, with N.O. leading contact or N.C. lagging contact• CAT4 2-pole block, with instantaneous N.O. + N.C. contacts and A1 / A2 coil terminal connection on front face.Select the 4-pole auxiliary contact blocks CA4-..E, CA4-..M, CA4-..U or CA4-..N type, according to the contactor or contactor relay type for compliance with the standard requirements (see "Terminal marking and positioning").Types of auxiliary contact blocks for side mounting:• CAL4 2-pole block, with instantaneous N.O. + N.C. contacts.For clipping onto the right- and/or left-hand side of the contactors. The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function marking.
- Connecting links with manual motor startersThe BEA insulated 3-pole connecting links are used to connect AF09 ... AF65 contactors with the MS116 or MS132 or MS165 manual motor starters. The BEA insulated 3-pole connecting links ensure the electrical and mechanical connection between the contactor and the associated manual motor starter. BPR65-4 35 mm rail hooks used with BEA65-4 connecting link, allow direct mounting on 2 rails 35 mm of MS165 manual motor starters with AF40 ... AF65 contactors.
- The VEM4 is a mechanical and electrical interlock set for the interlocking of two AF(C) contactors.VEM4 set includes a mechanical interlock unit VM4 with 2 fixing clips (BB4) and a VE4 electrical interlock block with A2-A2 connection.Fixing the electrical interlock block to the contactor front face connects the 2 built-in N.C. interlocking contacts with the two coils. VE4 block must be used with A2-A2 connection to respect the electrical connection diagram.
- The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for standard industrial environments.Types of auxiliary contact blocks for front mounting:• CA4 1 or 4-pole block, with instantaneous N.O., N.C. contacts• CC4 1-pole block, with N.O. leading contact or N.C. lagging contact• CAT4 2-pole block, with instantaneous N.O. + N.C. contacts and A1 / A2 coil terminal connection on front face.Select the 4-pole auxiliary contact blocks CA4-..E, CA4-..M, CA4-..U or CA4-..N type, according to the contactor or contactor relay type for compliance with the standard requirements (see "Terminal marking and positioning").Types of auxiliary contact blocks for side mounting:• CAL4 2-pole block, with instantaneous N.O. + N.C. contacts.For clipping onto the right- and/or left-hand side of the contactors. The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function marking.
- The AF65-30-00-13 is a 3 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 30 kW / 400 V AC (AC-3) or 50 hp / 480 V UL and switching power circuits up to 105 A (AC-1) or 90 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.