By ABB
SKU
MPN
1SCA135141R1001
Weight
1.252 kg
3-pole, front operated, door mounted switch-diconnector with protected clamp terminals and with black IP65 handle and shaft
Spécifications techniques
Circular Value
Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
REACH Declaration | 1SCC011021D0201 |
Informations RoHS | 1SCC011020D0201 |
Dimensions
Produit Largeur Net | 123 mm |
Produit Hauteur Net | 130 mm |
Produit Longueur Net | 75 mm |
Poids net | 0,9 kg |
Technique
Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 160 A, (500 V) 160 A, (690 V) 160 A |
Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 160 A, (500 V) 160 A, (690 V) 160 A |
Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 160 A, (500 V) 160 A, (690 V) 160 A |
Rated Operational Power AC-23A (Pe) | (220 ... 240 V) 45 kW, (400 ... 415 V) 75 kW, (500 V) 90 kW, (690 V) 132 kW |
Courant thermique conventionnel à l’air libre (Ith) | q = 40 °C 160 A |
Conventional Thermal Current (Ithe) | Fully Enclosed 160 A |
Tension assignée de tenue aux chocs (Uimp) | 12 kV |
Tension assignée d’isolement (Ui) | acc. to IEC/EN 60664-1 1000 V |
Tension | Circuit principal 1000 V |
Rated Short-Circuit Making Capacity (Icm) | (690 V) 12 kA |
Courant assigné de courte durée admissible (Icw) | for 1 s 4 kA |
Rated Conditional Short-Circuit Current (Inc) | (200 A fuse, 500 V) 100 kA, (200 A fuse, 690 V) 50 kA |
Power Loss | at Rated Operating Conditions per Pole 6.5 W |
Degré de pollution | 3 |
Handle Color | Noir |
Handle Type | Handle and shaft included |
Switches Operating Mechanism | Mechanism at the End of the Switch, 03 (Left Side) |
Distance Between Phases | Standard |
Position of Line Terminals | Top In - Bottom Out, Bottom In - Top Out |
Mode de fonctionnement | Front and side operated |
Normes et standards | IEC 60947-3 / UL 98 / CSA C22.2 NO.4 |
Fonctions spéciales | Non |
Type de montage | Montage de la porte |
Nombre de pôles | 3 |
Section de câble | Cu 10 ... 70 mm² |
Indice de protection | Front IP20 |
Type de borne | Bornes à vis |
Couple de serrage | acc. IEC 60947-1 6 N·m |
Durabilite mecanique | 20000 |
Lock Type | Oui |
Technique UL/CSA
Maximum Operating Voltage UL/CSA | 600 V |
Ampere Rating | 125 A |
Puissance nominale UL/CSA | (240 V AC) Single Phase 20 Hp, (440 ... 480 V AC) Single Phase 30 Hp |
Couple de serrage | acc. IEC 60947-1 6 N·m |
Tightening Torque UL/CSA | 53 in·lb |
Environnement
Statut RoHS | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Pourquoi Proax pour ABB OT160GT03P?
Proax est un distributeur autorisé de ABB OT160GT03P et l'un des plus grands distributeurs de ABB en Amérique du Nord. Notre équipe technique interne, qui est hautement qualifiée, est prête à répondre à vos besoins techniques!
Avez-vous une question? pour vous aider à obtenir le bon produit le plus rapidement possible pour votre projet. Nous sommes toujours là pour vous aider!
Délai de livraison court
Personnel qualifié
Chat en direct
Support technique
Inventaire local
60+ ans d'expérience
Informations complémentaires
Taille de l'emballage | 1 |
Recommandé
- OT switch-disconnectors are suitable for a wide range of demanding applications such as machinery, power distribution, switchboards and motor control center installations. These devices are globaly available and comply with all relevant standards. The complete OT range is available from 16A to 4000A for IEC and 16A to 2000A for UL market. Thanks to their modular structure from 160A and upward, they also help to create purpose-built solutions with the right pole configuration and can be equipped with direct mount handles or side-operated. The smart design eliminates also the need of major customization for busbar connections which saves costs. The switches can be found in both manual and motorized applications. The complete range also include a comprehensive range of inbuilt safety features and offers snap-on accessories that saves installation time and costs.
- Encl. Switch Disconnector, 4-p. 415V AC23 160A, 88kW. Plastic enclosure. IP65. Black Pistol handle. Interlocked cover. Defeatable interlocking. The enclosure in the OT series is using a rigid glass reinforced polycarbonate enclosure. The enclosure is UV protected, protected against low-pressure water jets (IP65), and hence built for outdoor and indoor use. The cable entries knock out types for II-flanges. Cables can be inserted from top and bottom. The handle is padlockable and made for three padlocks. The cover is interlocked. The interlocking can be defeated. N and PE terminals included.
- Safety switch, 3-p. 415V AC23 160A, 80kW. Mounted auxiliary contact: 2NO1NC. Stainless steel enclosure. IP65. StainlessSteel Pistol handle. Interlocked cover. Defeatable interlocking. The enclosure and handle of the OT series is made of rigid acid proof steel, class AISI316L. The enclosure has a hinged door, with door lock. The cover is interlocked, and can not be opened when switch is on. The interlock function can be defeated for thermographing. The cover has also a gas pressure releaf function, to protect the user in case of internal arc. Suitable for outdoor and indoor use. The cable entries holes are prepared for cable flanges. The cable flanges (KOT61007 or KOT62296 (for EMC)) and the covers for the holes (KOT61008), have to be bought separately. The switch can be used in EMC applications, if EMC ring flanges are used. PE terminals and auxiliary contacts are included.