A 3-pole Contactor suitable for DC-1 applications where all three poles must be connected in series in a 1-pole configuration up to max 1000 VDC. Operated with wide control voltage range 100-250 V, AC/DC

Contactors for DC switching

GF, GAF, and GA contactors are engineered specifically for switching DC circuits up to 1500 V. These contactors are designed to efficiently break DC circuits, making them one of the most compact solutions on the market. Ideal for applications such as PV solar systems, EV charging stations, UPS, and energy storage systems. Additionally, ABB's standard AF contactor range is suitable for DC switching up to 850 V DC.

Product Benefits:

  • Compact and Modern: Space-saving design for efficient integration.

  • Global Compatibility: IEC and UL approved for worldwide use.

  • Reliable Performance: Suitable for diverse network environments.

  • Global Support: Access support and use the same products anywhere.

Product Features:

  • High Current and Voltage Handling:

    • Up to 1050 A, 1500 V DC-PV3 for PV solar applications.

    • Up to 2050 A, 1000 V DC-1 for other DC applications.

  • Proven AF Technology: GF and GAF contactors utilize reliable AF technology.

  • Versatile Control Voltage: Wide range from 100-250 V AC/DC.

  • Easy Integration: PLC interface with 24 V DC - 100 mA compatibility.

  • Built-in Protection: Surge suppression included for enhanced safety.

Spécifications techniques

Dimensions

Produit Largeur Net111,5 mm
Produit Longueur Net160 mm
Produit Hauteur Net196 mm
Poids net3 kg

Technique

Number of Main Contacts NO1
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
TensionCircuit principal 1000 V
Courant thermique conventionnel à l’air libre (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 275 A
Courant assignée d’emploi DC-1 (Ie)(1000 V) 3 Poles in Series, 40 °C 275 A, (1000 V) 3 Poles in Series, 55 °C 250 A, (1000 V) 3 Poles in Series, 70 °C 180 A, (220 V) 3 Poles in Series, 40 °C 275 A, (220 V) 3 Poles in Series, 55 °C 250 A, (220 V) 3 Poles in Series, 70 °C 180 A, (400 V) 3 Poles in Series, 40 °C 275 A, (400 V) 3 Poles in Series, 55 °C 250 A, (400 V) 3 Poles in Series, 70 °C 180 A, (600 V) 3 Poles in Series, 40 °C 275 A, (600 V) 3 Poles in Series, 55 °C 250 A, (600 V) 3 Poles in Series, 70 °C 180 A
Tension assignée d’isolement (Ui)acc. to UL/CSA 1000 V
Tension assignée de tenue aux chocs (Uimp)Circuit principal 8 kV
Durabilite mecanique5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Plage d'utilisation de la bobine selon(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V, 60 Hz 100 ... 250 V, DC Operation 100 ... 250 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A, Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A, Holding at Max. Rated Control Circuit Voltage DC 2 W, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 430 V·A, Pull-in at Max. Rated Control Circuit Voltage 60 Hz 430 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 500 V·A
Connecting Capacity Main CircuitBar 24 mm², Rigid Al-Cable 25 ... 150 mm², Rigid Cu-Cable 6 ... 185 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm², Flexible 2x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 2 x 1 .... 4 mm²
Indice de protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Type de borneMain Circuit: Bars

Technique UL/CSA

Maximum Operating Voltage UL/CSACircuit principal 600 V
General Use Rating UL/CSA(1000 V DC) 250 A, (440 V DC) 250 A, (600 V DC) 250 A

Environnement

Température de l’air ambiantOperation -40 ... +80 °C, Storage -40 ... +70 °C
Altitude de fonctionnement maximale autoriséeWithout Derating 3000 m
Résistance aux chocs selon CEI 60068-2-27Shock Direction: A 5 g, Shock Direction: B1 5 g, Shock Direction: B2 5 g, Shock Direction: C1 5 g, Shock Direction: C2 5 g
Statut RoHSFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Pourquoi Proax pour ABB GAF185-10-11-70?

Proax est un distributeur autorisé de ABB GAF185-10-11-70 et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!

Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!

Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Informations complémentaires

Autres nomsGAF185101170
Taille de l'emballage1
Recommandé

Pas en stock

Demandez un délai de livraison ou commandez - nous assurerons une livraison rapide

ABB Disponibilité