By ABB
SKU
MPN
1SCA121463R1001
Weight
1 kg
OTDC32F4 DC Switch-disconnector, Terminal bolt kit included, Handle and shaft need to be ordered separately, Base mounting, IEC 660 VDC 32 A double circuit, IEC 1000 VDC 20 A double circuit
Spécifications techniques
Circular Value
Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
REACH Declaration | 1SCC301240D0201 |
Informations RoHS | 1SCC301239D0201 |
Dimensions
Dimensions Cadre du produit | XS |
Produit Largeur Net | 52.5 mm, 2.1 in |
Produit Hauteur Net | 89 mm, 3.5 in |
Produit Longueur Net | 89 mm, 3.5 in |
Poids net | 0.2 kg, 0.5 lb |
Technique
Rated Operational Current DC-21B (Ie) | (660 V) 32 A, (1000 V) 20 A |
Courant thermique conventionnel à l’air libre (Ith) | q = 40 °C 45 A |
Conventional Thermal Current (Ithe) | Fully Enclosed 45 A |
Tension assignée de tenue aux chocs (Uimp) | 8 kV |
Tension assignée d’isolement (Ui) | 1000 V |
Tension | 1000 V |
Rated Short-Circuit Making Capacity (Icm) | (1000 V DC) 0.8 kA |
Courant assigné de courte durée admissible (Icw) | (1000 V DC) 0.8 kA, for 1 s 0.8 kA |
Power Loss | at Rated Operating Conditions per Pole 0.5 W |
Degré de pollution | 3 |
Handle Color | Noir |
Handle Type | Knob handle |
Positive Opening Operation Torque (Direct Opening Action) | 0.4 … 0.8 N·m |
Diamètre d'arbre | 6 mm, 0.24 in |
Switches Operating Mechanism | Mechanism on Top of the Switch |
Position of Line Terminals | Top In - Bottom Out, Bottom In - Top Out |
Mode de fonctionnement | Front Operated |
Normes et standards | IEC 60947-1, -3 |
Fonctions spéciales | Non |
Type de montage | Base mounting, DIN-rail mounting |
Number of Circuits | 2 |
Nombre de pôles | 4 |
Section de câble | 2.5 ... 16 mm² |
Indice de protection | Front IP20 |
Type de borne | Bornes à vis |
Couple de serrage | 1.2 … 1.4 N·m |
Utilization | Photovoltaic |
Utilization Category | Switching of resistive loads, including moderate overloads - occasional actuation (DC-21B) |
Technique UL/CSA
Couple de serrage | 1.2 … 1.4 N·m |
Environnement
Statut RoHS | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Pourquoi Proax pour ABB OTDC32F4?
Proax est un distributeur autorisé de ABB OTDC32F4 et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!
Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!
Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Informations complémentaires
Taille de l'emballage | 1 |
Recommandé
- A fully optimized four-pole DC switch-disconnector for 1000V utility-scale photovoltaic power plants covering 315-630A current range. The new design offers both a size reduction and an increase in efficiency and performance. The four-pole 1000V DC Switch helps manufacturers improve system efficiency. The compact size of the new OTDC range makes it possible for manufacturers to reduce the size of combiner boxes and inverters.Main characteristics for this switch:Disconnect double PV circuit, Approved according to UL98B and IEC 60947-1,-3
- A fully optimized two-pole DC switch-disconnector for 1000V utility-scale photovoltaic power plants covering 315-630A current range. The new design offers both a size reduction and an increase in efficiency and performance. The two-pole 1000V DC Switch helps manufacturers improve system efficiency. Measuring just 150mm wide and 122mm high, the compact size of the new OTDC range makes it possible for manufacturers to reduce the size of combiner boxes and inverters.Main characteristics for this particular OTDC type:Disconnect single PV circuit, Approved according to UL98B and IEC 60947-1,-3
- A fully optimized two-pole DC switch-disconnector for 1500V utility-scale photovoltaic power plants covering 315-630A current range. The new design offers both a size reduction and an increase in efficiency and performance to help manufacturers adapt to the industry’s rapid adoption of 1500V DC solutions.The two-pole 1500V DC concept helps manufacturers improve system efficiency, reducing switch losses by up to 35 percent. Measuring just 150mm wide and 122mm high, the OTDC range of 1500V DC switches is also up to 30 percent smaller than conventional solutions. The compact size of the new OTDC range makes it possible for manufacturers to reduce the size of combiner boxes and inverters.Main characteristics for this particular OTDC type:Disconnect single PV circuit, Approved according to UL98B and IEC 60947-1,-3
- ABB offers new OTDC Switch-disconnectors specially designed for reliable switching for ESS applications were higher performance is needed. They are durable and virtually maintenance-free, and offer easy installation for all imaginable situations.Depending on the ESS layout and the customer’s wishes, the OTDC switch-disconnectors may be used in one or more sections of the overall setup, for the battery protection.Main characteristics of this particular OTDC type:Rated conditional short circuit current with fuses is 30kA, 2-Pole, 1500Vdc, Approved according to UL98B and IEC 60947-1,-3